Laserfiche WebLink
List Of Abbreviations <br />A <br />A/C <br />AIR CONDITION <br />E <br />EL <br />ELEVATION <br />L <br />LAV <br />LAVATORY <br />S <br />Sc <br />SOLID CORE <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />LBL <br />LABEL <br />SCHED <br />SCHEDULE <br />ACT <br />ACOUSTICAL CEILING TILE <br />ELEV <br />ELEVATOR <br />LBS <br />POUNDS <br />SCP <br />SCUPPER <br />AD <br />ADJUSTABLE, ADJACENT <br />EMER <br />EMERGENCY <br />LF <br />LINEAR FEET <br />SD <br />SOAP DISPENSER <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />LT WT <br />LIGHT WEIGHT <br />SEAL <br />SEALANT <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />SECT <br />SECTION <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />M <br />MAS <br />MASONRY <br />SF <br />SQUARE FEET <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />MAX <br />MAXIMUM <br />SHT <br />SHEET <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />MECH <br />MECHANICAL <br />SIM <br />SIMILAR <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />MFR <br />MANUFACTURER <br />SPEC <br />SPECIFICATION <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />MH <br />MANHOLE <br />SS <br />STAINLESS STEEL, <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />MIN <br />MINIMUM <br />SERVICE SINK <br />AUTO <br />AUTOMATIC <br />MIN <br />MINIMUM, MINUTE <br />STD <br />STANDARD <br />F <br />FACP <br />FIRE ALARM <br />MISC <br />MISCELLANEOUS <br />STL <br />STEEL <br />B <br />B 0 <br />BOTTOM OF <br />CONTROL PANEL <br />MLDG <br />MOLDING <br />STOR <br />STORAGE <br />BD <br />BOARD <br />FD <br />FLOOR DRAIN <br />MO <br />MASONRY OPENING <br />STRUC <br />STRUCTURAL <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />MR <br />MOISTURE RESISTANT <br />SUSP <br />SUSPENDED <br />BM <br />BEAM <br />FIN <br />FINISHED <br />MTD <br />MOUNTED <br />SY <br />SQUARE YARD <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />MTL <br />METAL <br />BTM <br />BOTTOM <br />FR <br />FIRE RESISTANT <br />MUL <br />MULLION <br />T <br />T <br />TREAD <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />T&G <br />TONGUE & GROOVE <br />WOOD TREATMENT <br />N <br />NIC <br />NOT IN CONTRACT <br />TBL <br />TABLE <br />C <br />CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />NOM <br />NOMINAL <br />TELE <br />TELEPHONE <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />NTS <br />NOT TO SCALE <br />TEMP <br />TEMPERED <br />Cl <br />CAST IRON <br />FURR <br />FURRING <br />THK <br />THICK <br />CJ <br />CONTROL JOINT <br />FUT <br />FUTURE <br />0 <br />OC <br />ON CENTER <br />TILT <br />TOILET <br />CL <br />CENTER LINE <br />OD <br />OUTSIDE DIAMETER <br />TO <br />TOP OF <br />CLG <br />CEILING <br />G <br />GA <br />GAUGE <br />OPP <br />OPPOSITE <br />TPD <br />TOILET PAPER <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />OVFL <br />OVERFLOW <br />DISPENSER <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />TS <br />TUBE STEEL <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />P <br />PL <br />PLATE <br />TV <br />TELEVISION <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />PLAM <br />PLASTIC LAMINATE <br />TYP <br />TYPICAL <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />PLASTER <br />COL <br />COLUMN <br />pLg� <br />PLUMBING <br />U <br />LION <br />UNLESS OTHER- <br />CONC <br />CONCRETE <br />H <br />HB <br />HOSE BIBB <br />PLWD <br />PLYWOOD <br />WISE NOTED <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />PNL <br />PANEL <br />UTIL <br />UTILITY <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />PR <br />PAIR <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />PREFAB <br />PREFABRICATED <br />V <br />VB <br />VINYL BASE <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />PT <br />POINT <br />VCT <br />VINYL COMPOSITE TILE <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />PT <br />PRESSURE TREATED <br />VERT <br />VERTICAL <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />PTD <br />PAPER TOWEL DISPENSER <br />VEST <br />VESTIBULE <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />PVC <br />POLY VINYL CLORIDE <br />VIF <br />VERIFY IN FIELD <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />VTR <br />VENT THRU ROOF <br />& AIR CONDITIONING <br />Q <br />QT <br />QUARRY TILE <br />VWC <br />VINYL WALL COVERING <br />D <br />DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />R <br />R <br />RADIUS, RISER, <br />W <br />W <br />WIDTH <br />DET <br />DETAIL <br />I <br />ID <br />INSIDE DIAMETER <br />THERMAL RESISTANCE <br />W/ <br />WITH <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />RD <br />ROOF DRAIN <br />W/O <br />WITHOUT <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />RECP <br />RECEPTACLE <br />WC <br />WATER CLOSET <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />REF <br />REFERENCE <br />WD <br />WOOD <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />REFR <br />REFRIGERATOR <br />WH <br />WATER HEATER <br />DN <br />DOWN <br />INV <br />INVERT <br />REG <br />REGLET <br />WP <br />WATERPROOF <br />DS <br />DOWNSPOUT <br />REINF <br />REINFORCEMENT <br />WT <br />WEIGHT <br />DWG <br />DRAWING <br />J <br />JAN <br />JANITOR <br />REQ <br />REQUIRED <br />WWF <br />WELDED WIRE FABRIC <br />JB <br />JUNCTION BOX <br />REV <br />REVISION <br />WWM <br />WELDED WIRE METAL <br />E <br />EA <br />EACH <br />JT <br />JOINT <br />RM <br />ROOM <br />EB <br />EXPANSION BOLT <br />L <br />RND <br />ROUND <br />Y <br />YD <br />YARD <br />EIFS <br />EXTERIOR INSULATING <br />L <br />LENGTH <br />RO <br />ROUGH OPENING <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />RTU <br />ROOF TOP UNIT <br />EJ <br />EXPANSION JOINT <br />Legend <br />X -- GRID DESIGNATION <br />102 ROOM NUMBER <br />102A DOOR NUMBER <br />® WINDOW TYPE <br />O2 STOREFRONT TYPE <br />WALL TYPE <br />O KEY NOTE <br />® REVISION NUMBER <br />TO SOMETHING ELEVATIONS TAGS <br />XX'-XX" <br />;N- <br />SPOT ELEVATION TAG <br />• <br />N NORTH ARROW <br />BUILDING SECTION <br />A301-2 A301-2 <br />SHEET NUMBER SECTION NUMBER <br />I I WALL SECTION <br />A302-3 <br />SHEET NUMBER SECTION NUMBER <br />A501-6 SECTION DETAIL <br />SHEET NUMBER DETAIL NUMBER <br />A888-88 DETAIL REFERENCE <br />SHEET NUMBER DETAIL NUMBER <br />EXTERIOR ELEVATION <br />A201-2 MARKERS <br />SHEET NUMBER ELEVATION NUMBER <br />1 <br />a <br />4 A401 2 INTERIOR ELEVATION <br />MARKERS <br />SHEET NUMBER 3 ELEVATION NUMBER <br />BRICK <br />! ° .. CONCRETE <br />PLYWOOD <br />GYPSUM <br />BOARD <br />0e, <br />DRAINAGE <br />FILL <br />MASONRY <br />���/���/ COR PACTED <br />EARTH <br />STEEL <br />RIGID <br />INSULATION <br />= .... <br />MR <br />BOARD <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL <br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS, THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR <br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS A <br />FULL FIRE ALARM SYSTEM. THESE SYSTEMS SHALL BE MODIFIED <br />AS NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED <br />TENANT SPACES. THE CONTRACTOR SHALL SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE <br />LOCAL JURISDICTION FOR PERMITTING. NO WORK ON THE FIRE <br />PROTECTION SYSTEMS SHALL TAKE PLACE UNTIL THE REQUIRED <br />PERMITS ARE OBTAINED BY THE FIRE PROTECTION SUB <br />CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANY <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity MapNTS <br />7864 GALL BLVD, ZEPHYRHILLS, FLORIDA <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT <br />5335 8TH STREET (813) 780-0020 - PHONE <br />ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX <br />ADOPTED CODES: <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (WI 2009 AMENDMENTS) <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009 AMENDMENTS) <br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) <br />FUEUGAS: FLORIDA BUILDING CODE, FUEUGAS - 2007 (WI 2009 AMENDMENTS) <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />ENERGY: FLOR DA BUILDING CO EI,D UTCHAPTER 11 - FLORAA DIING - 200CCESSIBILI7 (W/0DE FOR BUILDING CONSTRUCTION). <br />2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES <br />ACTUAL HEIGHT 35'-0" - ONE STORY <br />MAXIMUM AREA 12,500 SF <br />ACTUAL AREA 8,600 SF <br />A-o <br />V <br />Hies � y �a <br />cL,L,Y of ZEPHYR �� SHEET NO. <br />PLANS EypMMF_R <br />ARCHITECTURAL <br />NOTE: <br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY <br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS <br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />"M•1 <br />CLIENT: PRIMERICA GROUP ONE, INC. <br />STRUCTURAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />3629 MADACA LANE <br />ENGINEER: <br />1925 PROSPECT AVE <br />TAMPA, FL. 33618 <br />ORLANDO, FL 32814 <br />(813) 933-0629 PHONE <br />(407) 661-9100 PHONE <br />(813) 935-3420 FAX <br />(407) 661-9101 FAX <br />CONTACT: ADAM ROBINSON <br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC <br />MECHANICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ENGINEER: <br />1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CIVIL AVID GROUP <br />ELECTRICAL <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 8659 BAYPINE ROAD, STE 304 <br />ENGINEER: <br />1925 PROSPECT AVE <br />JACKSONVILLE, FLORIDA 32256 <br />ORLANDO, FL 32814 <br />(904) 737-4001 PHONE <br />(407) 661-9100 PHONE <br />(904) 252-7030 FAX <br />(407) 661-9101 FAX <br />A901 <br />A902 <br />A903 <br />A904 <br />Vanilla Shell at Zephyr Commons �\ � <br />Tenant Space D2 in Building D <br />7864 Gall Blvd, Zephyrhills, FL <br />SPACE D2 (AREA OF INTR. WORK) <br />Scope of Work <br />1. The scope is limited to tenant space D2 in Bldg D. The space is 20' x 70' (outside faces of exterior walls and centers of demising walls). <br />2. The scope does not include any work related to the parking lot, landscaping, site utilities, site drainage, site lighting, or any other site features. <br />3. The scope does not include any work on any of the buildings in the shopping center other than Bldg D. <br />4. The scope does not include any work to the sidewalks, hardscape areas, or landscape areas immediately adjacent to any of the buildings. <br />5. The scope does not include any work to the finishes, awnings, stone work, or decorative trim on the exterior elevations of any of the buildings. <br />6. The scope does not include any work to the storefront systems, decorative windows, front storefront doors, or rear hollow metal doors on any <br />of the buildings. <br />7. The scope does not include any work on the existing roof system other than what is required to add an exhaust fan and a vent for the new <br />restroom. The scope does not include any work on the shingle roofs or on the roof drainage systems. <br />8. The scope does not include any work on the front framed wall. The existing 1 hour fire rating on the front framed wall shall be maintained. <br />9. The scope does not include any work on the existing tenant demising walls other than what is required to install the new restroom. The <br />existing 1 hour fire ratings shall be maintained. <br />10. The scope includes adding sheathing over furring and insulation on the inside of the rear masonry wall inside the restroom only. The rest of <br />the rear wall will be left as exposed masonry with no finish. <br />11. The scope includes providing a new fire extinguisher as required by code. <br />12. The scope includes installing a new restroom as shown on the plans. <br />13. The scope includes new 2' x 4' ACT ceilings at 10'-0" AFF. The ceilings will not have insulation. <br />14. The scope does not include any work on the foundations, columns, beams, joists, roof deck, or trusses. The scope does not include any <br />structural work on the existing masonry or framed walls. <br />15. The scope includes saw -cutting the existing floor slab as needed to provide new plumbing. <br />16. The scope includes re -pouring any portion of the existing slab that is saw -cut. It also includes pouring a new slab in the area of the existing <br />slab leave out at the rear of space D2. <br />17. The existing building has a fire sprinkler system with the heads turned up. The scope includes turning down the sprinkler heads and <br />repositioning them as needed to fit the ceiling layout. The design of the sprinkler system will be handled by the contractor through their signed <br />and sealed shop drawings. The contractor shall be responsible for determining the exact locations of all sprinkler heads and for coordinating <br />with all other disciplines. The contractor shall be responsible for providing signed and sealed shop drawings as required for permitting. <br />18. The scope does not include any work to any underground sanitary lines other than what is required for connection of new sanitary lines. The <br />scope does not include any work to any existing dean outs. <br />19. The scope includes removal of any unused portion of existing above ground stub -ins for space D2. <br />20. The scope includes connecting a new 4" sanitary line to the existing line and extending it as needed to serve the new restroom. <br />21. The scope does not include any floor drains. The scope does not include any stub outs for future tenant connection to the sanitary system. <br />TITLE ON SHEET PERMIT SET <br />2011_03-04 <br />22. The scope includes new vent piping and a new vent through the roof. The scope does not include any stub outs for