My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15356
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15356
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2015 1:19:16 PM
Creation date
6/23/2015 1:19:12 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
14-15356
Building Department - Name
SUNRISE PROPERTIES OF ZEPHYRHILLS INC
Address
6520 FORT KING RD UNIT 4-8
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BXUV.U495-Fire-resistance Ra6ngs-ANSI/UL 263 ` <br /> DMFCW BS L L G—P'roSTUD <br />, MBA BUILDTNG SUPPLIES INC— ProSTUD <br /> RAM SALES L L C— Ram ProSTUD' <br /> SOUTHEASTERN STUD&COMPONENTS INC=ProSTUD <br /> STEEL STRUCTURA L SY5fEM5 L L C—Tri-S PrbSTUD <br /> 2C. Framing Members*-Steel Studs— Not shown - In lieu of Item 2 — For use vuith Item 1C, proprietary <br /> channel sliaped steel studs, 1-1/4 in, deep by min 3=5/8 in. wide fabricated from min.0.020 in. thick galy <br /> steel. Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max. <br /> TELLING INDUSTRIES L LC—Viper20T"' <br /> 2D. Framing,Members*—Steel Studs— Not shown -In Ileu of Item 2 — For use with Item 1D, channel <br /> shaped steel studs, 1-1/4 in. deep by min 3-5/8 in. wfde fatirlcated from min 0.018 (n. thick gaiv steel. <br /> Studs cut 3/8 in. less in length than assembly height. Spaced 24 in. OC max. <br /> TELLING INDUSTRIES L L C—TRUE-STUDT" <br /> 3..Batts and-Blankets*— (Optional, not shown) — Mineral wool or glass fiber batts partially or completely <br /> I filling stud cavity. <br /> See Batts and Blankets (BZJZ) category for names of Classified companles. <br /> 3A. Fiber,Spray,ed*—As ari alternate to Batts and Blankets (Item 3) — (100% Borate Formulation) —Spray <br /> applied cellulose materiaL The fi6er is applied with water to completely flll the enclosed cavlty in accordanc'e <br />, with the application instructions supplied with the product with a nominal dry density of 2J Ib/ft3. Alternate <br /> Application Method: The fiber is applied without water or adhes.ive a.t a nominal dry density of 3.5 Ib/ft3, in <br /> accordance with tfie application Instructfons supplled wi#h the product. <br /> U S GREENFIBER L LC— IN5735 &INS745 for use witfi wet or dry application. IN5765LD and INS770LD are to <br /> be used for dry application only. <br /> 3B. Fiber,Sprayed*—As an alternate to Batts and Blankets (Item 3) and Item.3A- Spray applied cellulose <br /> insulation material.The fiber is applied with water to interior surtaces in accordance with the application <br /> instructions supplied with the product. Applied to com.pletely fill the enclosed cavity. Minimum dry density of <br /> 4.3 Pounds per-cublc ft. <br /> NU-WOOL CO INC—Cellulose Insulatfon <br /> 3C. Fiber,Sprayed*—As an alternate to Batts and Blankets (Item.3) - Spray applied celiulo"se fibe�: The <br /> . fiber is applied with water to completely fill the enclosed cavity in accordance with the application iristructions <br /> supplied with the product.The minimum dry density shall b.e 4,30 Ibs/ft3. <br /> INTERNATIO{IVALCELWLOSE CORP —Celbar-RL <br /> 4: Screws—Type 5 self-tapping screws, 1-1/4 or 2 in. long, {1 Hr) and 2-1/2 in. long (2 Hr). <br /> 5. Building Units*— For 1 Hr Rating— Nom 5/8 or 3/4 in. thick, 4 ft wlde, faced gypsum board panels with <br /> the faced side on the interiorwall cavity. Panels attached to studs and floorand ceiling runners with screws <br /> spaced 8 in, OC along the edges of the panel and 12 in. OC in the field of the panel. Joints oriented <br /> vertically and staggered on opposite sides of the assembly. <br /> MOMENTIVE PERFORMANCE MATERIAlS—Type CoreGuard. <br />� 6. ]oint Tape and Compound— (Not Shown) —Vinyl, dry or premixed joint compound, applied in two coats to <br /> joints-and screw heads; paper tape, 2 in. wide, embedded in first la_yer of compound over all joi�ts. <br /> 7. Gypsum Board*— For 2 Hr Rating —Any 5/8 in.thick UL Classified Gypsum Board that Is eligible for use <br /> in Design Nos:L501;G512 or U305, Nom. 5/8 fn. thlck, 4 ft wide, gypsum board applied over exterior face of <br /> http:!/database.ul.com/cgi-bin/XYVftemplatefLISEXT/1 FRAME/showpage.html?name=6XUV.U495&ccnshorttitle=Fire-resistancetF�ti��g�'F�i..4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.