My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6747 NORTHLAKE DR
Zephyrhills
>
Building Department
>
Building Plans
>
6747 NORTHLAKE DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2017 11:07:33 AM
Creation date
3/1/2017 11:00:04 AM
Metadata
Fields
Template:
Building Plans
Street #
6747 NORTHLAKE DR
Location
SILVER OAKS
Contractor
RYMAN CONSTRUCTION
Owner
SMITH
Building Plans - Permit #
4020B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , , <br /> .- . ARTICLE 250—GROUNDING 70-1'27 7��1 Z8 NATIONAL.ELECTRICAL CODE ' � <br /> jumper shall be sized in accordance with Table 250=95 using the rating of (b) Metal Frame of the Bullding. The metal frame of the building,where <br /> the circuit that may ener�ize�the piping. effectively grounded. �` <br /> The equipment groundmg conductor for the circuit that may energize the �FpI�: Effectively grounded means intentionally wnnected to earth through a <br /> piping shall be permitted to serve as the bonding means. ground connection or connections of sufficientty low impedance and having sug'i- <br /> (FPI�: Bonding all piping and metal air ducts within the premises will provide cient current-carrying capacity to•prevent the buildup of voltages that may result in <br /> additional safety. , undue hazard to connected eqwpment or to persons. <br /> (c) Concrete-Encased ElecVode..An electrode encased by at least 2 <br /> H:Grourniing Electrode System inches(50.8 mm)of concrete,.located within and near the bottom�of a con- <br /> crete foundation or footing that is in d'uect contact with the earth,consist- <br /> 250-Si. Grounding Electrode System. If available on the premises at �g of at least 20 feet (6.1 m) of one or more baze or zinc gatvanized or <br /> each building or structure seived,each item(a)through(d)below,and anyl other electrically conductive coated steel reinforcing bars or rods of not <br /> made electrodes in accordance with Sections 250-83(c) and (d), shall be less than �/2 inch (12.7 mm) diameter, or consisting of at least 20 feet <br /> bonded together to form the grounding electrode system. Interior metal� (6.1 m)of bare copper conductor not smaller than No.4. <br /> water piping located more than 5 feet(152 cm)from the point of entrance <br /> to the building shall not be used as a conductor to interconnect the elec- (d) Ground R(ng. A ground ring encircling the building or structure, in <br /> trodes and the grounding electrode conductor.The bonding jumper shall be direct contact with the earth at a depth below earth surface not less than <br /> installed in accordance with Sections 250-92(a) and (b), shall be sized in 2�/2 feet(762.mm),consisting of at least 20 feet(6.1 m)of.bare wpper con- <br /> accordance with Section 250-94, and shall be connected in the manner� ductor not smaller than No.2. <br /> specified in Section 250-115.The unspliced grounding electrode conductor <br /> shall be pernutted to run to any convenient grounding electrode available 250-83. Made and.Other Electrodes. Where none of the electrodes s�ec- <br /> in the grounding electrode system. It shall be sized for the largest ground- �ed in Section 250-81 is available,one or more of the electrades specified <br /> ing electrode wnductor required among all the available electrodes. in(b)throu�(d)below shall be used.Where practicable,�tade electrodes <br /> Fxception No. 1: It shall be permitted to splice the grounding e[ectrode shall be em edded below pertnanent moisture level.Made electrodes shall <br /> conductor by means of irreversible compression-type connectors listed for be free from nonwnductive coatings,such as paint or enamel.Where more <br /> the u ose or the e.xothermic weldin rocess. than one electrode is used,each electrode of one grounding system(includ- <br /> P �P gP ing that used for lightning rods)shall not be less than 6 feet(1.83 m)from <br /> Exception No. 2: In industrial and commercial buildings where condi- any other electrode of another grounding system. ' <br /> tions of mairttenance and supervision ensure that only qualifted persons ���: �,o or more electrodes that aze effectively bonded together are to be <br /> will service the installation and the entire length of the interior metal water treated as a singie electrode'system in this sense. <br /> pipe that is being used for the conductor is exposed. <br /> (FPN): See Section 547-8 for special grounding and bonding requirements.for � (a) Metal Underground Gas Plping System. A metal underground gas <br /> agncultural buildings. piping system shall not be used as a grounding electrode. <br /> a Metal vnder round Water Pi e A metal under ound water i e in �b) Other Local Metai Underground Systems or Structures. Other local <br /> ( ) 9 P • �' P P metal underground systems or structures, such�as,piping systems and <br /> direct contact with the earth for 10 feet (3.05 m) or more (including any underground Eanks. <br /> metal well casing effectively bonded to the pipe) and electncally continu- c Rod and Pi e Electrodes. Rod and i e electrodes shall not be less <br /> ous(or made electrically continuous by bond'mg around insulating�oints or � � p P P <br /> sections or insulating pipe).to the points of connection of the grounding than 8 feet(2.44 m)in length and shall cons�st of the following materials, <br /> electrode conductor and the bonding conductors.Continuity of the ground- �d shall be installed in the following manner: <br /> ing path or the bonding connection to interior piping shall not rely on water (1) Electrodes of pipe or conduit shall not be smaller than 3/a-inch trade �i <br /> meters. A metal underground water pipe shall be supplemented by an size and,where of iron or steel,shall have the outer surface galvanized or <br /> additional electrode of a type specified in Section 250-81 or in Section 250- otherwise metal-coated for conosion protection. <br /> 83. The supplemental electrode shall b� pemutted to be bonded to the (2) Electrodes of rods of iron or steel shall be at least 5/8 inch(15.87 mm) <br /> grounding electrode conductor, the grounded service-entrance conductor,I_� diameter. Stainless steel rods less than 5/$ inch (15.87 mm) in diameter, <br /> the grounded service raceway,or any grounaed service enclosure. �nonferrous rods,or their equivalent shall be listed and shall not be less than <br /> Wl�ere the supplemental electrode is a made electrode as in Section 250- �/Z�ch(12.7 mm)in diameter. ' <br /> 83(c)or(d), that portion of the bonding jumper that is the sole connection �3) The electrode shall be installed such�that at least 8 feet(2.44 m)of <br /> to the supplemental prounding electrode shall not be required to be larger length is in contact with the soil. It shall be driven to a depth of not less <br /> than No. 6 copper wue or No.4 aluminum wire. than 8 feet (2.44 m) except that,where rock bottom is encountered, the <br /> Fxception: Tlae supplemental electrode shall be permitted to be bonded electrode shall be driven at an oblique angle not to exceed 45 degrees from <br /> to the interior metal water piping at arry convenient point as covered in I the vertical or shall be buried in a trench that is at least 2�/Z feet(762 mm) <br /> Section 250-81, Fxception No. 2. deep.The upper end of the electrode shall be$ush with or below ground <br />
The URL can be used to link to this page
Your browser does not support the video tag.