Laserfiche WebLink
FO'RMS <br /> TABLE 402A <br /> BUILDING COMPONENT PERFORMANCE CRITEAIA' INSTALLED VALUES: <br /> U-Factor<0.65 ✓ <br /> wndows(see Nole 2): SHGC=0.30 ✓ U-Faclo�_ <br /> %o(CFA<=20% ✓ SHGC= <br /> S liohls U-Faclor<0.75 %of CFA= • <br /> Doors:Ezterior door U-Factor U-Factor<0.65 ✓ U-Factor= <br /> Floors: Slab-on-grade No requirement R-Value= <br /> Over unwnditioned s aces see Nole 3 R-13 �/ <br /> Walls—EzL and Adj.(sea Nota 3): � <br /> Frame R-13 ✓ R-Value= <br /> Mass (see Nole 3) <br /> �Interior ol wall: R-7.8 R-Value= <br /> Exlerior of wall: R-6 R-Value= <br /> Ceilings(see Notes 3&4) R=30 � R-Value= Tesl repoh <br /> Reflectance 025 Relleclance= Atteched7 <br /> Yes/No <br /> Afr distribution syslem(see Note 4) <br /> Ductwork&air handling unit: Location: <br /> Unconditioned space Not allowed Test repoA <br /> Conditionad space Attached? <br /> Duct R-value R-value 2 6 ✓ � Yes/No <br /> R-Value= <br /> Air leakage�n On 5 0.03 Q�_ <br /> Alr condilionin s stems see Note 5 SEER=13.0 SEER= <br /> Heating syslem <br /> Heat pump(see Note 5) Cooling: SEER=13.0 ✓ SEER= <br /> Heating: ' HSPF=7.7 ✓ HSPF= <br /> Gas fumace AFUE 76% AFUE_ <br /> �Oil fumace AFUE 7 / AFUE_ - , <br /> Electric resislance:Nol ellowed(see Note 5) - <br /> Water healing system(storage type) <br /> Electric(see Nole 6): 40 gal:EF=0 2 Gallons= <br /> 50 gal:EF .90 EF= <br /> Gas fired(see Note 7): _ 40 gal: =0.59 Gallons= <br /> Other(describe): 50 g ,EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet or exceed each of ihe appiicable performance criteria in order to comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must complywith both the maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%oi the conditioned floor area(CFA);otherwise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interiorof wall"requirement must be <br /> met except if at least 50%o(the R-6 insulation required for the"exterior ot wall"is installed exterior of,or integral to,the wall. <br /> (4)Ducts&AHU installed substantially leak free per Section 4032.2.1 Test by Class 1 BERS rater required. <br /> Excepfion:Ducts installed onto an existing air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.72. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does nol apply to addilions,renovations and new heating sy'stems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 402B MAN�ATORY RE�UIREMENTS <br /> COMPONENTS SECTION REOUIREMENTS CHECK <br /> To be caulked,gasketed,wealherstripped or otherwise sealed.Recessed lighting IC-rated as meeting ASTM E <br /> Air leakage 402.4 283.Windows and doors=0.30 cfm/sq.fl.Tesling or visual inspeclion required.Fraplaces:gasketed doors& � <br /> outdoor combusfion air. <br /> Ceilings/knee wails 405.2.1 R-19 space permitting. � <br /> Programmable thermostal 403.1 1 Where forced-air furnace is primary system,programma6le thermoslal is required. <br /> Air distribution system. 4032 Ducts in atlics or on roo(s insulated lo R-8;other duc[s R-6.Ducts tesled to O,=0.03 by a Class 1 BERS rater. �/ <br /> Heat lrap required for veRical pipe risers.Comply with efficiencies in Table 403.4.32.Provide switch or Gearly' <br /> Water heaters 403.4 marked circuil breaker(electric)or shutoff (gas).Circulaling system pipes insulaled to=R-2+accessible manual <br /> OFF switch. <br /> Spas and healed pools musl have vapor-retardant covers or a liquid cover or other means proven to reduce heal <br /> Swimming pool&spas 403.9 loss except it 70%of heat from site-recovered energy.Oft/timer switch required.Gas healers minimum Ihermal <br /> effcienc =78q 82%afler 4/16/13.Heal um ool heaters minimum COP=4.0. <br /> Sizing calculation peAormed&atlached.Minimum efficiancies per Tables 5032.3.Equipment efficiency verification <br /> CoolingRieating equipmenl 403.6 required.�Special occasion cooling or heating capacity requires separale system or variable capacily syslem. ✓ <br /> Eleclric heal>10kW must be divided into two or more sla es. <br /> Lighting equipment 404.1 At least 50%of pertnanentiy installed lighting fiutures shall be high-eKcacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION C.5 <br />