Laserfiche WebLink
l � , <br /> TFP515 � <br />' Page 6 of 8 <br /> RUN <br /> TO WET SIDE ���� FACE OF � - <br /> SYSTEM OUTLET O PLUGGED SFfiINKLER <br /> PLUGGED FITTING I <br /> / SPRINKLER <br /> � FITTING <br /> YSTEM (SEE DESIGN � DCPOSURE <br /> CRITERIA LENGTH <br /> -- SECTION) ' '" (SEE DESIGN <br /> SPRINKLER CRITERIA <br /> INTENDED FITTING DSB-2 INT�ENDED SECTION) <br /> - (SEE DESIGN � INTENDED <br /> FOR FREEZER EOR FREEZER - <br /> STRUCTURES . - CRITERIA - FOR FREEZER STRUCTURES <br /> SECTION) • - -�- STRUCTURES <br /> � <br /> F/GURE 5 F/GURE 6 <br /> SPRINKLEfi FITTlNG SPRlNiCI:ER�FlTTING FlGURE 7 <br /> HEATED AREA UIVhIEATED AREA EXPOSURE LENGTH <br /> STRAP TIES Absence of the Cover Rlate As's`embly during,and after installation.Sprinklers <br /> (ENDS ON may delay sprinkler oPeration in a fre clamaged by droppirig,striking,wrench <br /> OPPOSING situation. twist/slippage, or the like, must be <br /> SIDES OF A Vent Hole is provided in the Bulb replaced. Also, replace any sprinkler <br /> BOO� Seat Fi ure 1 to indicate if the Dr that tias a cracked bulb or that has lost <br /> � g � y li uid from if"s bulb. 'Ref, installation <br /> DSB-2 BOOT Sprinkler is remainirig dry. Eviclence Section.) ( <br /> of leakage from the Vent Hole indicate <br /> ADHESIVE potential leakage past the Inlet seal If a sprinkler must be removed,do not <br /> and the need to remove the sprinkler reinstall it or a replacement _without <br /> 2-1/2"DIA. to determine the.cause of leakage;for reinsfalling the Cover Plate Assembly. <br /> (63,5 mm) example, an improper installation or If a Cbver Plate 'Assembly becomes <br /> � CLEARANCE an ice plug. Close the fire protection dislodged during service, replace it <br /> HO�E system control valve and the system immecliately. <br /> INSULATED drain before removing the sprinkler. rne owne� is responsible for the <br /> FREEZER When properly installed, there is a inspecfion,testing,and maintenance of <br /> STRUCTURE nominal 3/16 inch (4,8 mm) air gap their fre protection system arid deyices <br /> DS-C between #he lip of the Cover Plate in compliance with this document, as <br /> DRY PENDENT and the ceiling,as shown in Figure 2. well as with tfi`e applicable standards of <br /> CONGEALED Tiiis air gap is necessary for proper the National Fire Protection A§'sociation <br /> SI'RINKLER operation of the sprinkler. If the ceiling (for example, NFPA 25), in acldition to <br /> � is to be repainted after the ins#allation the standards of any other Authorities <br /> FIGURE 8 of the Sprinkler,care must be exe�cised Havi,ng Juriscliction. The installing <br /> MODEL_DSB-2 to ensure that the new paint does IVOT contractor or sprinkler manufacturer <br /> DRY SPRlIVlCLER BOOT seal off any of tlie air gap. shoulcl" be contacted rela#ive to any <br /> WITH DRY-TYPE SPRINKLER Do not pull the Cover,Plate relative to 4uestions. <br /> the�Enslosure.Separation may result. Automatic sprinkler systems are recom- <br /> Care and Sprinklers which are found to be mended to be irispected,testecl, and <br /> = � ° -'°-' Ieaking or exhibiting visible signs of maintained by a qualified lospection <br /> M � � Service in accordance wifh local <br /> a�ntenance corrosion must be replaced. requirements and%r national codes. <br /> TYCO Series DS-C Dry Type Concealed Automatic sprinklers must never be <br /> Pendent Sprinklers must be maintained Painted, plated, coated, or otherwise <br /> and serviced in accordance with this altered after leaying the factory. <br /> section. Nlodified sprinkler's must be replaced. <br /> SPririklers tYiat tiave been exposecJ to <br /> Before closing a fire protection system corrosive products of combustion,but <br /> main control valve for maintenance have not operated,should be replaced <br /> work on the fire protection system if they cannot be completely cleaned <br /> that it controls, obtain permission to by wipin.g the sprinkler with a cloth or <br /> shut down the affected fire protection by.brushing it with a soft bristle brush. <br /> systems from the proper.authorities Care must be exercised to avoid <br /> and notify all personnel who may be damage to the sprinklers - before, <br /> affected by this action. <br />