STEEL DECK SYSTEM LIMITATIONS: <br /> 1. If inechanicAl attachment to the structural deck through the lightweight insulating cancrete is proposed, a field <br /> withdrawal resistance testing shall be performed to determine fastener patterns and density. Atl testing and fastening <br /> design shall be in compliance with T'esting Application Standard TAS l05 and Roofing Application Standard RAS <br /> U 7 und/or RAS 137, calculations shall be signed And sealed by a Florida registered Professional Engineer, <br /> Registered Architect,or Registered Roof Consultant. <br /> 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage <br /> attached with 5/8"puddle welds with weld washers at every flute with maximum deck spans of 5 ft.o.c. <br /> GENERAL LIMITATIONS: <br /> l. Fire ctassification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire <br /> ratings of this product. <br /> 2. Insulation may be instatled in multiple layers. The first layer shall be attached in compliance with Product Gontrol <br /> Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt appiied within the <br /> EVT range And at a rate of 20-40 Ibs./sq.,or mechanicatty attached using the fastening pattern of the top layer <br /> 3. Alt standard panel sizes are acceptable for mechanical uttachment. When applied m approved asphalt, panel si�e <br /> shall be 4'x 4'maximum. <br /> 4. An overlay andlor recovery board insulation panel is required on all applicAtions over closed cell foam insulations <br /> when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping <br /> with Approved asphalt, 12" diameter circles. 24" o.c.;or strip mopped 8" ribbons in three rows, one at e�h sidelap <br /> and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not <br /> acceptable. A 6" break shall be pluced every 12' in eac�h ribbon to allow cross ventilation. Asphalt application of <br /> either system shall be at u minimum rate of l2 Ibs./sq. Note: Spot attached systems shall be limited to a <br /> maximum design pressure of-4S psf. <br /> 5. Fastener spacing for insulntion attachment is based on a�vtinimum Characteristic Force(F')value of 275 Ibf.,as <br /> tested in comptiance with Testing Application Standard TAS lOS. If the fastener value,as field-tested,are below <br /> 2751bf. insulation attachment shall not be acceptable. <br /> 6. Fastener spacing for mechanical attachment of unchor/base sheet or membrane attachment is based on a minimum <br /> fas►ener resistance value in conjunction with the maximu;m design value listed within a specific system. Should the <br /> fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, <br /> prepared,signed and sealed by a Florida Registered Engi�eer,Architect,or Registered Roof Consultant may be <br /> submitted. SAid revised fastener spacing shall utilize the withdrawal resistance value tnken from Testing <br /> Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. <br /> 7. Perimeter tand comer areas shall comply with the enhat�ced uplift pressure requirements of these areas. Fastener <br /> densities shall be increased for both insulation and base sheet as calculated in compliAnce with Roofing Applicupon <br /> Standard RAS 117 und/or RAS 137. (When this limitatioa is specifcally referred within this NOA, General <br /> Limitation#9 will not be applicable.) <br /> 8. All attachment aad sizing of perimeter nailers,metal profile,undlor flashing terminution designs shall conform with <br /> Roofing Application Standard RAS 111 And applicable wind load requirements. <br /> 9. The maximum designed pressure limitation listed shall b�applicable to ail roof pressure aones(i.e. field,perimeters, <br /> and corners).Neither rationul analysis,nor extrapolation shal(be permitted for enhanced fastening at enhanced <br /> pressure zones(i.e.perimeters,extended comers and corners).(When this limitation is specifically referred <br /> within this NOA,General Limitation#7 will not be appticable.) <br /> 10. All products listed herein shall have a quality assutance audit in accordance with the Florida Building Code and <br /> Rule 9N-3 of the Florida AdministrAtive Code. <br /> END OF THIS ACCEPTANCE <br /> NOA No.: 13-0411.04 <br /> �� Expiration Date: 08l31/t4 <br /> .. • ► <br /> Approval Date: 08/29/13 <br /> Page 18 of 18 <br />