� 12/15/2014 Florida Building Code Online
<br /> Date Validated = • 06/09/2014
<br /> ' � Date Pending FBC Approval
<br /> Date Approved 06/16/2014
<br /> I &ummary of Products
<br /> Go to Page � � 'i� Page 1/ 8 Q� �
<br /> f
<br /> _--�__.�.�. �__...�___ �_.._...._�._._ _�_ �.�.��__..�
<br /> FL# ^ j Model,Number or Name E Description
<br /> 15279.1 �001 W3-09 DSIE-1A171: 2050, 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; �
<br /> i 2051, 2053,4050, 4051, 4053, 62, �interior skin 29 ga. min.) Single-Car(up to 9'0"wide)
<br /> i 64, 65, 62G, 62LG, 64G, SDP38, �WINDCODEp W3 Garage Door
<br /> �SFL38, SRP38, 134, 135, 136, 6130, '
<br /> �6131, 6133
<br /> Limits of Use Certification Agency Certificate �
<br /> � FL15279 R2 C CAC Letter with roof of contract and roof
<br /> , Approved for use in HVHZ: No p P i
<br /> � Approved for use outside HVHZ:Yes of inspection.pdf �
<br /> ! Impact Resistant: N/A FL15279 R2 C CAC W3 Listinq Intertek.pdf E
<br /> ' Design Pressure: +20 PSF/-20 PSF �Quality Assurance Contract Expiration Date �
<br /> Other:The OPTIONAL glazing available for this product ; 05/21/2028 i
<br /> meets the wind load requirements of the building code but Installation Instructions �
<br /> J DOES NOT meet the impact resistant requirement for FL15279 R2 II 101655-Revl2.pdf
<br /> , �windborne debris regions.The product without glazing DOES E Verified By: Intertek Testing Services NA Inc. - ETL/Warnock�
<br /> 3 comply with the impact resistant requirement for windborne Hersey ,
<br /> �debris regions (ref 1609.1.4 FBC), Created by Independent Third Party: �
<br /> a Evaluation Reports �
<br /> , Created by Independent Third Party:
<br /> f �._�� _-_---- -- - -
<br />' 15279.2 002 W3-09 DSIE-1A471: GD1SP, �Gallery/Artistry/Expressions: 1-3/8" Double-skin Insulated
<br /> E GR1SP, GDiLP, GR1LP, AR1SP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.)
<br /> AR1LP, ED1SP, ED1LP Single-Car(up to 9'0"wide) WINDCODEp W3 Garage Door ;
<br /> �_._.._....__ ___________.�... _.____ {
<br /> �Limits of Use Certification Agency Certificate �
<br /> Approved for use in HVHZ: No FL15279 R2 C CAC Letter with oroof of contract and qroof �
<br /> Approved for use outside HVHZ:Yes �of inspection.pdf �
<br /> Impact Resistant: N/A � FL15279 R2 C CAC W3 Listing Intertek.pdf
<br /> Design Pressure: +20 PSF/-21 PSF ' Quality Assurance Contract Expiration Date
<br /> � Other:The OPTIONAL glazing available for this product OS/21/2028
<br /> �meets the wind load requirements of the building code but �Installation Instructions � j
<br /> +DOES NOT meet the impact resistant requirement for � FL15279 R2 II 10395Z-RevOl.pdf I
<br /> �windborne debris regions. The product without glazing DOES � Verified By: Intertek Testing Services NA Inc. - ETL/Warnock€
<br /> �comply with the impact resistant requirement for windborne Hersey i
<br /> debris regions (ref 1609.1.4 FBC). � Created by Independent Third Party• ;
<br /> j Evaluation Reports ;
<br /> --------�-- -___.
<br /> _�WCreated by Independent Third Party: ���
<br /> i
<br /> �15279.3 E 003 W3-09 DSIU-1A171. 9130, �Double-skin Insulated PUR(exterior skin 27 ga. min.; interior;
<br /> I i 9131, 9133, HDP13, HDPF13, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODEp !
<br /> E HDPL13, 7130, 7131, 7133, 8130, �W3 Garage Door i
<br /> !8131, 8133 ` �
<br /> f
<br /> Limits of Use ;Certification Agency Certificate �
<br /> Approved for use in HVHZ: No [ FL15279 R2 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes [of inspection.�df �
<br /> Impact Resistant: N/A ( FL15279 R2 C CAC W3 Listinq Intertek.pdf
<br /> Design Pressure: +20 PSF/-20 PSF �QualityAssurance Contract Expiration Date ;
<br /> Other:The OPTIONAL glazing available for this product � O5/21/2028 �
<br /> meets the wind load requirements of the building code but Installation Instructions E
<br /> DOES NOT meet the impact resistant requirement for FL15279 R2 II 104175-Rev0l.pdf
<br /> windborne debris regions.The product without glazing DOES Verified By: Intertek Testing Services NA Inc. - ETL/Warnock�
<br /> comply with the impact resistant requirement for windborne Hersey
<br /> debris regions (ref 1609.1.4 FBC). Created by IndependentThird Party• �
<br /> Evaluation Reports
<br /> Created by Independent Third Party:
<br /> I 15279,4 + WY�Y �004 W3-16 DSIE-1A171: 2050, 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.;
<br /> ; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Double-Car(9'2"to 16'0"wide) ;
<br /> � �64, 65, 62G, 62LG, 64G, SDP38, WINDCODEp W3 Garage Door �
<br /> , SFL38, SRP38, 134, 135, 136, 6130, I �
<br /> { �6131, 6133
<br /> -- .... L_ _-.�
<br /> �Limits of Use Certification Agency Certificate �
<br /> Approved for use in HVHZ: No FL15279 R2 C CAC Letter with oroof of contract and proof €
<br /> Approved for use outside HVHZ:Yes of insoection.pdf �
<br /> Impact Resistant: N/A FL15279 R2 C CAC W3 Listing Intertek.odf �
<br /> Design Pressure: +20 PSF/-21 PSF QualityAssurance Contract Expiration Date
<br /> Other:The OPTIONAL glazing available for this product OS/21/2028 �
<br /> meets the wind load requirements of the building code but 'Installation Instructions ;
<br /> DOES NOT meet the impact resistant requirement for ( FL15279 Rz II 101820-Revl3.pdf `
<br /> windborne debris regions.The product without glazing DOES � Verified By: Intertek Testing Services NA Inc. - ETL/Warnock�
<br /> comply with the impact resistant requirement for windborne �Hersey �
<br /> https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yWKJZ 1 QRAbbA5BZkl91%2b5XoELm L9p7RMxOvBEhE2g%3d%3d 2/6
<br />
|