My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6327 Lot 13 Blk 14
Zephyrhills
>
Building Department
>
Building Plans
>
6327 Lot 13 Blk 14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:59:17 PM
Creation date
2/18/2025 3:26:25 PM
Metadata
Fields
Template:
Building Plans
Street #
6327
Location
Lot 13 Blk 14
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />_ _ <br />F <br />_ _ _ _ <br />i <br />; aoaoa000 ,/ <br />v v <br />El 1—:1E:1El D E] 11 <br />El <br />a <br />- <br />a � <br />INDEX <br />OF <br />DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />--_- <br />1.1 <br />FIRST FLOOR PLAN <br />1.2 <br />SECOND FLOOR PLAN <br />2.1 <br />EXTERIOR ELEVATIONS - FRONT & LEFT <br />2.2 <br />EXTERIOR ELEVATIONS - REAR & RIGHT <br />3 <br />ELECTRICAL PLAN <br />4 <br />ROOF PLAN <br />5 <br />FOUNDATION PLAN <br />6.1 <br />FLOOR FRAMING PLAN p <br />6.2 <br />ROOF FRAMING PLAN <br />7 <br />LINTEL PLAN & DETAILS U <br />SN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />-SN1 <br />DETAILS — <br />S3 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />ABV orAbv. Above <br />AC or A/C Air -Conditioner <br />ADJ or ADJ. Adjustable <br />AFF or A.F.F. Above Finished Floor <br />AHU orA.H.U. Air Handler Unit <br />ALT orALT. Alternate <br />BC Base Cabinet <br />BF Bifold Door <br />BK SH or Bk Sh BookShelf <br />BLK or BILK. Block <br />BLW or BLW. Below <br />BM or Bm. Beam <br />BOT or Bot. Bottom <br />BP or B.P. Bypass (door) <br />BRG or BRG. Bearing <br />C Carpet <br />CAB Cabinet <br />CIR or Cir. Circle <br />CJ or C/J Control Joint <br />CLG or Gig. Ceiling <br />CMU Concrete Masonry Unit <br />COFF or Coff. Coffered or Tray Ceiling <br />COL orCol. Column <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />CONN or CONN. Connection <br />CONTT or C.T.Cont. Continuous <br />CT or . Ceramic Tile <br />D or D. Dryer <br />DB Door Bell <br />DBL or Dbl. Double <br />DCF Decorative Cementitious Finish <br />DEC or Dec. Decorative <br />DED or Ded. Dedicated (outlet) <br />DIA or Dia. Diameter <br />DISP or Disp. Disposal <br />DIST or Dist. Distance <br />DMF Decorative Masonry Finish <br />DS or D.S. Drawer Stack <br />DTL Detail <br />DV or D.V. Dryer Vent <br />DVP or D.V.P. Diverter Valve (plumbing) <br />DWorD.W. Dishwasher <br />EA or Ea. Each <br />ELECorElec. Electrical <br />ELEVorElev. Elevation <br />EQ Equal <br />EWorE.W. Each Way <br />EXP or Exp. Expansion <br />EXT or Ext. Exterior <br />FBC Florida Building Code <br />FDN or Fdn. Foundation <br />FG Fiberglass (Shower Pan) <br />FIN Finished <br />FIN FLR or FF or Fin. Fir. Finished Floor <br />FIX or FXD Fixed <br />FLR or Fir. Floor <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />FR DR French Door <br />FRT Front <br />FT or Ft. Foot/ Feet <br />FTG or Ftg. Footing <br />FXD GL Fixed Glass <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />GFI or G.F.I. Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />HB Hose Bibb <br />HDR or Hdr. Header <br />HGTorHgt. Height <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />ILO In Lieu Of <br />Insul. Insulation <br />INT or Int. <br />INTorint. Interior <br />KJWALIL KlWall Knee Sp <br />KS. <br />KS or K.S. Knee Space <br />LAUN or Laun. Laundry <br />LF o L.F.Lavatory <br />LF or L. Linear Ft. <br />LL Lintel Length <br />LT Laundry Tub <br />MAS or Mas. Masonry <br />MAX or Max Maximum <br />MC Medicine Cabinet <br />MFR or Mfr. Manufacturer <br />MGT Management (room) <br />MIN or Min Minimum <br />MIR or Mir. Mirror <br />MIL or M.L. Microlam <br />MONO or Mono Monolithic <br />MW or MICRO or Micro. Microwave <br />NTS or N.T.S. Not to Scale <br />OE or O.E. Owner's Entry <br />OPNGorOpn'g. Opening <br />OPT or Opt. Optional <br />PC Pull Chain <br />PEDorPed. Pedestal <br />PH Phone <br />PKTorPkt. Pocket (Door) <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />PLT HT or Pit. Ht. Plate Height <br />PSF Pounds per square foot <br />PT or P.T. Pressure Treated <br />PW or P.