4 <br /> Florida Building Code Online Page 2 of 3 , ' <br /> Summary of Products � • <br /> FL# Model,Number or Name Description <br /> 4904.1 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and U/S Single Door <br /> U n its - <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 RS C CAC N::OOb110.Ol.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Cuntract Expiration Date <br /> Impact Resistant:Yes 12/31/2014 <br /> Design Pressure:+76.0/-76.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 RS II FL012E.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independe it Third Party: <br /> I ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 RS AE 504A.udf <br /> 3'-0"x 6'-8"max nominal size.When large missile impact Created by Independent Third Party: Yes <br /> resistance is required,hurricane protective system is NOT <br /> required.See DWG-MA-FL0128-OS for details. <br /> 4904.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S and C/S Single Door <br /> U n its <br /> Limits of Use Certification Agency�Certificate <br /> Approved for use in HVHZ:Yes FL4904 RS C CAC NI006110.02.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Cantract Expiration Date <br /> Impa�t Resistant:Yes 12/31/2014 <br /> � Design Pressure: +70.0/-70.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 RS II FLO1Z9.�df <br /> Florida Building Code including the High Velocity Hurricane Verified By; National A=creditation&Management Institute <br />' Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4404 RS AE 503A.udf <br /> 3'-0"x 8'-0"max nominal size.When large missile impact Created by Independerit Third Party: Yes <br />� resistance is required,hurricane protective system is NOT <br /> required.See DWG-MA-FL0129-05 for details. <br /> 4904.3 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and O/S Door w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency I:ertificate <br /> Approved for use in HVHZ:Yes FL4904 RS C CAC NIi)06110.Oi.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2014 <br />' Design Pressure:+55.0/-55.0 Instaliation Instructluns <br /> Other: Evaluated for use in locations adhering to the FL4904 RS II FL0128.�df <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Ac:creditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 RS AE 502A.odf <br /> 12'-0"x 6'-8"max nominal size.When large missile impact Created by IndependentThird Party: Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels,but is required on glazed panels. <br /> See DWG-MA-FL0128-OS for details. <br /> 4904.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Door vi/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Clertificate <br /> Approved for use in HVHZ:Yes FL4904 RS C CAC NIC106110.02.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> i Impact Resistant:Yes 12/31/2014 <br /> Design Pressure:+45.0/-50.0 Installation Instructic�ns <br /> Other:Evaluated for use in locations adhering to the FL4904 RS II FL0124.i�df <br />� Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br />, Zone,and where pressure requirements as determined by Created by Independen�,:Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 RS AE SOlA.o��f <br />' 12'-0"x 8'-0"max nominal size.When large missile impact Created by Independenl:Third Party:Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels,but is required on glazed panels. <br /> See DWG-MA-FL0129-OS for details. <br />� 4904.5 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S w/or�N/o Sidelites <br /> Units <br /> Limits of Use Certifcation Agency Certifcate <br /> Approved for use in HVHZ:Yes FL4904 RS C CAC NI006110.02.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2014 <br /> Design Pressure:+50.0/-45.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the FL4904 RS II FL0129.[�df <br /> Fiorida Building Code including the High Velocity Hurricane Verified By: National Aa:reditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt;,luIwHNbb1S... 7/3 0/2014 <br />