future connection to <br />the vent pipes by the tenant. <br />23. The scope does not include any work to the water meter, the cold water main, or any of the valves. The scope does not include any <br />work to the cold water branch line other than what is required for connection of new cold water piping. <br />24. The scope includes connection of a new 1" cold water line to the existing branch line. The new line shall be extended as needed to <br />serve the new restroom. <br />25. The scope does not include any provisions for hot water or any stub outs for future tenant connection to the cold water system. <br />26. The scope includes plumbing fixtures as shown on the plans. <br />27. The scope does not include any work related to grease or gas. <br />28. The scope does not include any work to the existing 5 ton RTU above space D2 other than what is required to connect new HVAC <br />ducting. The scope does not include work for any other RTUs. <br />29. The scope does not include any work to any of the existing condensate lines. <br />30. The scope includes providing a full HVAC system as shown on the plans. <br />31. The scope includes providing an exhaust fan in the restroom that is vented to the roof. <br />32. The scope does not include any work to the building transformer, the secondary conduit, the secondary wire, the main disconnect, the <br />wireway, the tenant meter, or the tenant disconnect. <br />33. The scope includes new wire to be pulled from the existing tenant disconnect to the new tenant panel via the existing empty conduit. <br />34. The scope includes providing a new 200 amp,120 1208 volt, 3 phase, 42 pole electrical panel. <br />35. The scope includes new power receptacles as shown on the plans. <br />36. The scope does not include any changes to the existing sign junction box on the front of the building over the storefront. The scope <br />does include wiring this junction box to the new tenant panel. <br />37. The scope includes wiring the existing RTU and all other components of the HVAC system to the new tenant panel. <br />38. The scope does not include any changes to the decorative sconce light fixtures on the front of the building. <br />39. The scope does not include any changes to the existing wall mounted light fixture on the rear of the building. The scope does include <br />wiring this light fixture to the new tenant panel via a light switch. <br />40. The scope includes providing exit and emergency light fixtures as shown on the plans. <br />41. The scope includes providing ceiling mounted 2' x 4' light fixtures as shown on the plans. <br />42. The scope does not include any changes to the existing telephone system. The existing conduit stubbed into the rear of the space <br />shall remain as is. <br />43. The existing building has a fire alarm system. The scope includes modifying the system as needed to provide a code compliant fire <br />alarm system in space D2. The design of the alarm system will be handled by the contractor through their signed and sealed shop <br />drawings. The contractor shall be responsible for determining the exact locations of all fire alarm components and for coordinating with <br />all other disciplines. The contractor shall be responsible for providing signed and sealed shop drawings as required for permitting. <br />Drawing Index <br />COVER SHEET <br />X <br />PROJECT SITE PLAN <br />X <br />PLANS <br />X <br />DETAILS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />:IRE PROTECTION <br />FIRE SPRINKLER NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE D2. ALL MODIFICATIONS TO THE SPRIKLER SYSTEM SHALL BE <br />DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING <br />P101 <br />MECHANICAL <br />M101 <br />ELECTRICAL <br />E101 <br />E501 <br />FIRE ALARM <br />PLUMBING FLOOR PLAN & GENERAL INFORMATION X <br />MECHANICAL FLOOR PLAN & GENERAL INFORMATION X <br />ELECTRICAL PLANS RISER & SCHEDULE X <br />ELECTRICAL SPECIFICATIONS X <br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED FOR SPACE D2. ALL MODIFICATIONS TO THE FIRE ALARM <br />SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />�--� <br />U <br />c <br />N <br />� U <br />LL <br />� <br />Uco <br />0 <br />m o� <br />z <br />g <br />QQ, <br />`- <br />o <br />UJ X <br />•� <br />Q <br />U <br />Q LL <br />U <br />CD <br />w <br />C)co <br />ar- <br />CD <br />r l <br />N� <br />= <br />V <br />w <br />r' a <br />wCO <br />mLO <br />O M <br />s� <br />J Q <br />J tn <br />F L4 <br />m <br />