Laserfiche WebLink
PERMIT WORKSHEET page 2 of 2 <br /> PERMIT NUMBER <br /> S te Prepara on <br /> Debris and organic material removed � <br /> The pocket penetrometer tests are rounded down to' "��C� psf Water drainage:Natural Slwale Pad ✓ Other <br /> or check here to dedare 10001b. soil without testinp. <br /> X��� X�w X�Jr�I'�j — astening multl wide units <br /> �� Floor. Type Fastener: (�-` S Length:.�c��� Spacing: fo��� <br /> Walls: Type Fastener: �L� Length: �f} Spacinq; " <br /> POCKET PENETROMETER TESTING METHOD Roof: TYPe Fastener: � �t Length: fr,►' Spacfng: <br /> For used homes a n.30 gauqe,8"wide,galvanized metal strip <br /> 1. Test the per�meter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv. <br /> raofing nails at 2"on center on both sides of the cerrterline. <br /> 2. Take the reading at the depth of the footer. <br /> Gesket(weathemroaflno requlnmantl <br /> 3. Using 500 Ib. increments,takethe lowest <br /> reading and round down to thai increment. 1 understand a properly installed qasket is a requiremeM of all new and used <br /> homes and that condensation,mo(d, meldew and buckled marri�.qe walis are <br /> X�0� a resuit af a pooriy instaited or no qasket bein�installed. I understand a strip <br /> X�C� X�,�� of tape will not serve as a gasket. <br /> Installers initials ' <br /> Type gasket � �iA.� �-�'�-'S� Instailed: / <br /> e resu s o e orque pro e <br /> here if you are dedari�q 5'anchors without testing . A test � Between Walls Yes �' <br /> showing 275 inch pounds or less will require 4 foat anchors. Bottom of ridgebeam Yes ✓ <br /> Note: A state approved laterai arm system is being used and 4 ft. <br /> anchors are ailawed at the sidewali locations. I understand 5 ft e erpro ng <br /> anchors are required at ail centerline tle points where the torque test <br /> readinq is 275 or less and where the mobile home manufacturer may The bottomboard will be repaired and/or taped. Yes � . Pg. <br /> requires anchors with 4000 Ib holding capacity. Sidinq on units is installed to manufacturer's specifications. Yes�— <br /> Installer's initiais Fireplace chimney instalied so as not to allow intrusion of rain water. Yes �'� <br /> ALL TESTS MUST BE P�RFORMED BY A LICENSED INSTALLER Miaceilaneous <br /> Instafler Name l�o t C�� I� S�� �`i� J`S^' Skirtinq to be instalied. Yes f No <br /> �� i Dryer vent installed outside of skirtinq. Y� �llA <br /> Date Tested �[__���� 1 (�--� ' � Range downflow vent installed outside of skirti�� Yes �—N!A <br /> Drain lines supported at 4 foot intenrals.�es <br /> Eledrical crossovers proteded. Yes ✓ <br /> Other: <br /> ElectriCSl <br />� Connect electrical conductors between multi-wide uNts,but not to the main power <br /> source. This includes the bondinq wire between mult-wide units. Pg. Insta{le�verifiss ail information given with this permit worksheet <br /> Plumbing is accurate and true based on the <br /> Connect all sewer drains to an exis8ng sewer tap or septic tank. Pg. manufac#urer's installation instructions and or Rule 15C-1 8�2 <br /> Connect all potable water supply piping to an existing water meter,water tap,or other Installer Signatun����r"��'-�°-- Date 1� �( ��' <br /> ia�dependent water supply systems. Pg. • <br />