Laserfiche WebLink
Single amily Dwelling <br /> Plan eview Comments <br /> 1. F.F.E. shall be a minimum of 8" ab ve the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply wit R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or ore of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouri g concrete. <br /> 5. Driveways require a R.O.W. use pe it. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be unco ered aid marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be et. <br /> 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with sect on R30�.2 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M 03.4 of the F.B.0 <br /> 12. Water heaters shall comply with se tion P6'07.3 of the .F.B.0 <br /> 13. Foundation supports for A/C units hall be�raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. 1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be n accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in ac ordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not b used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers e required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be r quired i��n new construction that uses fossil-burning heating <br /> or appliances or an attached garag . They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and ele trical shall be separate from unit to unit. This includes all <br /> underground plumbing and electri . <br /> 22. A112008 N.E.C. Codes will be en rced. 'i <br /> 23. Tamper- Resistant Receptacles in cor.dance with 406.11 of the 2008 N.E.0 <br /> 22. In accordance with the Land Deve pmentjCode, lots shall be sodded before final at least 10 <br /> feet around the structure. i <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code(201 ) ' <br /> R.O.W.-Right Of Way <br /> A.D.A.-Americans with Disabiliti s Act ; N.E.C.-National Electric Code(2008) <br /> ; I <br /> . � <br /> � <br />