<br />ENGINEER'S NOTES
<br />ALL WORK TO BE DONE ACC❑RDING TO FLORIDA BUILDING CODES.
<br />BUILDINGS OR STRUCTURES SHALL CONFORM TO
<br />2017 FBC 6TH, EDITI❑N BUILDING,
<br />AN ADDITI❑N TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS
<br />FOR NEW C❑NSTRUCTI❑N WITH❑UT REQUIRING THE EXISTING BUILDING OR STRUCTURE
<br />TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PR❑VISI❑NS
<br />EXCEPT AS REQUIRED BY CHAPTER 10, WHERE AN ADDITI❑N IMPACTS THE EXISTING
<br />BUILDING OR STRUCTURE, THAT P❑RTI❑N SHALL COMPLY WITH THIS CODE,
<br />CREATI❑N OR EXTENSI❑N OF N❑NC❑NF❑RMITY. AN ADDITI❑N SHALL NOT CREATE OR
<br />EXTEND ANY N❑NC❑NF❑RMITY IN THE EXISTING BUILDING TO WHICH THE ADDITI❑N IS
<br />BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY,
<br />MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL
<br />SYSTEMS,
<br />ASSUMED S❑IL BEARING CAPACITY TO BE 2000 PSF, S❑IL CAPACITY TO BE VERIFIED
<br />BY CONTRACTOR PRI❑R TO C❑NSTRUCTI❑N. INF❑RM ENGINEER OF VARIATI❑NS.
<br />F❑❑TINGS TO BE EXCAVATED TO CLEAN S❑IL, FREE OF VEGETATI❑N AND
<br />DELETERI❑US MATTER, CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE,
<br />CONCRETE ;
<br />MINIMUM C❑MPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS, ALL
<br />CONCRETE SHALL BE "READY MIXED' AND IN ACCORDANCE WITH A,S.T,M,
<br />SPECIFICATI❑N C-94,
<br />SLAB ON FILL
<br />INTERI❑R CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF
<br />MEMBRANES. ALL SLABS TO BE REINF❑RCED WITH 6XG 10/10 WELDED WIRE MESH,
<br />LUMBER ;
<br />1, STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED,
<br />2, CURRENT EDITI❑N, ASS❑CIATI❑N GRADING RULES GOVERN.
<br />3, ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY,
<br />4, ANY SPECIES ALLOWED UNLESS ❑THERWISE NOTED,
<br />5. SIZES ARE N❑MINAL. ACTUAL SIZES SHALL CONFORM TO AMERICAN
<br />LUMBER STANDARD PS 20-70.
<br />6, M❑ISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE
<br />19% OR LESS AT THE TIME OF INSTALLATI❑N.
<br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO
<br />AMERICAN INSTITUTE OF TIMBER C❑NSTRUCTI❑N (AITC) SPECIFICATI❑NS, ALL
<br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED.
<br />TERMITE TREATING 1
<br />S❑IL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0'
<br />BEYOND THE PERIMETER LINES OF THE BUILDING,
<br />ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3" AGAINST
<br />S❑IL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR.
<br />HEADERS SHALL BE DBL, 2X MEMBERS AND LAMINATED W/1/2" PLYWOOD
<br />GLUED W/C❑NSTRUCTI❑N ADHESIVE AND NAILED W/#16D COMMONS 16' D.C.
<br />ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS.
