My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15548
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15548
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2015 7:59:47 AM
Creation date
8/19/2015 7:59:38 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
14-15548
Building Department - Name
KENNEDY,ADAM & ABIGAIL
Address
39027 PARK DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' ') <br /> ��� <br /> �`�..� TRINiI'Y I ERD <br /> 5.5 Allowable substrates are noted below: <br /> 5.5.1 Direct-Bond to Deck: <br /> Lastobond Shield, Lastobond Pro HT-IV Lastobond Shield HT or Lastobond Pro HT-S applied <br /> to: <br /> ➢ Plywood; <br /> ➢ ASTM D41 primed plywood; <br /> ➢ OSB; <br /> ➢ ASTM D41 primed OSB; <br /> ➢ Southern Yellow Pine; <br /> ➢ ASTM D41 primed Southern Yellow ine; <br /> ➢ ASTM D41 primed structural concre e. <br /> Lastobond TU HT, Lastobond, Lastobon 195, Lastobond ECO, Resisto L61236, Grip-Rite Eave <br /> &Valley Protector, Resisto LB1244 or L stobond Smooth Seal HT applied to: <br /> Y Plywood; <br /> ➢ ASTM D41 primed plywood; <br /> ➢ OSB; <br /> ➢ ASTM D41 primed OSB; <br /> ➢ ASTM D41 primed structural concre e. <br /> Colphene FR GR applied to: <br /> ➢ Plywood; <br /> ➢ ASTM D41 primed plywood; <br /> ➢ ASTM D41 primed structural concre e. <br /> Note: <br /> ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema <br /> recommends priming with Elastoc l Stick or Elastocol 600c if the final roof cove� is not <br /> slated for installation within 24 hou s. <br /> ➢ Soprema requires tongue-and-groo e board decking be covered with plywood or OSB prior <br /> to installation of the self-adhering nderlayment. <br /> 5.5.2 Bond-to-Insulation: <br /> Lastobond TU HT, Lastobond Shield, La tobond Pro HT-N, Lastobond Shield HT, Lastobond Pro <br /> HT-S or Colphene FR GR applied to: <br /> ➢ DensDeck DuraGuard; <br /> ➢ DensDeck Prime; <br /> ➢ SECUROCK Gypsum-Fiber Roof Board. <br /> For installation under mechanically attached prepared roof coverings, insulation shall be <br /> attached per minimum requirements f the prepared roof covering manufacturer's Product <br /> Approval. For installations under f am-on tile systems, insulation attachment shall be <br /> designed by a qualified design p fessional and installed based on testing of the <br /> insulation/underlayment system in a cordance with FM 4474, Appendix D or TAS 114, <br /> Appendix J. <br /> 5.5.3 Bond to Mechanicall Attached Base La er: <br /> Lastobond Shield, Lastobond Pro HT-N Lastobond Shield HT, Lastobond Pro HT-S or Coiphene <br /> FR GR applied to: <br /> ➢ ASTM D226, Type I or II felt; <br /> ➢ Sopra-G; <br /> ➢ Modified Sopra-G. <br /> For installations under mechanically ttached prepared roof coverings, base layer shall be <br /> attached per minimum codified requir ments. For installations under foam-on tile systems, <br /> base layer shall be attached per minim m requirements of FRSA/TRI 07320/8-05 or RAS 120. <br /> Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R5 <br /> Certifcate ofAuthoriaation#9503 FL2569-R7 <br /> Revision 5: 04/30/2014 <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.