Laserfiche WebLink
WA LS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 0 <br /> _ 1 W=>E Garage Frame-Wood HVAC 1 1 i 3 0 8 0 24.0 ft2 0 0.23 0.01 0 <br /> _ 2 N=>S Garage Frame-Wood HVAC 1 11 2.83 0 8 0 22.6 ftz 0 0.23 0.01 0 <br /> _ 3 W=>E Garage Frame-Wood HVAC 1 i 1 6.33 0 8 0 50.6 ft2 0 0.23 0.01 0 <br /> _ 4 N=>S Exterior Concrete Block-lnt Insu/ HVAC 1 4 5.33 0 8 0 42.6 ftz 0 0 0.35 0 <br /> _ 5 N=>S Exterior Concrete Block-Int Insul HVAC 1 4 12.17 0 8 0 97.4 itz 0 0 0.35 0 <br /> _ 6 E=>W Garaqe Concrete Block-Int Insu/ HVAC 1 4 15.5 0 8 0 124.0 RZ 0 0 0.01 0 <br /> _ 7 W=>E Exterior Concrete Block-Int Insu/ HVAC 1 4 13.17 0 8 0 105.4 ftz 0 0 0.35 0 <br />'� _ 8 N=>S Garage Frame-Wood HVAC 1 11 9.67 0 8 0 77.4 it2 0 0.23 0.01 0 <br /> _ 9 W=>E Exterior Concrete Block-lnt Insu/ HVAC 1 4 9.67 0 8 0 77.4 ftz 0 0 0.35 0 <br /> _10 S=>N Exterior Concrete Block-Int Insu/ HVAC 1 4 16.33 0 8 0 130.6 ft2 0 0 0.35 0 <br /> _i 1 W=>E Exteiior Concrete Block-Int Insul HVAC 1 4 16 0 8 0 128.0 ftz 0 0 0.35 0 <br /> _12 S=>N Exterior Concrete Block-Int lnsul HVAC 1 4 13.83 0 8 0 110:6 Rz 0 0 0.35 0 <br /> _13 W=>E Exterior Concrete Block-lnt Insu/ HVAC 1 4 8.33 0 8 0 66.6 it2 0 0 0.35 0 <br /> _i4 E=>W Exterior Concrete Block-Int/nsu! NVAC 1 4 8.33 0 8 0 66.6 ftz 0 0 0.35 0 <br /> DOO S <br /> # ' Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft ln Ft ln <br /> 1 W=>E Insu/ated HVAC 1 None 0.35 3 0 6.67 0 20.01000 <br /> 2 N=>S Insu/ated HVAC 1 None 0.35 3 0 6.67 0 20.Oi000 <br /> WIND WS <br /> Orientation shown is the entered orientation = chan ed to As Buill rotated i80 de rees. <br /> / Wal! Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor S GC Area Depth Separation Int Shade Screening <br /> i N=>S 5 TIM Low-E Double Yes 0.5 .5 16.2 itz 1 ft 0 in 1 it 0 in Drapes/blinds Exteiior 5 <br /> 2 W=>E 7 TIM Low-E Double Yes 0.5 .5 i6.2 ftz 1 ft 0 in 1/t 0 in Drapes/blinds Exterior 5 <br /> 3 W=>E 9 TIM Low-E Double Yes 0.5 .5 9.8 ftz 1/i 0 in 1/t 0 in Drapes/blinds Exterior 5 <br /> 4 S=>N 10 TIM Low-E Doubfe Yes 0.5 .5 12.8 ft2 9 ft 0 in 0(t 0 in Drapes/blinds Exterior 5 <br /> 5 S=>N 10 TIM Low-E Doub/e Yes 0.5 .5 i2.8 ft2 91t 0 in 0 it 0 in Drapes/blinds Exterior 5 <br /> 6 S=>N 10 TlM Low-E Doub/e Yes 0.5 .5 20.0 ft2 9 ft 0 in 0 ft 0 in Drapes/blinds None <br /> 7 W=>E 11 TlM Low-E Doub/e Yes 0.5 .5 16.2 ft2 1/t 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 8 W=>E 11 TIM Low-E Double Yes 0.5 .5 16.2 it2 1 ft 0 in 1 ft 0 in Drapes/blinds Exierioi 5 <br /> 9 S=>N 12 TIM Low-E Double Yes 0.5 .5 16.2 ftz 1 it 0 in 1 fr 0 in Drapes/blinds Exterior 5 <br /> � GARA E <br /> # Floor Area Ceiling Area Exposed Wa Perimeter Avg. Wall Height Exposed Wall Insu/ation <br /> 1 288 ftz 288 ft2 50 8 ft 0 <br /> 5/8/2074 1:11 PM EnergyGauge6�USA-F/aRes2010 Se tion 405.4.1 Compliant Software Page 3 of 6 <br />