Laserfiche WebLink
BUILDING INFORMATION <br />APPLICABLE CODES <br />ALL CONSTRUCTION SPECIFIED ON THESE DOCUMENTS SUBMITTED FOR <br />BUILDING PERMIT SHALL COMPLY WITH ALL CODES AND ORDINANCES <br />OF CITY OF ZEPHYRHILLS, FLORIDA. INCLUDING REVISIONS, <br />AMENDMENTS AND APPENDICES TO THE FOLLOWING CODES: <br />FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) <br />FLORIDA ACCESSIBLITY CODE 7TH EDITION (2020) <br />FLORIDA MECHANICAL CODE 7TH EDITION (2020) <br />FLORIDA PLUMBING CODE 7TH EDITION (2020) <br />FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) <br />FLORIDA ENERGY CONSERVATION CODE 7TH EDITION (2020) <br />ADDITIONAL APPLICABLE CODE <br />NFPA 101 LIFE SAFETY CODE FLORIDA EDITION <br />NATIONAL ELECTRIC CODE 2017 EDITION <br />FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) <br />OCCUPANCY CLASSIFICATION <br />FLORIDA BUILDING CODE, CHAPTER 3: <br />SECTION 304,1: BUSINESS GROUP B CLINIC, OUTPATIENT <br />BUSINESS GROUP B OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A <br />BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, <br />PROFESSIONAL OR SERVICE -TYPE TRANSACTIONS, INCLUDING STORAGE OF <br />RECORDS AND ACCOUNTS. <br />OCCUPANT USE- CLINIC, OUTPATIENT <br />Buildings or portions thereof used to provide medical care on less than a <br />24-hour basis to persons who are not rendered incapable of self- <br />preservation by the services provided FBC 202. <br />CONSTRUCTION CLASSIFICATION <br />FLORIDA BUILDING CODE, CHAPTER 6: <br />TYPE II-B CONSTRUCTION - EXISTING CONSTRUCTION PERMITTED <br />EXIST SHELL BUILDING INFO <br />BUILDING HEIGHT: 1 STORY <br />SPRINKLERED: NO <br />MEZZANINE: NO <br />FIRE DISTRICT: NO <br />e. <br />INTERIOR FINISHES <br />FLORIDA BUILDING CODE, CHAPTER 8: <br />BUSINESS - GROUP B (NON-SPRINKLERED) <br />INTERIOR WALL AND CEILING FINISHES REQUIREMENTS - TABLE 803.5 <br />EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B <br />ROOMS AND ENCLOSED SPACES: CLASS C <br />BUILDING / UNIT INFORMATION <br />TENANT S F. COMMON AREA S.F. TOTAL FLOOR S.F. <br />1ST FLOOR = 6,706 S.F. N/A N/A <br />ADDITIONAL PERMITS <br />ANY APPLICABLE PERMITS OR APPROVAL REQUIRED BY ANY OTHER <br />GOVERNMENT AGENCY (DEP, DOT, SWFWMD, COUNTY, ETC.) ARE THE <br />RESPONSABILITY OF THE APPLICANT TO OBTAIN. <br />SCOPE OF WORK <br />INTERIOR FIT -OUT OF NEW 1-STORY SHELL BUILDING (CONSTRUCTED UNDER <br />SEPARATE PERMIT) - 6,706 S.F. <br />Occupancy use is for Clinic, outpatient used to provide medical care on <br />less than a 24-hour basis to persons who are not rendered incapable of self <br />preservation by the services provided per FBC 202. <br />Spaces include exam rooms, waiting areas, physician offices, staff break <br />room, toilets, janitors closet, storage rooms. <br />TENANT REQUIREMENTS <br />EXIT REQUIREMENTS <br />NUMBER AND ARRANGEMENT OF EXITS: REFERENCE