Laserfiche WebLink
ENGINEER'S NOTES: <br />1, <br />DESIGN WIND SPEED: 140 <br />MPHult / 110 MPHasd , 3 sec gust <br />PER ATC HAZARDS BY <br />L❑CATI❑N <br />2, <br />RISK CATEGORY PER FBC <br />17 6TH EDITI❑N Table 1604,5 : II <br />3, <br />EXPOSURE CATEGORY = <br />"B" <br />4, <br />INTERNAL PRESSURE C❑EFFICIENT = <br />+/- 0.18 (ENCLOSED BLDG) <br />5, <br />COMPONENTS & CLADDING DESIGN PRESSURES PER ASCE 7-10: <br />FIGURE 30.5-1 <br />(ROOF) <br />ZONE 11o: <br />+10/-21 <br />psf <br />ZONE 2a; <br />+10/-37 <br />psf <br />ZONE Sal <br />+10/-55 <br />psf <br />(WALLS) <br />ZONE 4Io: <br />+21/-23 <br />psf <br />ZONE 510: <br />+21/-27 <br />psf <br />GENERAL NOTES <br />BUSINESS GROUP B 393 SQ FT/100 = 4 PEOPLE PER TABLE 100412 FBC <br />GROUP S LOW HAZARD 2007 SQ FT/500 = 4 PEOPLE PER TABLE 1004.1.2 FBC <br />3 SUITES @ 2400 = 7200 SQ FT <br />INTERIOR REQUIREMENTS <br />FLAME SPREAD/SMOKE DEV.—EXIT ACCESS UNSPRK1 TYPE 'B' FLAMESPREAD 26-75 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV,—EXIT ACCESS SPRK: TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES UNSPRK: TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450 <br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450 <br />X <br />W <br />TABLE 803,11 <br />INTERI❑R WALL AND CEILING FINISH REQUIREMENTS BY ❑CCUPANCYk <br />Z❑NING CLASSIFICATI❑N: <br />BUILDING AREA:7200 SQ,FT, TOTAL <br />BUILDING USE: BUSINESS <br />SPECIAL OCCUPANCY: N/A <br />GROUP: GROUP B <br />TYPE OF CONSTRUCTION: 3B <br />MIXED C❑NSTRUCTI❑M NO <br />BUILDING HEIGHT: <35" <br />SPRINKLED: NO <br />APPLICABLE BUILDING CODES <br />FLORIDA BUILDING CODE (FBC) Gth ed. BUILDING (2017) <br />FLORIDA BUILDING CODE (FBC) 6th ed. MECHANICAL (2017) <br />FLORIDA BUILDING CODE <FBC) 6th ed. ENERGY (2017) <br />FLORIDA BUILDING CODE (FBC) 6th ed. PLUMBING (2017) <br />FLORIDA FIRE PREVENTI❑N CODE Gth ed.(2017) <br />NATI❑NAL ELECTRICAL CODE, 2014 EDITI❑N <br />FLORIDA ACCESSIBILITY CODE 6th ed. (2017) <br />AMERICANS W/DISSABILITIES ACT (ADASAD), ed. (2010) <br />FIXTURES SHOWN MEET REQUIREMENTS <br />GROUP <br />SPRINKLERED <br />N❑NSPRINKLERED <br />Interior exit stairways and r <br />and exit passageways a, b <br />mpQorridors and <br />enclosure for exitenclosed <br />access stairways <br />and ramps <br />Rooms and <br />spaceg <br />Interior exit stairways <br />ramps and exit <br />passageways a, b <br />aBdr Idors and <br />encrosure for exit <br />access stairways <br />and ramps <br />Rooms and <br />enclosed <br />spaces c <br />A-1 & A-2 <br />B <br />B <br />C <br />A <br />A <br />B e <br />A-3f, A-4, A-5 <br />B <br />B <br />C <br />A <br />A <br />C <br />B E, M, R-1 <br />B <br />C <br />C <br />A <br />B <br />C <br />R-4 <br />B <br />C <br />C <br />A <br />B <br />B <br />F <br />C <br />C <br />C <br />B <br />C <br />C <br />H <br />B <br />B <br />C9 <br />A <br />A <br />B <br />I-1 <br />B <br />C <br />C <br />A <br />B <br />B <br />I-2 <br />B <br />B <br />B h.1 <br />A <br />A <br />B <br />I-3 <br />A <br />AJ <br />C <br />A <br />A <br />B <br />I-4 <br />B <br />B <br />Bh.1A <br />A <br />B <br />R-2 <br />C <br />C <br />C <br />B <br />B <br />C <br />R-3 <br />C <br />C <br />C <br />C <br />C <br />C <br />S <br />C <br />C <br />C <br />B <br />B <br />C <br />U <br />No restrictions <br />No restrictions <br />For SIB 1 Inch = 25.4 mm, 1 square foot = 0.0929 m2. <br />a.Class C Interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area In the grade <br />Lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and flreblocked as required by Section 803,13.1. <br />b.In other than Group I-3 occupancies In buildings less than three stories above grade plane, Class B Interior finish for nonsprinklered buildings and Class C <br />Interior finish for sprinklered buildings shall be permitted In Interior exit stairways and ramps, <br />c.Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating Is required for structural <br />elements, the enclosing partitions shalt extend from the floor to the tellingq Partitions that do not comply with this shall be considered enclosing spaces <br />and the rooms or spaces on both sides shall be considered one. In determini�ng the applicable requiremen-ts for rooms and enclosed spaces, the specific <br />occupancy thereof shall be the governing factor regardless of the group classification of the building or structure, <br />d.Lobby areas In Group A-1, A-2 and A-3 occupancies shalt not be less than Class B materials. <br />e.Class C Interior finish materials shall be permitted In places of assembly with an occupant load of 300 persons or less. <br />f.For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted. <br />g.Class B material is required where the building exceeds two stories. <br />h.Class C Interior finish materials shall be permitted In administrative spaces. <br />I.Class C Interior finish materials shalt be permitted In rooms with a capacity of four persons or less. <br />.Class B materials shall be permitted as wainscotting extending not more than 48 Inches above the finished floor In corridors and exit access stairways and ramps. <br />k.Flnlsh materials as rovided for In other sections of this code. <br />(.Applies when protected by an automatic sprinkler system Installed in accordance with Section 903.3.1.1 or 903.3.1.2. <br />INTERIOR FINISH SCHEDULE <br />INTERIOR FINISHES TO BE DETERMINED BY OWNER <br />RESTROOM FLOORS TO BE A NON ABORBENT MATERIAL <br />RESTROOM WALL TO BE A NON ABSORBENT MATERIAL <br />MINIMUM 4W A.F.F. <br />GENERAL NOiTES <br />k:" <br />- 0) i; r <br />�' .'�' � ill -NSF `< i�:�H,►� -i�: ti��)1 � �1 1R: r: liti�? F $�1111 ,* -1 0'1 ^� 10CJ'1�`�'�'F <br />u ir; <br />l\ ; I F DI 4 4F 1r, �'�� � * (' ' \ " F {"A QO-K 20�.y fii <br />'T I ��I,iti�� ( ;�jf��� ti�I� i�'1_i l�)�"!��ir., I� [�?I�( ;��i[•1F �i L�)?�)IT ��� iF(�T �;^J 1'' <br />r <br />ill Jut, ill F6 <br />I <br />1 <br />EXTE MOO F� WINDOWS & DOO OO F'� ASSEM =LIES: <br />FFF I*'s, •rI �'� .� h,;��� S �h,.I E ( F5 c�li; !N ;�C n��� �h(?F 'tiI�I�, N� 6�",1�+, �., �1),� <br />r�iDD =E'.".tiff <br />SAFE 1 YLAZING. <br />I hereloy certify that I have reviewed this plan and found it to loE in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W, Smith, P.E. # 3608 <br />ENGINEER LICENCE #53608 <br />e <br />INDEX S H T # <br />1, C❑VER <br />2, FLOOR PLAN <br />3, SIGHT PLAN <br />4, POWER PLAN <br />5, HVAC PLAN <br />6, FIRE SAFETY <br />7, UL SHEETS <br />All WM SHALL COMPLY WITH <br />NFFA CODES AND STANDARDS <br />ENDATE /I • f �� <br />Y OF ZEP147Y H, i.S <br />;-IRE MD LIFE SAFETY EXAMINER_,� <br />PLAN <br />>rlt►I W «pT: <br />CWT iw zapire j, <br />KAY.il (; <br />ALL WORK SHALL COMPLY WITH PREVAILING <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC' _:ODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />11 <br />PARCEL: 19- 26- 22- 0010- 00000- 0130 <br />CHANCEY PARTNERS <br />3773 CORREIA DR <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSI❑NAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE—DADE CITY, FLORIDA 33525 <br />PHONE: 813-469-2289 E-MAIL: dwsHp0earth l i nk. net <br />RICK GOLLHARDT - DRAFTSMAN <br />813- 781- 3651 <br />rgollhardt@tampabay.rr.com <br />COVER SHEET <br />SCALE <br />DO NOT SCALE <br />DESIGN/DRAWN <br />R. GOLLHARDT <br />DATE <br />9 OCT 2020 <br />CHECKED <br />D.W.S.,p.e. <br />SHEET OF <br />1 OF 7 <br />JOB NO. <br />V- <br />J <br />2020-1 Q03 <br />3773 �1 <br />