My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15533
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15533
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2015 7:48:03 AM
Creation date
8/19/2015 7:48:01 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
14-15533
Building Department - Name
RIOPELLE,ROANALD & MARIAN
Address
5923 14TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, FORMS <br /> �'Z� �e�"0� <br /> TASLE 402A �xC�Y/ <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U-Factor<0.65 / <br /> Windows(see Note 2): SHGC=0.30 U-Faclor= •1CJ <br /> %oICFA<=20% ✓ SHGC= - 3� <br /> S li hls U-Factor<0.75 %o(CFA= G�,JC <br /> � Doors:Exterior door U-Factor U-Feclor<0.65 1/ U-Factor= ��O Jr <br /> Floors: Slab-on-grade Norequirement � R-Value= (�O 2EQ• <br /> Over unconditioned s aces sea Note 3 R-13 <br /> Walis—Ext.and Adj.(see Note 3): <br /> Frame R-13 ./ R-Value= �q <br /> Mass (see Nota 3) �� <br /> Inlerior of wall: R-7.8 R-Value= <br /> Exterior oF wall: R-6 R-Vaiue= <br /> Ceilings�see Notes 3&4) R=30 �a� Qt,�� R-Value= �( Attached7 <br /> Reflectance 025 Rellectance= Yes/No <br /> Air distribu[ion syslem(see Note 4) - / <br /> Ductwork&air hendling unit: y Localion: j/I'P�/�Qit(/� Test re ort <br /> Unconditioned space Not allowed /� C��� Attached? <br /> Condltioned space ''� Yes/No <br /> Duct R-value R-value 2 6 R-Value= (p <br /> Air leakage�n Qn 5 0.03� ��_ <br /> Air condi6onin s stems see Note 5 SEER=13.0 SEER= <br /> Heating system •��� <br /> Heat pump(see Note 5) Cooling: SEER=13.0 x SEER= .,,( <br /> Heating: HSPF=7.7 HSPF= r j <br /> � <br /> Gas furnace AFUE 78% AFUE_ <br /> Oil fumace AFUE 78% AFUE_ <br /> Electric resistance:Not allowed(see Note 5) <br /> Water heating system(storage type) �� <br /> Electrlc(see Note 6): 40 gal:EF=0.92 Gallons= � <br /> 50 gal:EF=0.90 EF= <br /> Gas fired(see Note�: 40 gal:EF=0.59 Gallons= <br /> Other(describe): 50 gal:EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet orexceed each otthe applicable performance criteria in order to comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must complywith both the maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria <br /> and have a maximum total window area equai to or less than 20%of the conditioned Floor area(CFA);otherwise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instruciions.For mass walls,the°interiorof walf'requirement must be <br /> mel except it at least 50%of the R-6 insulation required for the°exterior of wall"is installed exterior of,or integral to,the wall. <br /> (4)Ducts&AHU installed substantially leak free per Section 403.22.1.Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.72. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other lypes oi equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(O.OD132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 4028 MANDATORY REQUIREMENTS <br />� COMPONENTS SEC710N RE�UIREMENTS CHECK <br /> To be caulked,gasketed,weatherslripped or olhervrise sealed.Recessed lighting IGrated as meeling ASTM E <br /> Air leakage 402.4 283.Windows and doors=0.30 cfm/sq.R.Testing or visual inspection required.Flreplaces:gasketed doors 8 ✓ <br />' outdoor combustion air. <br />� Ceilings/knee walls 4052.1 R-19 space permitting. � <br /> Programmable lhermostat 403.1.1 VJhere forced-air furnace is primary syslem,programmahle lhermostat is required. N�/Q <br /> Air dis�ri6u6on system 4032 Ducts in attics o�on roofs Insu`�ated lo R-8;other ducts R•6.Ducts tesled to Q,=0.03 by e Class 7 BERS rater. <br /> Heal trap required for vert(cal pipe risers.Comply with efficiencies in Table 403.4.32.Provide swilch or clearly ��� <br /> Waler heaters 403.4 marked circuit breaker(electric)or shuloff(gas).Circulating system pipes insuleted to=R•2+accessible manual <br /> OFF switch. <br /> Spas and heated pools must have vapor-retardant covers or a Iiquid cover or other means prove�to reduce heat <br /> Srvimming pool&spas 403.9 lass except i}70%of hea[from site-recovered energy.Offhimer switch required.Gas healers minimum thertnal �f/� <br /> efficien =78% 82%aher 4/16/13.Heat um ool heaters minimum COP=4.0. l <br /> Sizing calculation performed&altached.Minimum efficiencies per Tables 5032.3.Equipment etficiency verification ,�/`,A <br /> Cooling/heating equipmenl 403.6 required.Special occasion cooling or heating capecity requires separate system or varia6le capacity system. �l//�J <br /> Eleclric heat>10kW must be divided into two or more sta es. <br /> Lighting equipment 404.1 At leasl 50%01 permanently installed Iigh[ing fixtures shall be high-efficacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION C.5 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.