4.,,,,,� NAIL FIN INSTALLATION <br /> 12'O.C.YA7f. FROM <br /> TfIRU JAMB�COWIERS <br /> 1°M1t2N.EMBEDAtENT <br /> z•.a•or nw:o�ry MIN.DISTANCE <br /> � � <br /> �Y o.a o-- MIIJ.DSSTANCE FOR EDGE:5/16" <br /> 11A7(.iHRU FOR EDGE:5/16" 1/4°MAX <br /> �� SHIM SPACE <br /> tia°Mnx 2"x4"or <br /> SHIM SPACE masonry <br /> 12'o.a FRAME SECI'ION(TYP) 1"MIN. JJ�� <br /> VERTICALSECTION EMBEDMENT � � <br /> � / ti w,�,�,aa,..a,��nw.awwow.q <br /> � <br /> ♦'O.F <br /> 6 <br /> _ �'O.C. � <br /> 3 CENTER <br /> � 12'O.R � O <br /> � 7AMB SECTION(ll'P) <br /> HORIZONTAL SEC7ION <br /> NOTE:Caulk beiween Nwing Flonge 6 Waod Opcnlrg. <br /> e <br /> va•.�ux <br /> SHIM SPACE <br /> � MIN.DISTANCE BUILDERS VINYL DOUBLE HUNG <br /> FOR ED6E:5/16° <br /> ���oW���-��_I Z•x4•o �nry Max Frnme DP RATING IMPACT <br /> TYPICAL ELEVATION WITH FASTENER SPACING �"A+�+E��M�� 38 x 74 i'I—r'JO NO <br /> Installation Notes: General Notes: <br /> 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria of <br /> 2. Use#8 X 1 1/4"PH or greater fastener throught the nail fin with sufficient length to penetrate a the adopted International Building Code(IBC),the Intemational Residential Code(IRC),the Florida <br /> minimum of 1"into the wood framing. For iwo(2X)wood frame substrate(min.S.G.=0.42). Building Code(FBC)and the industry requirement for the stated condi6ons. <br /> 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. <br /> to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is single strength annealed insulated glass. <br /> project of installation. 4. Use structural or composite shims where required. <br /> 5. Installation methods can be interchanged within ihe same opening. <br /> 6. An impact protective system is required where wind borne debris protection is mandated by local <br /> This schedule addresses only the fasteners required to anchor the building code. <br /> window to achieve the rated design pressure up to the size limitations 7, Maximum sizes are buck sizes and do not include fin or flange. <br /> noted. Il is not intended as a guide to the installation process and does PROIECT ENGINEER: DATE: <br /> not address he sealing consideration that may arise in different wall -- 11/16/2012 3250 Lakeport Blvd <br /> conditions. For the complete installation procedure,see the instructions oanwri er: scn�E: Klamath Falls,OR.97601 <br /> D.Vezo NTS Phone: (541)882-3451 <br /> packaged with the window or go to CHECKED BY: TITLE: <br /> www.jeld-wen.com/resourcesfinstallation. J. Kantola <br /> DISCLAIMER: APPRO��oBY: Builders�nyl Double Hung Window <br /> This-drawing and its contents are confidential and are not to be a arr�o ecr No: Nail Fin Installation(38"x 74") <br /> reproduced or copied in whole or in part or used or disclosed to others AS TESTED �6U�3�� <br /> BXC2 t 8S BUtIIOfIZBd b �ELD-WEN If1C. IDENTIFIER No. PLANT NAME AND LOCqTION: CAD DWG.No.: REV: SHEEf <br /> P y SJW2012-169-F C �� �oFz <br />