My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15549
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15549
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2015 8:00:25 AM
Creation date
8/19/2015 8:00:23 AM
Metadata
Fields
Template:
Building Department
Company Name
MAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
14-15549
Building Department - Name
MAJESTIC OAKS LLC
Address
3647 BLACK DIAMOND DR LOT 239
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+ - . r�u.... .v...vr.. <br /> Slte Preparation <br /> POCKET PENETROMETER TEST <br /> � ,�, Debris and organic material removed X <br /> - The pocket penetrometer tests are rounded down to 1500 psf Water drainage:Natural X Swale Pad Other <br /> or check here to declare 1000 Ib.soil without testing. � <br /> Fastenins�multi wlde units <br /> X 1700 X 1600 X 1600 <br /> Floor: Type Fastener: Length: Spacing: <br /> Walls: Type Fastener: Length: Spacing: <br /> POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Length: Spacing: <br /> For used homes a min.30 gauge,8"wide,galvanized metal strip <br /> 1. Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv. <br /> roofing nails at 2"on center on both sides of the centerline. <br /> 2. Take the reading at the depth of the footer. , • ' <br /> ' G0Sk8t(weatherorootlna reaulreinentl <br /> 3. Using 500 Ib. increments,take the lowest� - - � ; � ' <br /> reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used <br /> homes and that condensation;mold, meldew and buckled marriage walls are <br /> a result of a poorly installed or no gasket being installed. I understand a strip <br /> X 1600 X 1500 X 1700 of tape will not serve as a gasket. <br /> Installer's initials <br /> TORQUE PROBE TEST <br /> Type qasket Installed: <br /> The results of the torque probe test is 277 inch pounds or check Pg. Between Floors Yes <br /> here if you are declaring 5'anchors without testing . A test Between Walls Yes <br /> showing 275 inch pounds or less will require 5 foot anchors. ,_ . Bottom of ridgebeam Yes <br /> Note: A state approved lateral arm system is being used and 4 ft. <br /> anchors are allowed at tfie sidewall locations. I understand 5 ft . - °-�°Weatherproot�ng <br /> anchors are required at all centerline�tie points where the torque test _ � <br /> reading is 275 or less and where the mobile�home manufacturer may The bottomboard will be repaired and/or taped. Yes X . Pg. <br /> requires anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications. Yes_) <br /> '. Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes�g <br /> ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER � Miscellaneous <br /> Installer Name Lionel Easler Skirting to be installed. Yes No <br /> Dryer vent installed outside of skirting. Yes N/A X � <br /> Date Tested 7/30/2014 Range downflow vent installed outside of skirting. Yes N/A�_ <br /> _ - -� Drain lines supported at 4 foot intervals. Yes X <br /> � _ � Electrical crossovers protected. Yes NA <br /> Other: <br /> Electrlcal , <br /> Connect electrical conductors between multi-wide.units, but not to the.main power ' - � �� - ' <br /> source. This includes the bonding wire�between.mult-wide units. 'Pg. NA - <br /> Installer verifies all information glven with this permlt worksheet <br /> _ � um na is accurate and true based on the <br /> ,. --, �- � �•. manufacturer's Installation instructions and or Rule 15C-1 &2 <br /> Connect all sewer drains to an existing sewer tap or septic tank. Pg, <br /> Connect all potable water supply piping to an existing water meter,water tap, or other Installer Signatur�� C��'� Date i/1/2�14 <br /> independent water supply systems. Pg. <br />
The URL can be used to link to this page