My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36404 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36404 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 12:38:53 PM
Creation date
1/21/2025 3:30:49 PM
Metadata
Fields
Template:
Building Plans
Street #
36404
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
5688
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�I <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1.1 <br />FIRST FLOOR PLAN <br />1.2 <br />SECOND FLOOR PLAN <br />2.1 <br />EXTERIOR ELEVATIONS - FRONT & LEFT <br />2.2 <br />EXTERIOR ELEVATIONS - REAR & RIGHT <br />3 <br />ELECTRICAL PLAN <br />4 <br />ROOF PLAN <br />5 <br />FOUNDATION PLAN <br />6.1 <br />FLOOR FRAMING PLAN <br />6.2 <br />ROOF FRAMING PLAN <br />ABBREVIATIONS <br />7 <br />LINTEL PLAN & DETAILS <br />SN <br />STRUCTURAL NOTES <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />RA or R/A or R.A. Return Air <br />SN 1 <br />DETAILS <br />ABV or Abv. <br />Above <br />FUR or Fir. Floor <br />RAD or Rad. <br />Radius <br />S3 — <br />— - <br />DETAILS <br />AC or A/C Air -Conditioner <br />FLR SYS or Fir Sys Floor System <br />RAG or Rag. Return Air Grill <br />ADJ orADJ. <br />AFF or A.F.F. <br />Adjustable <br />Above Finished Floor <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />REC or Rec. <br />RECEPT <br />Recessed <br />Receptacle <br />S4 <br />DETAILS <br />S5 <br />- --- -- -- <br />DETAILS <br />AHU or A.H.U. Air Handler Unit <br />FIR DR French Door <br />REF or Ref. Refrigerator <br />ALTorALT. <br />BC <br />Alternate <br />Base Cabinet <br />FRT Front <br />FT or Ft. Foot/ Feet <br />REINF <br />REQD or Req'd. <br />Reinforcing <br />Required <br />S6M <br />DETAILS <br />ST <br />STAIR DETAILS <br />BF Bifold Door <br />FTG or Ftg. Footing <br />RM or Rm. Room <br />SK SH or Bk Sh <br />BLK or BLK. <br />BookShelf <br />Block <br />FXD GL Fixed Glass <br />GALV or Galv. Galvanized <br />RND or Rnd. <br />RO or R.O. <br />Round <br />Rough Opening <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />BLW or BLW. Below <br />GC or G.C. General Contractor <br />RS, R/S, R/SH or R&S Rod and Shelf <br />BM or Bm. <br />BOT or Bot. <br />BP or B.P. <br />Beam <br />Bottom <br />Bypass (door) <br />GFI or G.F.I, Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />SC <br />SD or SD. <br />SGD <br />Solid Core <br />Smoke Detector <br />Sliding Glass Door <br />D2 <br />- —--— <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />BRG or BRG, <br />C <br />Bearing <br />Carpet <br />HB Hose Bibb <br />HC Hollow Core <br />SH or Sh. <br />SHT <br />Shelves <br />Sheet <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />CAB <br />CIR or Cir. <br />Cabinet <br />Circle <br />HDRorHdr. Header <br />HGT or Hgt. Height <br />SHWRorShwr. <br />SL or S.L. <br />Shower <br />Side Lights <br />PA1.1 <br />PRODUCTAPPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />CJ or C/J Control Joint <br />HH or H.H. Hand Held (plumbing faucet) <br />SPECS or SPECS. Specifications <br />CLG or Gig. <br />CMU <br />Ceiling <br />Concrete Masonry Unit <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />SPF or S.P.F. <br />SQ FT or SF or S.F. <br />Spruce Pine Fir <br />Square Foot (feet) <br />PA1.3 <br />_ --- <br />PRODUCT APPROVAL NUMBERS <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COFF or Coff. Coffered or Tray Ceiling <br />ILO In Lieu Of <br />SQ or Sq. Square <br />COL or Col. <br />COMM or Comm. <br />Column <br />Community <br />INSUL or Insul. insulation <br />INTorInt. Interior <br />STO <br />SW or S.W. <br />Storage- <br />Shear Wall <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.2 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMP or Comp. Compressor <br />KMWALL or K/Wall Kneewali <br />SYP or S.Y.P. Southern Yellow Pine <br />�' O <br />CONN or CONN, <br />CONTorCont, <br />Connection <br />Continuous <br />KS or K.S. Knee Space <br />LAUNorLaun. Laundry <br />TB <br />TEMP or Temp. <br />Towel Bar <br />Tempered <br />_ _ _ _ _ <br />/ / / / O O <br />— <br />_ <br />— <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CSMT <br />Casement <br />LAV or Lay. Lavatory <br />THIKN orThik'n. <br />Thicken <br />SH1,4 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CT or C.T. <br />Ceramic Tile <br />LF or L.F. Linear Ft. <br />TOB or T.O.B. <br />Top of Block <br />SH 1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />D or D. Dryer <br />LL Lintel Length <br />TOM or T.O.M. Top of Masonry <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ' <br />DB <br />Door Bell <br />LT Laundry Tub <br />TOP or T.O.P. <br />Top of Plate <br />DBL or Dbl. <br />Double <br />MAS or Mas. Masonry <br />TP <br />Toilet Paper Holder <br />DCF <br />DEC or Dec. <br />Decorative Cementitious Finish <br />Decorative <br />MAX or Max Maximum <br />MC Medicine Cabinet <br />TR <br />TRANS