FORM 405-10 <br /> Florida Code Com liance Checklist <br /> • Fiorida Department of Business and Professional Regulations <br /> Residential Whole Buildin Pertormance Method <br /> ADDRESS: PERMIT#: <br /> , FL, <br /> MANDATORY REQUIREMEIVTS SUMMARY-See individua code sections for full details. <br /> COMPONEN7 SEC7iON $UMMARY OF EQUIREMENT(S) CHECK <br /> Air leakage 402.4 To be caulked, gasketed weatherstripped or otherwise sealed. <br /> Recessed lighting IC-rat cf as meeting ASTM E 283. Windows and <br /> doors=0,30 cfm/sq.ft.T sting or visual inspecti�n required. Fireplaces: <br /> gasketed doors&outcio r combustion air. Must complete envelope <br /> leakage report or visuall verify Table 402.4.2. <br /> Thermostat& 403.9 At least one thermostat hall be provided for each separate heating and <br /> controls cooling system.Where f rced-air furnace is primary system, <br /> programmable thermost t is required. Heat pumps with supplemental <br /> electric heat must preve t supplemental heat when compressor can <br /> meet the load. <br /> Ducts 403.2.2 All ducfs, air handlers, fil er boxes and building cavities which form the <br /> primary air containment assageways for air distribution systems shall <br /> be considered ducts or enum chambers,shall be constructed and <br /> sealed in accordance wi h Section 503.2.7.2 of this code. <br /> 403.3.3 Building framing cavifies shall not be used as supply ducts. <br /> Water heaters 403.4 Heat trap required for ve ical pipe risers. Comply with efficiencies in <br /> Table 403.4.3.2. Pravide switch or clearly marked circuit breaker <br /> (e(ectric)or shutoff(gas) Circulating system pipes insufated to= R-2 <br /> +accessibfe manual OF switch. <br /> Mechanical 403.5 Homes designed to ope ate at positive pressure or with mechanical <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. <br /> No make-up air from atti s, crawfspaces, garages or outdoors adjacent <br /> to pools or spas. <br /> Swimming Pools 403.9 Pool pumps and pool pu p motors with a total horsepower(HP) of=1 <br /> &Spas MP shafl have the capa lity of operating at fwo or more speeds. Spas <br /> and heated paols must ave vapor-retardant covers or a liquid cover or <br /> other means proven t�r duce heat loss except if 70% of heat from <br /> site-recovered energy. ffltimer switch required. Gas heaters minimum <br /> thermal efficiency=78% 82%after 4/16I13), Fieat pump pool heaters <br /> minirnum COP=4.0. <br /> Coolinglheafing 403.6 Sizing calculation perFor ed&attached. Minimum efficiencies per <br /> Tables 503.2.3_ Equipm nt efficlency verification required. Special <br /> equipment occasion cooling or hea ing capacity requires separate system or <br /> variable capacity syste . Electric heat�10kW must be divided into two <br /> or more stages. <br /> Ceilings/knee wal[s 405.2.1 R-19 space permltting <br /> 3l29/2012 3:28 PM , EnergyGauge�USA-FlaRes2010 ection 405.4.1 Compliant Software Page 5 of 5 <br />