Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> HVAC Designs : Walnut Grove TH 1505 S <br /> Tam a FL 33615 Pa e 7 <br /> S stem 1 Room Load Summa <br /> Htg Min Run Run Clg Clg Min Act <br /> Room A�a Sens Htg Duct Duct Sens Lat Cig Sys <br /> No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM <br /> —Zone 1— <br /> 2 Foyer 71 2,518 57 4 - 1,108 263 56 57 <br /> 3 Bed 2 180 3,953 90 6 - 2,414 361 122 124 <br /> 4 Bath 2 60 1,071 24 4 • 498 187 25 26 <br /> 5 Kitchen 283 325 7 6 - 2,349 500 119 121 <br /> 6 Bed 3 171 2,030 46 5 - 1,599 182 81 82 <br /> 7 Great!Dining 335 5,344 122 7,7 - 6,035 1,384 305 310 <br /> 8 M Bed 248 4,472 102 6 - 2,129 425 108 109 <br /> 9 M Wic 39 45 1 4 - 84 0 4 4 <br /> 10 M Bath 118 136 3 4 • 351 80 18 18 <br /> Duct Latent 303 <br /> S stem 1 total 1 505 19 895 452 16 566 3,685 837 850 <br /> System 1 Main TrunK Size: 12x14 in. <br /> Velocity: 729 ft.lmin <br /> Loss per 100 ft.: 0.086 in.wg <br /> Duct size resuits above are from Manual D Ductsize. <br /> Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize <br /> report for duct velocities and other data. <br /> Coolin S stem Summa <br /> Cooling SensiblelLatent Sensible Latent Total <br /> Tons S lit Btuh Btuh Btuh ` <br /> Recommended 1.84 75%125% 16,566 5,522 22,088 <br /> ACtual: 2.08 75%!25% 18,750 6,250 25,000 <br /> E ui ment Data <br /> f, Heatina Svstem Coolina Svstem <br /> Type: Air Source Heat Pump Air Source Heat Pump <br /> Model: 4A6H3024C1 4A6H3024C1 <br /> Indoor Model: GAF2AOA24S21+TDR <br /> Brand: HERITAGE 13 HERITAGE 13 <br /> Description: Air Source Heat Pump Air Source Heat Pump <br /> Efficiency: 8.2 HSPF 13.75 SEER <br /> Comment: 0 <br /> Sound: 0 0 <br /> Capacity: 23,600 Btuh 25,000 Btuh <br /> I, Sensible Capacity: nla 18,750 Btuh <br /> Latent Capacity: n!a 6,250 Btuh <br /> AHRI Reference No.: nla 4941302 <br /> This system's equipment was selected in accordance with ACCA Manual S <br />' Manual S equipment sizing data: SODB:93F,SOWB:77F,WODB:40F,SI B:75F,SIRH:55%,WIDB:72F,Sen.gain:16,566�Btuh,Lat.gain:3,685 <br /> Btuh,Sen,loss:19,895 Btuh,Entering cig.coil DB;75F,Entering cig.coil B;63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg,coil TD:40F, <br /> Req.clg.airflow:837 CFM,Req.htg,airtlow:452 CFM <br /> , <br /> . <br /> Thursday,May 08,2014,1:18 PM <br />