FoRM ao�-�o ' <br /> Florida Code Complia ce Checklist - <br /> Florida Department of Business and rofessional Regulafions <br /> Residential Whole Building Pe ormance Method <br /> ADDRESS: 4408 Court Street PERMlT#.� <br /> Zephyrhills,FL,33542- <br /> , <br /> MANDATORY REQUIREMENTS SUMMAR'Y-See individual co e sections for full details. <br /> COMPONENT SECTION SUMMARYOF REQ lREMENT(S) CHECK y <br /> Airleakage 402.4 To be caulked,gasketed, wea herstripped vrothe�vuise sealed. <br /> Recessedlighfing IGrated as eeting ASTM E 283. �ndows and <br /> doors=0.30 cfm/sq.ft Tesfin or visual rnspection reguired. �/ <br /> Fireplaces:gasketed doors& utdoor combustion air. Must complete , <br /> envelope leakage report or vi ally verify Table 402.4.2. <br /> Themiosfat& 403.9 At/east one thermostat sha!! e provided for each separate heafing <br /> controls and cooling sysfem. Where fo ced-air furnace is•primary sysfem, -✓ <br /> programmable thermostat is guired.Heat�pumps wifh supplemental <br /> elecfric heat must prevent su lementa!heat when compressor can <br /> meet the load. • <br /> , <br /> Ducts 403.2.2 Al!ducts, air handlers, �Iter b xes and building cavities which form the <br /> primary air containment pass�geways for air disfribution systems shal! <br /> be considered ducts or plenu chambers,shal/be constructed and � <br /> sea/ed in accordance with Se tion 503.2.7.2 of this code. <br />�� 403.3.3 8uilding framing cavifi�s sha11 not be used as supply ducts. <br /> Water heaters 403.4 Heat trap required for verfica! ipe risers. Comply wrth efficiencres in <br /> Table 403.4.3.2.Provide swit h or cleariy marked circuif breaker <br /> (elecfric)or shutoff(gas). Ci lating sysfem pipes insu/ated to= � <br /> R-2+accessible�nanual OF switch. <br /> I Mechanrcal 403.5 Homes designed fo operate a positive pressure or with mechanical <br /> ventila6on ventilation systems shall not xceed the minimum ASHRAE 62 leve/. � <br /> • No make-up air from attics, c wlspaces,garages or oufdoors adjacent ,/ <br /> . to pov/s or spas. . � ,. <br /> SwimmingPools 403.9 'Pool pumps and pool pump ofors with a fota/horsepower(HP)of=1 � <br /> &Spas _ HP shall have the capability f operating at two or more speeds. Spas <br /> , ;:� �•� ` � ,�nd�heafed pools must have apor-retardant covers ora liquid cover or� <br /> � • - � other means proven to reduc heatloss except if 70%of heaf from <br /> . sife-recovered energy. Off/ti er swifch required. Gas heaters minimum +?�� <br /> thermal e�ciency=78%(82%after 4/16/13). Heat pump pool heaters , � <br /> � minimum COP=4.0. <br /> Cooling/heating ' 443.6 Sizing calculation pe�formed aftached.Minimum e�crencies per � <br /> 'Tables 503.2.3.Equipment e �ciency verrfication reguired. Specia! <br /> equipment oc�asron cooling or heafing c pacity requires separ.ate system or ; � <br /> variable capaciry system. Ele trrc heat>10kW must be divided into two � <br /> ormore stages. " <br /> Ceilings/kneewa!!s 405.2.1 R-19 space permitting. , , <br /> 5�8/2014 i 1:07 AM FnergyGauge�USA-FlaRes2010 Sectlo 405.4.1 Complienf SoNwa�e Page 5 of 5 <br /> . ` <br />