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />RA or R/A or R.A. Return Air <br />RAD or Rad. Radius <br />RAG or Rag. Return Air Grill <br />REC or Rec. Recessed <br />RECEPT Receptacle <br />REF or Ref. Refrigerator <br />REINF Reinforcing <br />REQD or Req'd. Required <br />RM or Rm. Room <br />RND or Rnd. Round <br />RO or R.O. Rough Opening <br />RS, R/S, R/SH or R&S Rod and Shelf <br />SD or SD. Smoke Detector <br />SGD Sliding Glass Door <br />SH or Sh. Shelves <br />SHT Sheet <br />SHWRorShwr. Shower <br />SL or S.L. Side Lights <br />SPECS or SPECS. Specifications <br />SPF or S.P.F. Spruce Pine Fir <br />SQ FT or SF or S.F. Square Foot (feet) <br />SQ or Sq. Square <br />STO Storage <br />SW or S.Y.P.Shear Wall <br />SYP or S.YSouthern Yellow Pine <br />TB Towel Bar <br />TEMP or Temp. Tempered <br />THIKN or Thik'n. Thicken <br />TOB or T.O.B. Top of Block <br />TOM or T.O.M. Top of Masonry <br />TOP or T.O.P. Top of Plate <br />TP Toilet Paper Holder <br />TR Towel Ring <br />TRANS WDW or Trans. Transom Window <br />TYP or Typ. Typical <br />UC or u.c. Under Counter <br />UCL Under Cabinet Lighting <br />UNO or U.N.O. Unless Noted Otherwise <br />V or v. Valve (shower or tub/shower) <br />VB Vanity Base <br />VERT or Vert. Vertical <br />VL orV.L. Versalam <br />VTR orVTE Vent through Roof/Exterior <br />W or w Washer <br />W/orw/ With <br />WA or W.A. Wedge Anchor <br />WC or W/C or W.G. Water Closet (toilet) <br />WDorWd Wood <br />WDW HDR orWDW. HDR. Window Header <br />WH or W.H. Water Heater <br />WIC or W.I.C. Walk-in Closet <br />WM or W.M. Wall Mounted (plumbing fixture) <br />WP WaterProof(ing) <br />WS Water Softener <br />WWF Welded Wire Fabric (Mesh) <br />-- <br />S4 <br />---- — ---------- ---- <br />DETAILS <br />S5 <br />DETAILS <br />-- <br />SISM <br />DETAILS <br />--- <br />ST <br />---- <br />STAIR DETAILS <br />SS <br />^ <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />D2 <br />SECTIONS & DETAILS <br />Wp <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />— <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.2 <br />_ <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />— <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1,4 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />— <br />— — — <br />—J-- <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer /Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />immediately. No gner/Ebackchgineerrges w be <br />Office er dfo reimbursement <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />08/23/ 12 1.00 NEW BASE PLAN <br />. <br />IMP <br />07/30/ 15 1.1 2015 NEW CODE UPDATE <br />05/09/18 2.0 FBC 2017 CODE UPDATES <br />12/19/20 3.0 FBC 2020 CODE UPDATES <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />2074 <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be` -held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />a <br />J LL �- <br />w LU <br />T Ir <br />z <br />@ C <br />3: O <br />�� <br />oP w <br />LcoWc°n�pj6' <br />Z <br />O <br />N co <br />Qaa <br />J d <br />rr N O <br />Z <br />W <br />Z N P <br />0 0 <br />z <br />z o <br />Q <br />(OV) <br />N <br />M <br />z <br />C1 <br />v <br />0 <br />t` <br />a--+ V.)W E <br />fU <br />NE <br />0 (4 <br />�NU) <br />c g <br />U <br />W J <br />_ <br />U <br />x. <br />U ) N <br />Q N <br />I� <br />o <br />�w <br />M <br />2 <br />Z <br />za <br />U_ <br />zo <br />Zo <br />Qn <br />SZQ <br />cEa U <br />oWoM <br />® <br />Z <br />rO <br />R&Uz <br />UZ <br />a�a Z <br />� <br />wo <br />Qzp <br />M�N- <br />L <br />� <br />¢ <br />4 U <br />o <br />mi <br />Q <br />Z <br />Z <br />U) a� <br />J <br />a� <br />< w <br />N0 <br />Q <br />Q <br />U <br />N W <br />W <br />00 <br />a� <br />o <br />y <br />�� <br />10 <br />So <br />co <br /><t <br />zzl<TT° <br />a <br />3 <br />a <br />c Q <br />..tom <br />> M <br />J <br />0 <br />rn <br />m <br />m <br />Q� <br />c9 <br />L <br />C <br />T <br />: T <br />d- <br />Q <br />C Y <br />T <br />�h <br />v / <br />m <br />O <br />N <br />U-) <br />N <br />W <br />w <br />M <br />i N <br />i6 N <br />o <br />z <br />Z <br />E T <br />E <br />w <br />d <br />m <br />c <br />d <br />U � <br />Q p <br />JOB <br />NO: <br />22-02363 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S <br />
The URL can be used to link to this page
Your browser does not support the video tag.