Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> HVAC Designs : Walnut Grove TH 1505 S
<br /> Tam a FL 33615 Pa e 7
<br /> S stem 1 Room Load Summa
<br /> Htg Min Run Run Clg Clg Min Act
<br /> Room A�a Sens Htg Duct Duct Sens Lat Cig Sys
<br /> No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
<br /> —Zone 1—
<br /> 2 Foyer 71 2,518 57 4 - 1,108 263 56 57
<br /> 3 Bed 2 180 3,953 90 6 - 2,414 361 122 124
<br /> 4 Bath 2 60 1,071 24 4 • 498 187 25 26
<br /> 5 Kitchen 283 325 7 6 - 2,349 500 119 121
<br /> 6 Bed 3 171 2,030 46 5 - 1,599 182 81 82
<br /> 7 Great!Dining 335 5,344 122 7,7 - 6,035 1,384 305 310
<br /> 8 M Bed 248 4,472 102 6 - 2,129 425 108 109
<br /> 9 M Wic 39 45 1 4 - 84 0 4 4
<br /> 10 M Bath 118 136 3 4 • 351 80 18 18
<br /> Duct Latent 303
<br /> S stem 1 total 1 505 19 895 452 16 566 3,685 837 850
<br /> System 1 Main TrunK Size: 12x14 in.
<br /> Velocity: 729 ft.lmin
<br /> Loss per 100 ft.: 0.086 in.wg
<br /> Duct size resuits above are from Manual D Ductsize.
<br /> Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize
<br /> report for duct velocities and other data.
<br /> Coolin S stem Summa
<br /> Cooling SensiblelLatent Sensible Latent Total
<br /> Tons S lit Btuh Btuh Btuh `
<br /> Recommended 1.84 75%125% 16,566 5,522 22,088
<br /> ACtual: 2.08 75%!25% 18,750 6,250 25,000
<br /> E ui ment Data
<br /> f, Heatina Svstem Coolina Svstem
<br /> Type: Air Source Heat Pump Air Source Heat Pump
<br /> Model: 4A6H3024C1 4A6H3024C1
<br /> Indoor Model: GAF2AOA24S21+TDR
<br /> Brand: HERITAGE 13 HERITAGE 13
<br /> Description: Air Source Heat Pump Air Source Heat Pump
<br /> Efficiency: 8.2 HSPF 13.75 SEER
<br /> Comment: 0
<br /> Sound: 0 0
<br /> Capacity: 23,600 Btuh 25,000 Btuh
<br /> I, Sensible Capacity: nla 18,750 Btuh
<br /> Latent Capacity: n!a 6,250 Btuh
<br /> AHRI Reference No.: nla 4941302
<br /> This system's equipment was selected in accordance with ACCA Manual S
<br />' Manual S equipment sizing data: SODB:93F,SOWB:77F,WODB:40F,SI B:75F,SIRH:55%,WIDB:72F,Sen.gain:16,566�Btuh,Lat.gain:3,685
<br /> Btuh,Sen,loss:19,895 Btuh,Entering cig.coil DB;75F,Entering cig.coil B;63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg,coil TD:40F,
<br /> Req.clg.airflow:837 CFM,Req.htg,airtlow:452 CFM
<br /> ,
<br /> .
<br /> Thursday,May 08,2014,1:18 PM
<br />
|