14-15682
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15682
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2015 11:00:26 AM
Creation date
8/27/2015 10:58:25 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR RIDGE
Building Department - Doc Type
Permit
Permit #
14-15682
Building Department - Name
MCMAHON MA A & BLUMENSCHEIN P
Address
6135 ZEPHYR RIDGE DR LOT 14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br /> GENERAL NOTES:SERIES 200 NON-IMPACT SINGLE HUNG WINDOW - <br /> 'I)THIS PRODUCT HAS BEEN DESIGNED&TESTED 70 COMPLY WITH THE RE�UIREMENTS OFTHE FLORIDA ' <br /> 8411LDING CODE,INCLUOINO THE HIOH VELOCITY HURRICANE ZONE(HVHZ). 53-1/B"'TIP-TO-TIP WI�TH <br /> 2)SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 52-1/S'BUCK WIDTH 62-1/8'BUCK WIDTH � <br /> 3)FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY APPROVEO MASONRY NO ANCHORS qg��g• 48-118" <br /> REQUIRED IN VISIBLE LIGHT VISIBLE LIGH7 <br /> ANCHORS.MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE,ASTM C80 CONCRETE FLANGE 8'MAX. <br /> MASONRY UNITS AND CONCRETE WITH MIN.KSI PER ANCHOR TYPE,SEE TABLES fi 8 8,SHEET 4 8 6. FRAME HEAD B 3'MAX. h+— --�D <br /> 4)MA90NRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 5,SHEET 4.ALL WOOD BUCKS LESS THAN A <br /> 1-1/2'THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.IX WOOD BUCK9 ARE OPTIONAL IF UNR IS INSTALLED 4_ � <br /> DIRECTLY TO SUBSTRATE.WOOD BUCK9 DEPICTE�AS 2X ARE 1-1Y1'THICK OR GREATER.1X AND 2X BUCKS L 35•��2� 4 <br /> 8'MAX.FROM ---'—'--�J`�'� � VISIBLE �_ ._ 361Y1" <br /> (WHEN USEO)SHALL BE DESIONED TO PROPERLY TRANSFER LOADS TO1HE STRUCTURE.WOOD BUCK DESION CENTER OF — / —•—� <br /> AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECOR�. MEETINO / 21" LIGHT � � � VISIBLE <br /> RAIL / MAX.O.C. �B� / LIOHT <br /> 5)i1NCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSINO OR&TUCCO.USE ANCHORS TIP-TO 8"MAX.O.C. <br /> OF SUFFICIENT LENGTH AS SPECIFIED ON TABLE 5$8,SHEET 4 8 6.NARROW JOINT SEALANT IS USED ON ALL TIP <br /> FOUR CORNERS OF THE FRAME.INSTALLATION ANCHORS SHOUID BE SEALED.OVERALL SEALINGIFLASHING _____ _ ��,HEIGHT � t <br /> STftATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE A BUCK <br /> OF THESE INSTRUCTIONS. _ / — � HEIGHT / � 77" <br /> 8'MAX.FROM � J BUCK <br /> 6)SHIMS ARE RE�UIRED AT EACH ANCHOR LOCATION WHERE THE PROOUCT IS NOT FLUSH TO THE CEN7ER OF HEIGHT <br /> SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS.WOO�BUCKS,BY OTHERS,MUST BE MEETINO <br /> SUFFICIENTIY ANCHORED TO RESIST LOAOS IMPOSED ON THEM BYTHE WINDOW. RAIL / y3• � <br /> � MAX.O.C. I <br /> 7)DESIGN PRESSURES: 1 ' <br /> A.NEGATIVE�ESIGN LOADS BASED ON STRUCTURAL TEST PRESSURE,FRAME ANALYSIS AND GIASS PER ASTM " <br /> E1300. <br /> B.POSITIVE D[SION LOAD3 BASED ON WATER TEST PRESSURE,3TRUCTURAL 7EST PRESSURE,FRAME B" �—�-�0 NO ANCHOR3 RE�UIRED � —`� <br /> ANALYSIS AND GLASS PER ASTM E1300. MAX. IN FLANOE FRAME SILL 3`MAX. _ . <br /> � 6'MAX.O.C. <br /> 8)THE ANCHORAOE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONOINO TO <br /> THE REQUIRED DESIGN PRESSURE.THE 331l3°/.STRESS INCREASE HAS NOT BEEN USE�IN THE DESION OF TYP. FLANGE FRAME ELEVATION TYP. INTEGRAL FIN FRAME ELEVATION <br /> THIS PRODUCT THE 1.8 COAO DURATION FAC70R WAS USED FOR THE EVALUATION OFANCHORS INTO WOOD. TESTED UNIT� <br /> ANCHORS THAT COME INTO CONTACT WITH OTNER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS ( (TESTED U N IT} <br /> OF THE FLORIDA BUILDINO CODE FOR CORROSION RESISTANCE. <br /> 9)REFERENCES:TEST REPORTS FfL•8479;ELCO ULTRACON NOA;ELCO CRETEFLEX NOA;ANSUAF&PA NDS2005 <br /> FOR WOOD CONSTRUCTION ANO ADM•2006 ALUMINUM DESION MANUAL. <br /> 10)7HE 200 SERIES SINGLE HUNG WINDOW WAS FORMERLY KNOWN A57HE 4060 SERIES(FLANG6 FRAMEj OR OUIUE TO SHEETS: <br /> 400�SERIES(FIN FRAME). OENERAL NOTES.................... 1 <br /> � ELE VATIONS................... ... 1 <br /> ' DESION PRESSURE RATING IMPACT RATINO DESIGN PRESSURES....... 2 8 3 <br /> VARIES, NOT RATED FOR INSTALLATION,FLANOE.............4 <br /> � - SEE SHEETS 2 8 3 IMPACT RESISTANCE INSTALLATION,INTEORAL FlN...6 <br /> WINDOW SHAPES AND SASH CONFIGURATIONS AS SHOWN BELOW OR SIMILAR,MAY BE USED BY INSCRIBING THE ANCHOR�UANTITIES.................6 <br /> i SHAPE IN A'BLOCK AND OBTAININO DESION PRESSURES FOR THAT BLOCK SIZE FROM THE TABLES ON SHEETS 2&3. OLAZING DETAIL3.....................7 <br /> � CORNER AS3EMBLY....._............7 <br /> EXTRUSION PROFILES...............8 <br /> �+— WIDTH —.� {�— WIDTH —►{ PARTS LIST............................ .8 <br /> — -'---- --- --'--'• . <br /> � � ' r �/ PRODl1CTRBVISBD <br /> as mmplyl�w1W 1he Flotl� <br /> � � ��llllllll� OuildfngCode <br /> i Revined 6y: Oole: Revlalon: AcccplenmNo �". 0�3, <br /> ��� a.�l A4/(� i� 8xpirnttpn Dato 1� <br /> HEIOHT HEIGHT � '� • 'P ; JJ <br /> ���'�•'��GENS� F ' 10/10/11 2010 FBC NOTE BY <br /> ��.� '•* i Rovh�d By: Dolr. Ravlelonr �M�om Dade Product CAUII' <br /> / / = -k j Ko.58705 '. <br /> ��f ��� � GENrERAL NOTES&ELEVATION J ROSOWSKI <br /> // � � // ;-�`�.���It �i <br /> ��P . STATC�F ;��_\ <br /> eau��ure PROVIEW/IXiIEL MCH70PPROYI2W/0RIP1 M�IIISTOPE�l1ALLf1E %O�'•,, F��ry�pP.•' G� 1070 TECHNOIACY DRNE Tillc ' Dofr. <br /> ., �cs ..,,..•• ���� N. VENICE. Fl.aavs SINGLE HUNG WINDOW INSI"ALLATION 05/11/11 <br /> ' ��i�IS��NA����� NOKOMISOFL�34274 <br /> ` �������� Se�lee/AlodeC Scala: Shut: Drcwing No. R6v: <br /> ALYNNMILLER,P.E CERT. OF AUTH. �29298 SH�ZOO NTS 1 OF 8 MD-SH2O0-01 A <br /> P.E.p 68706 <br />