My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15513
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15513
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2015 11:44:16 AM
Creation date
8/18/2015 11:44:14 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
14-15513
Building Department - Name
SYNC II LLC
Address
6830 GALL BLVD BLD B 101
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� STANDARD LOAD OUTPUTS <br /> Company Name: 04-21-14 <br /> Block Load v1.0 Page 1 <br /> �**�:�**�r*�***�***�r�r�****�r*��**********�*****************�r�*�*�*********� <br /> Zone Name: FMC GALL WEST/SO <br /> City Name : TAMPA *, FLORIDA Weight - Wall: 30 <br /> Latitude (deg) : 28 {lb/sqft) Roof: 40 <br /> Elevation (ft) : 35 Bldg: 30 <br /> Indoor -Summer: 74 F SO RH Color - Wall : LIGHT <br /> -Winter: 72 F Roof: LIGHT <br /> ------------------------------------------------------------------------ <br /> TEMP TOTAL TONS RSH TONS CFM <br /> 1. JAN at 8 A.M. 67 .2 1.54 1 .19 681 <br /> 2 . FEB at 9 A.M. 71_2 2 .00 1.54 882 <br /> 3 . APR at 10 A.M. 78 .6 2 .37 1.66 955 <br /> 4. MAY at 2 P.M. 91.0 3 .58 2 .66 1, 525 <br /> 5_ JUN at 5 P.M. 92 .0 4.62 3 .56 2, 044 <br /> 6 . AUG at 5 P.M. 93 .0 4.75 3 .69 2,117 <br /> 7_ NOV at 11 A.M. 77_6 2 .75 2 .07 1, 189 <br /> Heating Load {Btuh) = 24,413 w/Infil.= 24,413 Airflow= 584 cfm <br /> ------------------------------------------------------------=----------- <br /> ORIENTATION OF BUILDING N S E W RF <br /> TRANSMISSION FACTORS 0.14 0.14 0.14 0 .14 0.05 <br /> Glass Fac. :1.13 Lights Fluorescent? Y Shade Fac. :0 .65 Floors: 1 <br /> Length: 17 Width: 64 Height: 10 Vent Air Percent: 13 <br /> ------------------------------------------------------------------------ <br /> Number of people = 12 Sensible people load = 2, 962 <br /> Total lights = 1,523 Lighting load = 6,498 <br /> Other electrical = 544 Other electrical = 1, 857 <br /> Area of N glass = 0 North glass solar = 0 <br /> Area of S glass = 96 South glass solar = 624 Z m�N <br /> Area of E glass = 0 East glass solar = 0 � �,��, <br /> Area of W glass = 189 West glass solar = 19, 362 ! Q s�z <br /> Total glass area = 285 Total glass solar = 19, 986 0�..- <br /> Total glass t'rans. = 6, 119 Q ��,,° � <br /> Area of N wall = 170 N wall load = 476 0�o � <br /> Area of S wall = 74 S wall load = 245 ��m <br /> Area of E wall = &40 E wall load = 1, 854 ��`"'_-` <br /> Area of W wall = 451 W wall load = 2, 302 '�.v N�� <br /> Total wall area = 1,335 Total wall trans. = 4, 877 O o�,,�' <br /> Area of roof = �1, 088 Roof load = 1, 938 g� <br /> Safety factor = 0% Safety load = Q <br /> Supply fan hp = 0.30 Fan heat gain (DT) = 929 Q ¢ <br /> Ventilation cfm = 152 Vent sensible load = 3, 183 � � � <br /> Vent latent load = 6, 169 � z Q <br /> People latent load = 2,478 Q � � <br /> Total cfm-std air= 2,117 Total latent load = 8, 647 z w z <br /> oz ° <br /> Room sensible = 44,238 Room latent = 2,478 p z � <br /> Plenum return exhaust credit = 0 � Q � <br /> --> GRAND TOTAL LQAD = 56, 998 Btu/hr or 4.75 tons <-- m � Q <br /> Load run f or # 6. AUG at 5 P.M. z c� <br /> a° o ° <br /> Area (sq ft} = 1, 088 Sq ft/ton = 229 p O o <br /> Total cfm-std air= 2, 117 Cfm/sq ft = l.95 -� U -� <br /> HEATING LOAD <br /> ------------------------------------------------------------------------ <br /> Ventilation load = 6, 199 Roof heating load = 2, 013 <br /> Glass heat load = . 11, 916 Wall heating load = 6, 915 <br />
The URL can be used to link to this page
Your browser does not support the video tag.