WOW or Trans. <br />Towel Ring <br />Transom Window <br />1^� <br />r7 [71 [71 r7MO <br />DED or Ded. <br />DIA or Dia. <br />DISP or Disp. <br />Dedicated (outlet) <br />Diameter <br />Disposal <br />MFR or Mfr. Manufacturer <br />MGT Management (room) <br />MIN or Min Minimum <br />TYP or Typ. <br />UC or u.c. <br />UCL <br />Typical_-- <br />Under Counter <br />Under Cabinet Lighting. <br />1 i 1 1 <br />El El El D <br />DIST or Dist. Distance <br />MIR or Mir. Mirror <br />UNO or U.N.O. Unless Noted Otherwise <br />DMF <br />DS or D.S. <br />DTL <br />Decorative Masonry Finish <br />Drawer Stack <br />Detail <br />ML or M.L. Microlam <br />MONO Ior C Mono Monolithic <br />MW or MICRO or Micro. Microwave <br />V or v. <br />VB <br />VERT or Vert. <br />Valve (shower or tub/shower) <br />Vanity Base <br />Vertical <br />a ❑ <br />-- <br />-- <br />-- <br />--- - -------------- -- — <br />_� <br />DV or D.V. <br />DD.V.P. <br />Dryer Vent <br />DiValve (plumbing) <br />NTS or N.T.S. Not to Scale <br />OE or O.E. Owner's Entry <br />VL or V.L. <br />VTR VTE <br />Versalam <br />Vent through Roof I Exterior <br />a <br />�- ------ - - <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />DW or D.W. Dishwasher <br />OPNGorOpn'g. Opening <br />Worw Washer <br />EID <br />EA or Ea. <br />ELEC or Elec. <br />Each <br />Electrical <br />OPT or Opt. Optional <br />PC Pull Chain <br />W/orw/ <br />WA or W.A. <br />With <br />Wedge Anchor <br />FOR SINGLE STORY HOMES <br />ELEV or Elev. <br />EQ <br />EWorE.W. <br />Elevation <br />Equal <br />Each Way <br />PED or Ped. Pedestal <br />PH Phone <br />PKTorPkt. Pocket(Door) <br />WC or WIC or W.C. <br />WD or Wd <br />WOW HDR or WOW. HDR. <br />Water Closet (toilet) <br />Wood <br />Window Header <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />EXP or tarp. <br />EXTorExt. <br />FBC <br />Expansion <br />Exterior <br />Florida Building Code <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />WH or W.H. <br />WIC or W.W. <br />WM or W.M. <br />Water Heater <br />Walk-in Closet <br />Wall Mounted (plumbing fixture) <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />FDNorFdn. <br />Foundation <br />PLTHTorPit. Ht. Plate Height <br />WP <br />WaterProof(ing) <br />IS SIGNED AND SEALED OR WHILE <br />FFB <br />Finsh Floor Break <br />PSF Pounds per square foot <br />WS <br />Water Softener <br />CURRENT CODE 1S VALID <br />FG <br />FIN <br />FIN FLR or FF or Fin. Fir. <br />Fiberglass (Shower Pan) <br />Finished <br />Finished Floor <br />PT or P.T. Pressure Treated <br />PWorP.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />WWF <br />Welded Wire Fabric (Mesh) <br />REV. 06.23.22 <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titieblock of these <br />documents that these documents be accurate, providing Licensed <br />08/23/1 2 1.00 NEW BASE PLAN <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />07/30/ 15 <br />1.1 <br />2015 NEW CODE UPDATE <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />05/09/18 <br />2.0 <br />FBC 2017 CODE UPDATES <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />12/ 19/20 <br />3.0 <br />FBC 2020 CODE UPDATE <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />207A <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />d <br />Im <br />Ja ata <br />aaa0 <br />`° <br />c�J <br />AIR <br />V-- <br />03 ea. <br />;,� ����\\\\Qllilfttl►1/Irj�i <br />�� `�'.•' Ns . •% <br />j� O� 4c� <br />r <br />est � ,tet1��4 <br />To the best of the Engineer's knowledge, infonnation and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />9) <br />W d OE <br />Q 'O N U <br />p <br />0 j n OD w <br />CN 0 <br />5 a_ <br />Z coC °' n <br />r m o <br />0 <br />W Q t6 r (O 0 Y <br />0" ' w <br />W 0) m <br />d G <br />-� LO N ZIL <br />N O U U Ix 0 0 <br />13 <br />W 00 <br />0 _F <br />Z N M <br />0 <br />a <br />M <br />U) <br />N z <br />C9 0 <br />LL <br />U � <br />�O`^ ,,, o <br />V) L N <br />) <br />map L'i <br />— 8 <br />II c) U) <br />Q Y <br />_ • <br />o <br />CC) <br />w <br />M <br />z <br />Z <br />J <br />U— <br />ce E <br />o <br />=o <br />0 0 <br />g <br />Q'N <br />E U <br />'Z <br />OU <br />zo <br />on: <br />00 <br />I— r0 <br />O <br />X <br />az <br />0 <br />O , <br />aZ <br />N I� <br />¢o <br />r� <br />U.) <br />_ <br />pY <br />ym <br />o � <br />z <br />ZU <br />J <br />¢ ° <br />SW <br />g Z <br />lq <br />Q <br />$ n50 <br />�� <br />W <br />U <br />�o <br />�z <br />o <br />¢w <br />w <br />C7 F <br />�o <br />a = <br />IIIIIIIIIII� <br />00 <br />© <br />co <br />J <br />0 <br />m <br />m <br />CID co <br />C) <br />v CIO <br />C) <br />Co <br />LO <br />-2 <br />0 <br />.� cc N <br />C) <br />d O <br />LO <br />N <br /><C <br />T- <br />E <br />�_ M N <br />° <br />Z <br />Z <br />r <br />O alai <br />c <br />d0 <br />16 a a <br />JOB <br />NO: 22-12356 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.