Laserfiche WebLink
� Y ' � <br /> _� The Association of • <br /> v � Poo/&Spa Professionals° � , <br /> ANSUAPSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS <br /> PROJECE NAME: WHITE CONTRACfOR NAME CHALLENGER POOLS <br /> AND ADDRESS AND ADDRE55: <br /> 6832 STEPHENS PATH 6846 N DALE MABRY HWY <br /> ZEPHYRHILLS FL 33542 TAMPA FL 33614 <br /> owNeR:KEVIN AND JANICE coNrRacroR PHONe:�813)886-9119 o"TE'6/9/2014 <br /> This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa <br /> Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only.Contredors should acquire and comply <br /> with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org. <br /> 1. §5.2.1:Calculated pool volume <br /> a. Gallons: 8�4B2 ;or 1, 8,482 gallons _ <br /> b.Calculated Gallons: 25z (surface area)X 4•5 (average depthJ X 7.48 (gal/ft^3J = 8�482 <br /> 2.§5.2.1:Calculated maximum filtration flow rate 2• 36 gPm _ <br /> (Pool volume=360 or 36gpm whichever is largerJ <br /> 3.§5.2.2:Auxiliary Pool Load: �Yes,�,No? <br /> (Enter the highest'auxiliary pool lood"to be powered by the swimming pool fritration pump.Do not add auxiliary 3. 3o gPm _ <br /> pool load flow rates together,only the highest is used.J <br /> 4. Calculated maximum flow rate 4. 36 gpm <br /> (Item 2 oritem 3,whicheveris larger.) <br /> 5.§5.5.1:Pipe sizing: <br /> a.Minimum suction pipe diameter 5a. �•5 inches <br /> (Enter the smallest pipe size from Tab/e 1 with a 6 fps flow capacity the same or more than item 4.) <br /> b. Minimum suction branch pipe diameter 5b. 1•5 inches <br /> (Calculote:Item 4. 36 (gpmJ=Branch Pipes � (quontityJ=branch flow rate 36 (gpmJ. <br /> Enter the smalfest pipe size from Table 1 with a 6 fps Jlow capacity the same or more than the calculated <br /> suction branch flow rate.) <br /> c.Minimum return pipe diameter 5c. 1•5 inches <br /> (Enter the smallest pipe size fram Tab/e 1 with a 8 fps flow capocity the same or more than item 4.J <br /> d. Minimum return branch pipe diameter 5d. �•5 inches <br /> (Calculate:Item 4. 36 (gpmJ=8ranch Pipes � (quantity)=branch f/ow rate 36 (gpmJ. <br /> Enter the smallest pipe size from Table 1 with a 8 fps f/ow capacity tAe same or more than the calculated <br /> return branch}low rate.) <br /> 6.§5.4.1:Filter type and size: <br /> a.Filter type:(Cartridge, DE,SandJ 6a. Cartridge <br /> b. Minimum filter area 6b. 96•� sq.ft. — <br />, (Cakulate:item 4. 36 (gpmJ=fi/ter foctor �•375 ) <br /> Filterfactors:Cortrid e=0.375, Sand=15,DiatomaceousEarth=2 <br /> 7. §5.4.2:Backwash valve: �Yes, �No? 7, 2•o inches — <br /> (When using a backwash valve,enter resu/t of item 5c or 2 inches wflichever is largerJ <br /> Table 1 �n ;siY�Pipe;si�e: -��1:9'.; s.��.�.x_x5��. �;3��, «; ,; ��.u,, x6";:.; <br /> �;3:5,., '4:� :5"a�;: <br /> �...... .._...__ _ _�... : . ..... ...... . __..., <. . , . _.. .... .... <br /> Nominal GPM�6 fps„ 38 63 90 138 185 238 374 540 <br /> Nomina6GPM @ 8 ips'' S1 84 119 184 247 317 499 720 <br /> 8.Pump selection: <br /> §5.3.2.1:Pools 17,000 gallons or less,select pump*from the dotabase with o Curve-A gpm flow equal to item 2 or less. <br /> §5.3.2.2:Pools 17,001 gallons ormore,select pump*from the datobose with a Curve-Cgpm flow equal to item 2 orless.*Multi- <br /> speed pumps must have one speed listed thatsatisfies this requirement. <br /> a.Pump model ga, WFDS-24 <br /> b.Pump flow Sb. 34 gpm <br /> (§5.31.1,5.3.2.2:Applicable Curve A or C gpm flow listed in databosef <br /> 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2 <br />� <br />