RENOVATIONS FOR NEW LOCATION <br />MEALS ON WHEELS PASCO COUNTRY <br />GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNEC TO CONFORM TO THE 2017 FLORIDA BUILDING CODE <br />6TH EDITION <br />T L HANSON & ASSCCIA.TES INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL <br />ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOOR: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD - 20 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2017 FLORIDA <br />BUILDING CODE 6TH ADDITION SECTION 1609 <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT & EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/_ 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />SOIL BEARING & COMPACTION <br />COMPONENT & CLADDING WIND LOADS <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.7 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />5 <br />N/A <br />+35.31-47.2 <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIE I°LE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />T L HANSON & ASSOCIATES INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL <br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING F..-,!S RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE i REATMv ::NT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />BUILDING DATA: <br />USE AND OCCUPANCY: MIXED <br />BUSINESS GROUP B 4117 SQ. FT. <br />ASSEMBLEY A-2 FUTURE 2169 SQ. FT. <br />TOTAL AREA <br />6286 SQ. FT. <br />NO ADDITIONAL AREA ADDED TO BUILDING <br />INTERIOR RENOVATIONS ONLY <br />TYPE CONSTRUCTION: VB <br />FIRE PROTECTION: NON SPRINKLED <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />ABOVE DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING & COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, -FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />PLUMBING PEF2017 FLORIDA BUILDING CODE <br />PLUMBING 6TH EDITION CHAPTER 4, TABLE 403.1. <br />_- D E S I G N S I N C <br />BUILDING DESIGNS <br />13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523 <br />OFFICE 352-523-2077 FAX 352-567-2070 <br />38120 15TH AVE <br />ZEPHYRHILLS, FLORIDA <br />SITE LOCATION MAP JOB SITE <br />6TH EDITION FLORIDA FIRE PREVENTION <br />6TH EDITION 2017 FLORIDA BUILDING CODE <br />6TH EDITION 2017 FLORIDA ACCESSIBILITY CODE <br />6TH EDITION 2017 FLORIDA ENERGY CONSERVATION CODE <br />6TH EDITION 2017 FLORIDA MECHANICAL CODE <br />6TH EDITION 2017 FLORIDA PLUMBING CODE <br />2017 NFPA 10 (STANDARD FOR PORTABLE FIRE EXTINGUISHERS) <br />2014 NATIONAL ELECTRICAL CODE (NFPA 70) <br />CONTRACTOR TO PROVIDE TACTICAL SIGNS AS PER NFPA 1:14.14.1.3 <br />CONTRACTOR TO PROVIDE SIGNS DESIGNATING TYPE OF <br />ROOF CONSTRUCTION PER FAC 69A-3/012 (6) <br />BUILDING HAS WOOD ROOF SYSTEM <br />LIGHT FRAME CONSTRUCTION SIGN REQUIRED <br />CONTRACTOR TO PROVIDE UL 1037 APPROVED ACCESS BOX PER NFPA 1:18.2.2.1 <br />RESTROOM FLOORS TO BE A NON ABSORBENT MATERIAL <br />RESTROOM WALLS TO BE A NON ABSORBENT MATERIAL <br />MINIMUM 60" ABOVE FINISH FLOOR <br />INTERIOR FINISHES <br />TABLE 803.11 <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY" <br />SPRINKLERED' <br />NONSPRINKLERED <br />GROUP <br />Inferior exit stairways and ramps. <br />and exit passageways" ° <br />Corridors and <br />enclosure for exit <br />access stairways <br />and ramps <br />Rooms and <br />i enclosed <br />I spaces` <br />Interior exit stairways and <br />rampsand eways, o <br />passageways' <br />Corridors and <br />enclosure for exit <br />access s mrp'says <br />and ram s <br />Rooms and <br />enclosed <br />spaces` <br />A-1 & A-2 <br />B <br />---Cq <br />B <br />C <br />A <br />Ad <br />B° <br />A-Y, A-4, A-> <br />.a <br />B, H. NI, R-I <br />B <br />C <br />C <br />A <br />B <br />C <br />F <br />C <br />C <br />C <br />B <br />C <br />C <br />H <br />B <br />B <br />Cr <br />A <br />A <br />B <br />I -I <br />B <br />C <br />C <br />A <br />B <br />B <br />I--2 <br />B <br />B <br />B"' <br />I A <br />A <br />B <br />I-3 <br />A <br />Al <br />C <br />A <br />A <br />B <br />I-4 <br />B <br />B <br />B" ' <br />A <br />A <br />B <br />I <br />R-2 <br />C: <br />C <br />C <br />B <br />B <br />C <br />R-� <br />C <br />C <br />C <br />C <br />C <br />C <br />s <br />C <br />C <br />C <br />B <br />B <br />C <br />IJ <br />No restrictions <br />No restrictions j <br />For SI: 1 inch = 25.4 mm, 1 square foot = 0.0929m-. <br />a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby <br />where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section 803.13:1. <br />b. In other than Group 1-3 occupancies in buildings less that. three stories above made plane, Class B interior finish for nonsprinldered buildings and Class C <br />interior finish for sprindlered bulldings.shall be permitted in interior exit stairways and ramps. <br />c. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions_ Where afire -resistance rating is required for structural <br />elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the <br />rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed space,, the specific occupancy <br />thereof shall be the governing factor regardless of the group classification of the building or structure. <br />d. Lobby areas in Group A-1. A-2 and A-3 occupancies shall not be less than Class B materials. <br />e_ Clatis C interior finish materials shall be permitted in places ofassembly with an occupant load of 300 persons or less. <br />f. For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted. <br />g. Class B matc <br />h. Class C inter <br />i. Chrss C inter <br />; Class B naau to finished floor in corridors and exit access stairways and <br />tamps. <br />k. Finish mater <br />L. Applies he .3.1.1 or 903.3.1.2. <br />RYMAN CONSTRUCTION INC <br />36413 STR RD 54 <br />ZEPHYRHILLS, FL 33541 <br />OFFICE 813-782-0825 <br />PLAN INDEX: <br />SHEET B 1 : EXISTING BUILDING FLOOR PLAN <br />SHEET B 2: DEMOLITION BUILDING FLOOR PLAN <br />SHEET B 3: PROPOSED BUILDING FLOOR PLAN <br />DOOR SCHEDULE <br />CUT DOOR OPENING DETAIL <br />INTERIOR WOOD WALL DETAIL <br />WOOD FIRE WALL DETAIL <br />SHEET E1 : EXISTING ELECTRICAL DRAWINGS <br />SHEET E2 : PROPOSED ELECTRICAL DRAWINGS <br />SHEET M1 : MECHANICAL DRAWINGS <br />SHEET P1 : PLUMBING DRAWINGS <br />�% 41k <br />�'4a �;,3gQes3arAas&®���t4 A��g <br />ftz <br />Vol <br />s <br />per., ii $� <br />T <br />(352) 521-5540 <br />T. L. H,4N&ON <br />4 ,4550CIATES/ INC;, <br />CO141SULTING ENGINEERS <br />EN&INEERING; 5U6INE88 NO. E55030 <br />Post Office Box 1-728 <br />Dade City, Florida 33526 <br />THOMA5 L. HAN50N, PE 35654 <br />