My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15769
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15769
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2015 2:10:00 PM
Creation date
8/27/2015 2:09:59 PM
Metadata
Fields
Template:
Building Department
Company Name
PARKHILL
Building Department - Doc Type
Permit
Permit #
14-15769
Building Department - Name
HODGES,PERRY & NICKENS INA I
Address
38750 HENRY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ---� <br /> R W R W Building onsultants, Inc.- <br /> BConsulting and Engineering ervices for the Building lndustry. <br /> • � P.O.Box 230 Valrico,FL 7595 Pbone BI3.G59.9197 <br /> Florida Board ofProfessional Enginee s Cenificaie ofAutliorization No.9813 <br /> � / / � // �'II " l � i <br />� �/ ! ' J' � <br /> Product Sub Category Manufacturer - Product Name <br /> Category <br /> Assocfated Materials,Inc. 3100 Structural Mullion � <br /> �ndow Mullions <br /> 3773 State Road <br /> � Cuyahoga Falls,OH 44223 <br /> Phone 330.922.5350 <br /> Scope: This is a Product Evaluation report issued by R W Buildi g Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID# <br /> � 1998)for Associated Materials,Inc.based on Rule Cha ter No.9N-3,Method 2B of the State of Florida Product Approval, . <br /> Department of Commuhity Affairs-Florida Building Com ission. <br /> , RW Building Consultants and Lyndon F.Schmidt,P.E.d not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other ntity involved in the approval process of the product named <br /> - herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 200 &2010 Florida Buitding Code(FBC)excfuding the"High Velocity� <br /> Hurricane Zone". <br /> 2. Wood bucks by others,must be anchored properly to transfer loads to the structure and be reviewed by the building official. <br /> 3. Mullion anchor embedment to base material shall be beyond wall dr ssing or stucco. <br /> 4. When used in areas requiring wind borne debris protection,this pro uct does not require protection with an impact resistant covering <br /> when used in Wind Zones 1,2 and 3 as defined by ASTM E 1996;i Wind Zone 4 as defined by ASTM E 1996,this product must be <br /> protected with an impact resistant covering complying with Section 609.7.2 of the FBC. <br /> 5. Separate product approvals for each glazing product used with hese mullions must be submitted along with this mullion product <br /> approval. � � <br /> 6. Anchoring of each glazing product to the mullion shall be as shown n each iridividual glazing product approval. <br /> 7. Any conditions not covered in this evaluation are subject to separat engineering evaluation. - <br /> 8. Mullion design pressure rating,see load rating table sheets 2 and 3 of drawing FL-12078.1. <br /> 9. The design pressure rating of the assembly shall be the lesser of th load capacity of the mullion as determined using this approval or <br /> the design pressure rating of the individual glazing products used. <br /> 10.Bounding box dimensions for geometric shapes must be equal to o less than the rectangular dimensions shown herein. <br /> 11.See drawing FL-12078.1 for size and design pressure limitations. <br /> Supporting Documenfs: <br /> 1. Drawinq No. Preaared bv - Siqned 8�Sealed bv <br /> No.FL-12078.1 RW Building Consultants,Inc.(CA#9 13) Lyndon F.Schmidt,P.E. <br /> 2. Calculations Preaared bv SiQned 8�5ealed bv <br /> Mullion/Anchoring RW Building Consultants,Inc.(CA#9 13) Lyndon F.Schmidt,P.E. <br /> 3. Quality Assurance <br /> Certificate of Participation issued by Architectural Testing,Inc.,cert fying that Associated Materials,Inc.is /�� <br /> manufacturing products within a quality assurance program that co plies with ISO/IEC 17020 and Guide 53. � / <br /> v <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 9/5/2013 <br /> PF 1309 � � Sheet of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.