Laserfiche WebLink
� ' Rhvac=Residential&Light Commercial HVAC Loads Elite Sofiware Development,Inc. <br /> HVAC Designs � Walnut Grove TH 1456 S <br /> Tam a FL 33615 Pa e 6 <br /> Total Buildin Summa Loads <br /> Component Area Sen Lat Sen Total <br /> Descri tion Quan Loss Gain Gain Gain <br /> OP LOW E MIN:Glazing-NFRC CODE MIN Operable 2 116.3 1,861 0 2,960 2,960 <br /> Pane Low E,ground reflectance=0.23,outdoor <br /> insect screen with 50%coverage,light color blinds <br />� at 45°with 100%coverage,u-value 0.5,SHGC 0.5 <br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278 <br /> Pane Low E,ground reflectance=0.23,light color <br /> blinds at 45°with 100°/a coverage,u-value 0.5, <br /> SHGC 0.5 <br /> 11N:Door-Metal-Polystyrene Core 40 434 0 343 343 <br /> 12B-Osw:Part-Frame,R-11 insulation in 2 x 4 stud 154.6 450 0 300 300 <br /> cavity,no board insulation,siding finish,wood <br /> studs <br /> 13A•4ocs:Wall-Block,board insulation only,R-4 board 669 3,062 0 1,748 1,748 <br /> insulation,open core,siding finish <br /> 13A-4ocs:Part-Block,board insulation only,R-4 board 124 532 0 355 355 <br /> insulation,open core,siding finish <br /> 16B-30-ad:RooflCeiling-Under Attic with Insulation on 1455.9 1,491 0 2,469 2,469 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings),vented attic,no radiant barrier,R-30 <br /> insulation,dark asphalt <br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 142 5,362 0 0 0 <br /> insulation below floor,any floor cover,passive, <br /> hea d or li ht wet soil <br /> Subtotals for structure: 13,512 0 8,453 8,453 <br /> People: 4 920 1,200 2,120 <br /> Equipment: 640 2,040 2,680 <br /> Lighting: 0 0 0 <br /> Ductwork: 2,246 310 2,047 2,357 <br /> Infiltration:Winter CFM:136,Summer CFM:70 4,779 2,047 1,382 3,419 <br /> Ventilation:Winter CFM:0,Summer CFM:0 0 0 0 0 <br /> AED Excursion: 0 0 652 652 <br /> Total Building Load Totals: 20,537 3,917 15,773 19,690 <br /> Check Fi ures <br /> Total Building Supply CFM: 850 CFM Per Square ft.: 0.584 <br /> Square ft.of Room Area: 1,456 Square ft.Per Ton: 831 <br /> Volume(ft')of Cond.Space: 11,647 <br /> Buildin Loads <br /> Total Heating Required Including Ventilation Air: 20,537 Btuh 2 537 MBH <br /> Total Sensible Gain: 15,773 Btuh 80 % <br /> Total Latent Gain: 3,917 Btuh 20 % <br /> Total Cooling Required Including Ventilation Air: 19,690 Btuh .75 Tons(Based On 75%Sensible Capacity) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and A CA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according t the manufacturer's performance data at your design conditions. <br /> Thursday,May 08,2014,1:03 PM <br />