DRAWING A0.6 <br />FLOOR MIN NUMBER TRAVEL DISTANCE ARRANGEMENT <br />OF EXITS I MEANS OF EGRESS <br />REQUIRED SHOWN ALLOWABLE SHOWN REQUIRED SHOWN <br />TBL.1021.1 ON PLAN TBL.1016.1 ON PLAN BETWEEN ON PLAN <br />DOORS <br />TENANT <br />300' <br />55'-7" <br />CORRIDOR DEAD ENDS (SECTION 1017.3) <br />COMMON PATH OF TRAVEL (SECTION I014.3) <br />OCCUPANT LOAD ANnEIDTH <br />CALCULATED OCUPANT LOAD - <br />EXISTiNG BUSINESS BUILDING = 6,706 SF <br />BREAK ROOM: ASSEMBLY 358 SF / 15 NET=COMMUNITY: <br />394 SF / 15 NET = 27 PERSONWAITING: <br />179 SF / 15 NET= 12 PERSONS <br />COMM ROOM: 61 SF / 300 NET = 1 PERSOELEC. <br />ROOM/F. RISER: 101 SF / 300 NET= 1 <br />STORAGE 1: 33 SF / 300 NET= 1 PERSON <br />STORAGE 2: 86 SF / 300 NET = 1 PERSON <br />BIO: 12 SF / 300 NET = 1 PERSON <br />J.C.: 34 SF ( 300 NET = 1 PERSON <br />TOTAL OCCUPANCY = 106 PERSONS <br />PLUMBING FIXTURE REQUIREMENTS <br />OOR <br />MALE FEMALE <br />BUSINESS <br />REQUIRED <br />PROVIDED <br />REQUIRED <br />PROVIDED <br />106 PE ONS <br />TOILETS <br />2 <br />4 <br />2 <br />4 <br />LAVATORIES <br />2 <br />4 <br />2 <br />4 <br />SERVICE SINK 1 1 <br />DRINKING 1 1 <br />FOUNTAIN <br />NOTE: TOILETS EXISTING BUILDING PROVIDED NOT IN SCOPE OF WORK <br />FIXTURES REQUIRED / (FIXTURES PROVIDED) <br />LEGAL DESCRIPTION <br />PARCEL ID#: 35-25-21-0130-00000-0040 <br />ZEPHYR COMMONS PHASE 1 PB 65 PG 132 LOT 4 OR 9254 PG 1646 <br />SITE LOCATION <br />ARCHITECTURE / INTERIOR DESIGNER <br />CAMPBELL + VAN DUSEN DESIGN STUDIO <br />255 SOUTH ORANGE AVENUE <br />SUITE 1240 <br />ORLANDO, FLORIDA 32801 <br />407.930.6016 <br />CONTACT: FRANK W. CAMPBELL <br />CONTACT: GLORIA VAN DUSEN <br />ELECTRICAL ENGINEER <br />PENINSULA ENGINEERING, INC. <br />2016 ALDEN ROAD <br />ORLANDO, FLORIDA 32803 <br />407.246.1688 <br />CONTACT: BRYAN SPANGLER <br />ADVENT HEALTH <br />WELL 65+ ZEPHYRHILLS <br />MECH & PLUMB ENGINEER <br />PENINSULA ENGINEERING, INC. <br />2016 ALDEN ROAD <br />ORLANDO, FLORIDA 32803 <br />407.246.1688 <br />CONTACT: BRYAN SPANGLER <br />7866 GALL BOULEVARD, <br />ZEPHYRHILLS, FLORIDA 33541 <br />BUILDING OWNERS CONTRACTOR <br />ADVENTHEALTH TBD <br />900 HOPE WAY <br />ALTAMONTE SPRINGS, FLORIDA 32714 <br />407.963.1014 <br />CONTACT: DANIEL TOM <br />E1 , v iv, , `� l <br />1&f l }� <br />16 <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No, AR0016053 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AR0016053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />�I <br />LU <br />.J <br />Lr) <br />z <br />LL! <br />_ <br />LL <br />Q <br />� <br />LJ__f <br />N <br />J <br />H <br />J <br />rill <br />LU <br />N <br />n <br />r J� <br />IW <br />Q <br />00 (") <br />i� ('7 <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />PROJECT MANAGER <br />M. TORRES <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />COVER SHEET <br />