BUILDING INFORMATION <br />APPLICABLE CODES <br />ALL CONSTRUCTION SPECIFIED ON THESE DOCUMENTS SUBMITTED FOR <br />BUILDING PERMIT SHALL COMPLY WITH ALL CODES AND ORDINANCES <br />OF CITY OF ZEPHYRHILLS, FLORIDA. INCLUDING REVISIONS, <br />AMENDMENTS AND APPENDICES TO THE FOLLOWING CODES: <br />FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) <br />FLORIDA ACCESSIBLITY CODE 7TH EDITION (2020) <br />FLORIDA MECHANICAL CODE 7TH EDITION (2020) <br />FLORIDA PLUMBING CODE 7TH EDITION (2020) <br />FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) <br />FLORIDA ENERGY CONSERVATION CODE 7TH EDITION (2020) <br />ADDITIONAL APPLICABLE CODE <br />NFPA 101 LIFE SAFETY CODE FLORIDA EDITION <br />NATIONAL ELECTRIC CODE 2017 EDITION <br />FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) <br />OCCUPANCY CLASSIFICATION <br />FLORIDA BUILDING CODE, CHAPTER 3: <br />SECTION 304.1: BUSINESS GROUP B CLINIC, OUTPATIENT <br />BUSINESS GROUP B OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A <br />BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, <br />PROFESSIONAL OR SERVICE -TYPE TRANSACTIONS, INCLUDING STORAGE OF <br />RECORDS AND ACCOUNTS. <br />OCCUPANT USE- CLINIC, OUTPATIENT <br />Buildings or portions thereof used to provide medical care on less than a <br />24-hour basis to persons who are not rendered incapable of self- <br />preservation by the services provided FBC 202. <br />CONSTRUCTION CLASSIFICATION <br />FLORIDA BUILDING CODE, CHAPTER 6: <br />TYPE II-B CONSTRUCTION - EXISTING CONSTRUCTION PERMITTED <br />EXIST SHELL BUILDING INFO <br />BUILDING HEIGHT: I STORY <br />SPRINKLERED: NO <br />MEZZANINE: NO <br />FIRE DISTRICT: NO <br />INTERIOR FINISHES <br />FLORIDA BUILDING CODE, CHAPTER 8: <br />BUSINESS - GROUP B (NON-SPRINKLERED) <br />INTERIOR WALL AND CEILING FINISHES REQUIREMENTS - TABLE 803.5 <br />EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B <br />ROOMS AND ENCLOSED SPACES: CLASS C <br />BUILDING / UNIT INFORMATION <br />TENANT S.F. COMMON AREA S.F. TOTAL FLOOR S.F. <br />1ST FLOOR = 6,706 S.F. N/A N/A <br />ADDITIONAL PERMITS <br />ANY APPLICABLE PERMITS OR APPROVAL REQUIRED BY ANY OTHER <br />GOVERNMENT AGENCY (DEP, DOT, SWFWMD, COUNTY, ETC.) ARE THE <br />RESPONSABILITY OF THE APPLICANT TO OBTAIN. <br />SCOPE OF WORK <br />INTERIOR FIT -OUT OF NEW 1-STORY SHELL BUILDING (CONSTRUCTED UNDER <br />SEPARATE PERMIT) - 6,706 S.F. <br />Occupancy use is for Clinic, outpatient used to provide medical care on <br />less than a 24-hour basis to persons who are not rendered incapable of self- <br />preservation by the services provided per FBC 202. <br />Spaces include exam rooms, waiting areas, physician offices, staff break <br />room, toilets, janitors closet, storage rooms. <br />TENANT REQUIREMENTS <br />EXIT REQUIREMENTS <br />NUMBER AND ARRANGEMENT OF EXITS: REFERENCE DRAWING A0.6 <br />FLOOR MIN NUMBER TRAVEL DISTANCE ARRANGEMENT <br />OF EXITS MEANS OF EGRESS <br />REQUIRED SHOWN ALLOWABLE SHOWN REQUIRED SHOWN <br />TBL.1021.1 ON PLAN TBL.1016.1 ON PLAN BETWEEN ON PLAN <br />DOORS <br />TENANT <br />300' <br />55'-9" <br />CORRIDOR DEAD ENDS (SECTION 1017.3) <br />COMMON PATH OF TRAVEL (SECTION 1014.3) <br />OCCUPANT LOAD AND EXIT WIDTH <br />CALCULATED OCUPANT LOAD - <br />EXISTING BUSINESS BUILDING = 6,706 SF <br />BREAK ROOM: ASSEMBLY 387 SF / 15 NET = 26 PERSONS <br />COMMUNITY: 394 SF / 15 NET = 27 PERSONS <br />WAITING: 179 SF / 15 NET = 12 PERSONS <br />COMM ROOM: 61 SF / 300 NET = 1 PERSON <br />ELEC. ROOM/F. RISER: 101 SF / 300 NET = 1 PERSON <br />STORAGE l: 33 SF / 300 NET = I PERSON <br />STORAGE 2: 86 SF / 300 NET = I PERSON <br />BIO: 12 SF / 300 NET = 1 PERSON <br />J.C.: 34 SF / 300 NET = 1 PERSON <br />TOTAL OCCUPANCY = 108 PERSONS <br />PLUMBING FIXTURE REQUIREMENTS <br />FLOO <br />MALE FEMALE <br />BUSINESS <br />REQUIRED <br />PROVIDED <br />REQUIRED <br />PROVIDED <br />108 PERSONS <br />TOILETS <br />2 <br />4 <br />2 <br />4 <br />LAVATORIES <br />2 <br />4 <br />2 <br />4 <br />SERVICE SINK 1 1 <br />DRINKING 1 I <br />FOUNTAIN <br />NOTE: TOILETS EXISTING BUILDING PROVIDED NOT IN SCOPE OF WORK <br />FIXTURES REQUIRED / (FIXTURES PROVIDED) <br />LEGAL DESCRIPTION <br />PARCEL ID#: 35-25-21-0130-00000-0040 <br />ZEPHYR COMMONS PHASE 1 PB 65 PG 132 LOT 4 OR 9254 PG 1646 <br />O nion Ave <br />.i,-Wa-d Ran , <br />r nFie u. C i T 1 t ( <br />r �•,.��. 1 t j't s <br />Y i ti a <br />Pasadena Hlls <br />ARCHITECTURE / INTERIOR DESIGNER <br />CAMPBELL + VAN DUSEN DESIGN STUDIO <br />255 SOUTH ORANGE AVENUE <br />SUITE 1240 <br />ORLANDO, FLORIDA 32801 <br />407.930.6016 <br />CONTACT: FRANK W. CAMPBELL <br />CONTACT: GLORIA VAN DUSEN <br />Citrus Hill RV ResortMan.. <br />r <br />Mansions,; <br />V Resorl <br />Richland <br />7874 Gall Blvd, <br />1 -'r ilia"•"k,�i I m' "I '.v;s`e Ffeiah! a Rd Zephyr ills, FL 3354-1 <br />- 7ERHYRHILL r_ M, <br />rt.6y <br />COLONY <br />O L O N <br />o-: • <br />1 4-�����. t ;,� o;I ' I cw ,'__� I �.. a-� .: COMPANY �� � I , t <br />c ie'A <br />O <br />North <br />4i <br />%l.4Jl it) d,,v e : <br />CD <br />r'• lad <br />SITE LOCATION <br />ELECTRICAL ENGINEER <br />PENINSULA ENGINEERING, INC <br />2016 ALDEN ROAD <br />ORLANDO, FLORIDA 32803 <br />407.246.1688 <br />CONTACT: BRYAN SPANGLER <br />ADVENT HEALTH <br />WELL 65+ ZEPHYRHILLS <br />MECH & PLUMB ENGINEER <br />PENINSULA ENGINEERING, INC. <br />2016 ALDEN ROAD <br />ORLANDO, FLORIDA 32803 <br />407.246.1688 <br />CONTACT: BRYAN SPANGLER <br />hbl� <br />7866 GALL BOULEVARD, <br />ZEPHYRHILLS, FLORIDA 33541 <br />REVIEW DATE: <br />CITY OF ZEPHYRHILL <br />BUILDING OFFICIAL <br />BUILDING OWNERS <br />ADVENTHEALTH <br />900 HOPE WAY <br />ALTAMONTE SPRINGS, FLORIDA 32714 <br />407.963.1014 <br />CONTACT: DANIEL TOM <br />0 <br />CONTRACTOR <br />TBD <br />CAMPBELL + VAN DUSE <br />ARCHITECTURE INTERIOR DES <br />WWW.CVDStUdIO.COr <br />CAMPBELL + VAN DUSEN Design Studio <br />255 South Orange Avenue Suite #1' <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AR0016053 <br />r— <br />77 <br />t <br />T <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AR0016053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />MI v� <br />or'k4di . <br />J <br />Z ry <br />0 _ <br />n <br />LU <br />_I <br />L11 LLJ —I I <br />m <br />I-- F-- j = <br />U Z .o Q <br />0 0 LU LU <br />>> �o �n <br />a-Q > IV Ill <br />(n <br />ISSUE FOR <br />CONSTRUCTION DOCUMENTS <br />ISSUE DATE <br />03.24.2023 <br />REVISIONS <br />NO. DATE I DESCRIPTION <br />1 08/04/2023 REVISION I <br />B 05/03/2023 1ADDENDUM B <br />PROJECT TEAM <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />. ............ <br />PROJECT MANAGER <br />M. TORRES <br />CLIENT NAME <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />PROJECT NUMBER <br />22-0328-01 <br />SHEET TITLE <br />COVER SHEET <br />SHEET NUMBER <br />A0.0 <br />