Laserfiche WebLink
i ` <br /> I I <br />, ' I <br /> � - - • •- - • - �- - • -.• � � ' <br /> - - ---�---------�-�------._�.��---------�._.; <br />' These heads have moisture-proof reed switches th t react ; Technical Specifications ' E <br /> to an external magnet fortesting.The magnet test s mulates -•__ .___�..�:__ ___�.._._.___.,___ .____�___________ .___._�.__�..._._, <br /> a 4%to 6%smoke obscuration that places the de ctor in Environmental Considerations I <br /> an alarm condition.This test results in specific LE and RadioFrequency Noalarmorsetuponcriticalfrequenciesin i <br /> alarm circuit responses to indicate: Interference(RFI) therangefrom26MHzto950MHzatfield � <br /> • Detectorwithin calibration standards Immunity: strengthslessthan50V/m ' <br /> • Detector settings outside sensitivity standard RelativeHumidity: Upto93%,non-condensing <br /> • Detectornotoperational Temperature(operating): +32°Fto+100°F(0°Cto+38°C) <br /> This test is especially useful in environmentally un table or <br /> unclean areas. MechanicalProperties <br /> Sensitivity voltage test Color: Bonewhite <br /> These detector heads have a socket that accepts t e D1005 Dimensions(diameterx D): 4 in.x 1.25 in.(10.2 cm x 3.2 cm) <br /> Test Cable.The D1005 connects to the detector h ad and powerRequirements <br /> allows a voltmeter to read the sensitivity of the d ice. <br /> LEDs Current Two-wire:depends on control panel that must limit the <br /> The D285 and D285TH have a built-in LED that fla hes to �alarm): alarmcurrentto 100mAmaximum <br /> Four-wire:depends on detector base;refer to pertinent <br /> indicate the device is powered.The LED latches o steady basespecifications <br /> in an alarm condition. Current Two-wire:0.08 mA at 12 VDC;0.09 mA at 24 VDC <br /> (standby): Four-wire(D293E):4 mA at 12 VDC or 24 VDC <br /> ,-- -�-----�---.�.—-------------__-___ __—.__---- <br /> RMS Ripple 25%of DC input <br /> � Certifications and Approvals ,� ; (maximum): <br /> ��_...�.--.. _.______...__.___..�-- --.__.._.__... _._�_....__.,..______ <br /> ___�__w._a <br /> Voltage(in- Two-wire:8.5 VDC to 33 VDC <br /> Region Certification put): Four-wire:l0 VDC to 30 VDC <br /> USA UL UROX:Smoke-AutomaticFire etectors Trademarks <br /> (UL268andA),UROX7:Smoke- utomatic Trademark names are used throughout this document. In <br /> FireDetectorsCertifiedforCan da most cases,these designations are claimed as trademarks <br /> (cULus) or registered trademarks in one or more countries by their <br /> CSFM 7272-1615:134 respective owners.Rather than placing a trademark symbol <br /> NYC-MEA 274-93-E,Vol.VII in every occurrence of a trademark name, Bosch Security <br /> Systems, Inc. uses the names only in an editorial fashion <br /> MSFM and to the benefit of the trademark owner with no intention <br /> Hong Kong HKFSD of infringing the trademark. <br /> Chamber Check is a registered trademark of Bosch Security Systems in the <br /> United States. <br /> ;Installation/Configuration Notes f <br /> Note Smoke detectors are intended for de ection <br /> circuits that protect people.Heat det ctors are <br /> appropriate for circuits that protect roperty. <br /> Mounting <br /> The D285 smoke detector head and D285TH smo e and <br />' heat detector head are parts of a compound devi e.The <br /> detector base installs over a back box and contai s all the <br /> wiring.The detector head attaches to the base b aligning <br /> the head with the base and turning it clockwise. o tools <br /> are required for installation other than the hex k used to <br /> tighten the optional tamper screw. <br /> Wiring <br /> The terminal block accepts up to 12 AWG (2.3 m ) wire. <br />