<br /> TABLE 2D:STEEL oe CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Teaa-OFF)oa RECOVER
<br /> SYSTEM TYPE D-1:INSULATED,MECHANICALLY ATTACHED ROOF COVER
<br /> Insulation Layer Roof Cover
<br /> System Roof Deck (See Note 14) MDP(psf)
<br /> No.
<br /> Type Attach Membrane Fasteners FastenerSpacing LapWidth LapSpacing SeamWeld
<br /> HPV-X Fastener(steel oniy),MP '
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-SO 1.5-inch
<br /> SC-105 Grade 33 steel or min. or more layers,any 6-inch o.c. 5.5-inch 91-inch o.c. -52.5
<br /> attach VersiWeld Plus (concrete only)Fasteners and outside
<br /> 2,500 psi concrete combination HPV-X Plate
<br /> HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-106 Grade 33 steel or min. or more layers,any 6-inch o.c. 5.5-inch 138.5-inch o.c. -52.5
<br /> attach VersiWeld Plus (concrete only)Fasteners and outside
<br /> 2,500 psi concrete combination HPV-X Plate
<br /> HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-107 Grede 33 steel or min. or more layers,any attach VersiWeld Plus (concrete only)Fasteners and 12-inch o.c. 5.5-inch 42.5-inch o.c. outside -52.5
<br /> +� - ae �
<br /> HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-108 Grade 33 steel or min. or more layers,any 12-inch o.c. 5.5-inch 54.5-inch o.c. -60.0
<br /> attach VersiWeld Plus (concrete only)Fasteners and outside _ _
<br /> 2;500 psi concrete -eombination HPV-X Plate
<br /> HPV-XL Fasteners and HPV-XL
<br /> Min.22 a., e B, Min.1.5-inch,one Plates(steel oniy)or MP 14-10
<br /> g �P Prelim. VersiWeld or 1.5-inch
<br /> SC-109 Grade 33 steel or min. or more layers,any attach VersiWeld Plus (concrete only)or CD-10 6-inch o.c. 5.5-inch� 138.5-inch o.c. outside -60.0
<br /> 2,500 psi concrete combination (concrete only)Fasteners and
<br /> HPV-X Plates
<br /> HPV-X Fasteners(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-110 Grade 80 steel or min. or more layers,any 6-inch o.c. 5.5-inch 138.5-inch o.c. -60.0
<br /> 2,500 psi concrete com6ination attach VersiWeld Plus (concrete only)Fasteners and outside
<br /> HPV-X Plate
<br /> Min.1.5-inch,one or
<br /> more layers,any HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, combination(opcional Loose VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-111 Grade 33 steel or min. 6-inch o.c 5.5-inch 91-inch o.c. -60.0
<br /> for recover)followed laid VersiWeld Plus (concrete only)Fasteners and outside
<br /> 2,500 psi contrete by 3/8-inch Insulfoam HPV-X Plate
<br /> R-Tech EPS orFan-Fold
<br /> HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-112 Grade 33 steel or min. or more layers,any attach VersiWeld Plus (concrete only)Fasteners and 6-inch o.c. 5.5-inch 90.5-inch o.c. outside -67.5
<br /> 2,500 psi concrete combination HPV-X Plate
<br /> HPV-X Fastener(steel only),MP
<br /> Min.22 ga.,type B, Min.1.5-inch,one prelim. VersiWeld or 14-10(concrete only)or CD-10 1.5-inch
<br /> SC-113 Grede 80 steel or min. or more layers,any attach VersiWeld Plus (concrete only)Fasteners and 9-inch o.c. 5.5-inch 54.5-inch o.c. outside -�5.0
<br /> 2,500 psi concrete combination HPV-X Plate
<br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6
<br /> Certificate of Authorization#9503 Revision 5:06/19/2014
<br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 17 of 36