<br /> APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
<br /> Table Deck Application Type Description Page
<br /> lA Wood New, Reroof(Tear-Of�, Recover C Mechanically Attached Insulation, Bonded Roof Cover 3
<br /> SB Wood New Construction F Non-Insulated, Bonded Roof Cover 3
<br /> ZA Steel or Conc. New, Reroof(Tear-Of�, Recover C Mechanically Attached Insulation, Bonded Roof Cover 4-6
<br /> 2B-1 Steel or Conc. New, Reroof(Tear-Off), Recover D Insulated, Mechanically Attached Roof Cover(Stress Plates) 7
<br /> 2B-2 Steel or Conc. New, Reroof(Tear-Of�, Recover D Insulated, Mechanically Attached Roof Cover(Battens) 8
<br /> 3A Concrete New, Reroof(Tear-Of� A-1 Bonded Insulation, Bonded Roof Cover 9-10
<br /> 3B Concrete New, Reroof(Tear-Of� F Non-Insulated, Bonded Roof Cover 10
<br /> 4A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 11-12
<br /> The following notes apply to the systems outlined herein:
<br /> 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through
<br /> proper codified and/or FBC Approval documentation.
<br /> 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following
<br /> eng .
<br /> L Wood Deck: Mule-Hide HDP Fastener with Mule-Hide 3 in. Insulation Plate, OMG #12 or#14 Roofgrip with Flat Bottom Plate, OMG #12 Standard or#14
<br /> HD with OMG Standard metal plate, Dekfast #12 or #14 with Hex Plate, Tru-Fast DP or HD with MP-3 Plates. Minimum 3/a-inch plywood
<br /> penetration, or 1-inch wood plank embedment
<br /> ➢ Steel Deck: Mule-Hide HDP Fastener with Mule-Hide 3 in. Insulation Plate, OMG #12 or#14 Roofgrip with Flat Bottom Plate, OMG #12 Standard or#14
<br /> HD with OMG Standard metal plate, Dekfast #12 or #14 with Hex Plate, Tru-Fast DP or HD with MP-3 Plates. Minimum 3/a-inch steel
<br /> penetration, engage the top flute of the steel deck.
<br /> � Concrete Deck: Mule-Hide HDP Fastener or Mule-Hide CF with Mule-Hide 3 in. Insulation Plate,OMG#14 Roofgrip with Flat Bottom Plate,OMG#14 HD or CD-
<br /> 10 with OMG Standard metal plate, Dekfast #14 or Dekspike with Hex Plate, Tru-Fast HD or CF with MP-3 Plates. Minimum 1-inch
<br /> embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions.
<br /> 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck
<br /> Prime, DensDeck DuraGuard, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board that meets the QA requirements of F.A.C. Rule
<br /> 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or Z603.6, when installed with the roof cover.
<br /> 4. Minimum 200 psi, minimum Z-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically
<br /> attached membrane), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural
<br /> deck shall be of equal or greater configuration to the steel and concrete deck listings.
<br /> 5. Preliminary insulation attachment for System Type D = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board.
<br />�I
<br /> Exterior Research and Design,LLC.d/b/a Trinity � ERD Evaluation Report M31240.11.09-R3 for FL10703-R4
<br /> Certificate of Authorization#9503 Revision 3: 09/20/2013
<br /> Prepared by: Robert Nfeminen,PE-59166 Appendix 1, Page 1 of 12