Laserfiche WebLink
L <br />i I I- l' I' I -j- 1' 1+111! u 'I'i III--1- <br />ENGINEER'S NOTES: <br />1, DESIGN WIND SPEED; 140 MPHult / 110 MPHasd , 3 sec gust <br />PER ATC HAZARDS BY L❑CATI❑N <br />2, RISK CATEGORY PER FBC 2020 7TH EDITI❑N Table 1604,5 1 II <br />3. EXPOSURE CATEGORY = 'B' <br />4, INTERNAL PRESSURE C❑EFFICIENT = +/- 0.18 (ENCLOSED BLDG) <br />5, COMPONENTS & CLADDING DESIGN PRESSURES PER ASCE 7-16; <br />FIGURE 30,4-1 WITH LAMDA FACTOR = 0.82 <br />HIP ROOF <br />ROOF ZONE 1 (20)SF; +12/-21 psf <br />ROOF ZONE 2e (10)SF: +13/-32 psf <br />ROOF ZONE 2r (10)SF; +13/-32 psf <br />ROOF ZONE 3 (10)SFi +13/-32 psf <br />WALL ZONE 4 (20)SF; +18/-20 psf <br />WALL ZONE 5 (20)SF: +18/-24 psf <br />6, ROOF LIVE LOAD: 20 psf <br />ROOF DEAL L❑ADi 15 psf <br />GENERAL NOTES <br />C❑NSTRUCTI❑N TYPE: 5-B <br />ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />ACI 530-16, ASCE 5/TMS 402-16 & ACI 530,1-13, ASCE 6/TMS 602-16 <br />SPECIFICATIONS FOR MASONRY STRUCTURES, <br />ASTM C270-12a, C90-0610 & C91-05 SPECIFICATI❑NS FOR MASONRY STRUCTURES <br />NATI❑NAL DESIGN SPECIFICATI❑NS (NDS) FOR WOOD C❑NSTRUCTION, 2015 EDITI❑N, AND ALL <br />ACCOMPANYING SUPPLEMENTS, ASCE 7-16 <br />FLORIDA RESIDENTIAL CODE (FBC-R), FLORIDA BUILDING CODE (FBC) 7th ed, (2020) <br />"MANUAL OF STEEL C❑NSTRUCTI❑N, ALLOWABLE STRESS DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL C❑NSTRUCTI❑N, (AISC) 13TH EDITION, <br />"DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />TRUSS PLATE INSTITUTE TRI1-14, <br />DESIGN <br />ACI 301-16 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />ACI 530-16, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 <br />SPECIFICATI❑NS FOR MASONRY STRUCTURES, <br />ASTM C270-12a, C90-0610 & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES <br />NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD C❑NSTRUCTI❑N, 2015 EDITION, <br />AND ALL ACC❑MPANYING SUPPLEMENTS, <br />PLYWOOD DESIGN SPECIFICATIONS (APA) <br />FLORIDA BUILDING CODE (FBC) 7th ed, (2020) AND <br />FLORIDA BUILDING CODE 7th ed, RESIDENTIAL (FBCR) <br />ASCE 7-16 <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARI❑US <br />CONNECTED COMPONENTS, PR❑VIDE ADEQUATE BRACING, SH❑RING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE WORK, <br />ALL WINDOWS AND DOORS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS <br />TO RESIST THE WIND LOADS INDICATED AND TO MEET OTHER CODE REQUIREMENTS FOR <br />AIR AND WATER INTRUSION, FOR BUILD-UP DOORS) WINDOWS OR ACCESSORIES <br />PERMANENTLY ATTACHED THROUGH THE BODY OF THE MATERIAL BEING FASTENED USE <br />#10 WOOD SCREWS PENETRATING INTO THE ROUGH FRAMING MENBER AT LEAST 2" @ 12" <br />ON CENTER, OR MASONRY ATTACHMENTS USE 3/16" X 1" EMBEDMENT "TITAN" OR "TAPC❑N" <br />HEX HEAD MASONRY ANCHORS @ 12" ON CENTER, <br />WINDOW AND DOOR MANUFACTURERS TO PR❑VIDE CERTIFICATION/RATING THAT THEIR WINDOWS AND DOORS <br />WILL WITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING WIND <br />PRESSURE AND PR❑VIDE INSTALLATION INFORMATION WITH THEIR PRODUCTS. <br />CONTRACTOR TO INSTALL WINDOWS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEW BY THE <br />BUILDING INSPECTOR, <br />ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED <br />PR❑VIDE TEMPERED GLAZING IN ACCORDANCE WITH FBC FOR GLAZED, SLIDING, FIXED AND <br />SWING DOORS, ALSO SHOWER ENCLOSURES AND ALL GLAZING WITH 24" OF ALL DOORS, ALL <br />GLAZING 9.0 SQ FT OR GREATER, OR LESS THAN 18" A,F,F, SHALL BE TEMPERED, (FBC R308,4) <br />ALL EGRESS WINDOWS FROM SLEEPING ROOMS SHALL HAVE A MINIMUM CLEAR ❑PENING <br />OF 5.7 SQ, FT, (MIN ❑PENING SIZES = 2'-0" X 1'-8 SILL @ 44" A.F,F, MAX) <br />GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND COORDINATING ALL FIELD DIMENSIONS, <br />CONTRACTOR IS TO VERIFY ANY STRUCTURAL <br />OR CODE REQUIREMENTS PRIOR TO C❑NSTRUCTI❑N, AND TO BUILD ACCORDINGLY, <br />CONTRACTOR TO VERIFY DIMENSIONING PRIOR TO C❑NSTRUCTI❑N AND TO <br />NOTIFY OWNER & ENGINEER FOR ANY DIMENTI❑NAL CORRECTIONS PRIOR <br />TO C❑NSTRUCTI❑N, <br />NOTE: <br />R314,2,2 ALTERATIONS, REPAIRS AND ADDITIONS, WHEN ALTERATIONS, REPAIRS OR ADDITIONS <br />REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN <br />EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED <br />AS REQUIRED FOR NEW DWELLINGS, <br />CONTRACTOR TO INSPECT AND INSURE THAT EXISTING HOUSE HAS SMOKE & CO DETECTORS AT EACH BEDROOM AND <br />AND OUTSIDE BEDROOMS WITHIN 10 FEET OF SLEEPING AREAS TO BE IN COMPLIANCE <br />N = -7 = 1 <br />STRUCTURAL_ DESIGN REQUIRES <br />ALL DOORS AND WINDOWS TO BE FLORIDA APPROVED AND <br />RATED FOR INDICATED DESIGN PRESSURES AND <br />SPECIFIC BRANDS TO BE DETERMINED <br />BY ❑WNER AND C❑NTRACT❑R <br />NOTE: DOOR AND WINDOW MANUFACTURER TO PROVIDE RATING <br />CERTIFICATION FOR THEIR PRODUCTS INDICATING <br />DOORS WILL WITHSTAND THE PRESSURES <br />RESULTING FROM INDICATED WIND SPEED (3 SEC GUST) <br />NOTE: DOOR AND WINDOW MANUFACTURER TO PROVIDE <br />INSTALLATION INSTRUCTIONS FOR THEIR PRODUCT <br />SUCH THAT WHEN INSTALLED PER THEIR <br />INSTRUCTIONS THE RATED PERFORMANCE WILL <br />BE ATTAINED, <br />cu <br />EXISTING STRUCTURE <br />FLOOR PLAN <br />E EXIST <br />PEN ING <br />19m., <br />3-01 1 1­-7,-2„ <br />5' BF <br />BEDROOM <br />v- <br />V-5 <br />EXISTING <br />ATTIC <br />ACCESS <br />M <br />0 <br />STORAGE <br />EX <br />----------------- <br />22.�I <br />FRONT ELEVATION <br />SCOPE OF WORKS REMOVE EXISTING GARAGE DOOR C\ <br />ADD NEW BEDROOM AND STORAGE AREA J' <br />FILL IN GARAGE DOER AREA AND ADD NEW , <br />EGRESS WINDOW WITH 5' FRENCH DOOR _ <br />AREA'S <br />LIVING <br />STORAGE <br />TOTAL AREA <br />EXISTING <br />PANEL <br />C <br />� I <br />7R iN� F cir FO�TRIc G141c r✓�1I y pR <br />�Es ��pc � 6� , t/Ak/Nc <br />s <br />200 <br />284 <br />484 S.F. <br />PARCEL: 15— 26— 21— 0160— 00000— 0400 <br />D.W.SMITH,M.S.,P.E.#53608 BOWMAN PATRICIA <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 4 616 WISTERIA DR <br />PROJECTS ENGINEERING CONSULTANT ZEPHYRHILLS, FLORIDA <br />P909 C13 0N89 I VE—DAD CITY, tatHONN:(ELL)84692E-MAL: wsfflp@earhnkn ELEVATIONS SHEET OF <br />FLOOR PLAN 1 OF 4 <br />SCALE DATE JOB NO, <br />DO NOT SCALE 1 JUN 2023 <br />2023-0514 <br />DESIGN/DRAWN CHECKED <br />. rr, core R. GOLLHARDT D.W.S.PE <br />NOTE: CONTRACTOR TO INSTALL DOORS AND WINDOWS ACCORDING <br />TO MANUFACTURER'S INSTRUCTIONS, <br />I hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W, Smith, P,E, #53608 <br />RICK COLLHARDT — DRAFTSMAN <br />PHOND (CELU 813-781-3651 E-MAILI rgollhardt@tarp <br />