<br />CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATI❑NS (CUT SHEETS) ON SITE
<br />AT THE TIME OF INSPECTI❑N, FOR REVIEW BY THE BUILDING INSPECT❑R,
<br />TO MEET LOADS AS INDICATED,
<br />DOORS & WIND❑WS
<br />ENGINEERS NOTES:
<br />DESIGN LOADS,
<br />A. WIND LOADS, PER+
<br />1) RISK CATEGORY IL - PER (TABLE 1604,5/TABLE 1.5-1)
<br />2) EXP. "B', PER TABLE 1609,4,5/SECTI❑N 26,7.5
<br />3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 140 MPH ult 3 SEC GUST V/
<br />4) N❑MINAL DESIGN WIND SPEED, V (ASD) = 110 MPH asd 3 SEC GUST
<br />5) INTERNAL PRESSURE C❑OFFICIENT, GCPI = .18 ENCL❑SED PER TABLE 26,11,1
<br />6) COMP. & CLADDING PRESSURES PER TABLE R301,2(2), UNLESS SPECIFICALLY LABELED ON PLAN
<br />B. LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED T01
<br />1) ROOF LIVE LOAD = 20 PSF
<br />2) FLOOR LIVE LOAD = 40 PSF
<br />3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF
<br />4) HABITTABLE ATTIC LIVE LOAD = 20 PSF
<br />C. DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED T❑i
<br />1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF
<br />2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF
<br />3) FLOOR DEAD LOAD = 20 PSF
<br />APPLICABLE CODES:
<br />6TH. EDITI❑N, 2017 FLORIDA BUILDING CODE, BUILDING, PLUMBING,
<br />MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING
<br />6TH. EDITI❑N, 2017 FLORIDA FIRE PREVENTI❑N CODE (IF APPLICABLE)
<br />2014 NATI❑NAL ELECTRICAL CODE
<br />DATA SUMMARY:
<br />BUILDING USE1 SINGLE FAMILY RESIDENCE TYPE R1,
<br />C❑NSTRUCTI❑N TYPE V, UNPROTECTED, UNSPRINKLED
<br />ALL BEDROOMS REQUIRE AN ❑UTSIDE WIND❑W OR DOOR OPERABLE FROM INSIDE WITH❑UT THE
<br />USE OF TOOLS AND PR❑VIDING A CLEAR ❑PENING OF NOT LESS THAN 20' WIDTH, 24' IN HEIGHT
<br />& 5,7 SQ. FT. IN AREA, THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" OFF THE
<br />FLOOR AND NO PART OF THE ❑PERATING MECHANISM SHALL BE PLACED HIGHER THAN 54" A.F,F,
<br />WIND❑WS GREATER THAN 72" ABOVE 72' FINISHED GRADE SHALL HAVE THW WIND❑W SILL HEIGHT
<br />GREATER THAN 24' OR PR❑VIDE AN FALL PREVENTIVE DEVICE PER R6162,
<br />DOORS & WIND❑WS
<br />THE ❑PERATIJ�G MECHANISM FOR SINGLE HUNG WIND❑WS SHALL BE AT OR NEAR THE SILL.
<br />WIND❑WS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM TO THE BLDG,
<br />CODE W/ RESPECT TO MIN. EMERGENCY EGRESS REQUIREMENTS PER N,F,P,A, 101 CHAPTER 24,
<br />ALL GLASS WITHIN 24' OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND
<br />SHOWER ENCLOSURES AND WIND❑WS WITHIN LESS THAN 60' AV❑VE STAIR LANDINGS OR TREADS SHALL BE
<br />TEMPERED SAFETY GLASS, SEE ADDITI❑NAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308,
<br />SINGLE SWING EXTERI❑R DOORS C❑NNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH
<br />S❑LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, S❑LID OR HONEYCOMB CORE
<br />STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED DOORS.
<br />WHERE MASONRY ❑PENINGS REQUIRE WOOD FRAMING, TO FIT WIND❑W OR DOOR SIZES, PRESSURE
<br />TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA, x 3 1/2' TAPC❑N SCREWS, 6"
<br />FROM EACH END AND 12' C/C, ADDITI❑NAL FRAMING MEMBERS SHALL BE NAILED To PRI❑R STUD W/
<br />(2) ROWS OF 2d NAILS AT 10' C/C,
<br />GYPSUM WALLBOARD
<br />PR❑VIDE 1/2' NO SAG GYP, BOARD ON ALL CEILINGS. PR❑VIDE 5/8' TYPE 'X" GYP, BP❑ARD ON ALL
<br />GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE. GARAGE SHALL BE SEPARATED FROM THE
<br />RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP. BOARD APPLIED TO THE GARAGE SIDE.
<br />HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB L❑CATI❑NS, UP TO 8' kF,F.
<br />N❑N-BEARING INTERI❑R PARTITI❑NS
<br />ALL INTERI❑R NON BEARING PARTITI❑NS SHALL BE 2X4 SPF @ 16' ❑.C, MAX. SPACING WITH SINGLE TOP
<br />AND BOTTOM PLATE W/ 1/2' GYP, DRYWALL EACH SIDE.
<br />FLORIDA APPROVED PRODUCTS LIST
<br />Parent Approval Manufacturer Category Subcategory App/Seq # Product Model # or Name Model Description
<br />FL15220.6 Plastico Inc. Exterior Doors Swinging Ext. Door Opaque _Fiberglass Door En �YDoor
<br />FL15220.5 Plastico, Inc. Exterior Doors Swinging Ext. Door Assemblies Opaque Fiberglass Door Glazed Fiberglass Door
<br />FL15279-R5 �Clopay Building_ Products Company Exterior Doors_ Sectional Ext. Door Assemblies
<br />FL14911-R8 SHverline Bldg. Products Windows - Single -Hung Aluminum
<br />FL14911-R9 Silverline Bldg. Products Windows Single -Hung _ -_ Aluminum
<br />FL6067-R7 Silverline Bldg. Products Windows Mullion Aluminum
<br />FL16626_1-R3 Tamko Building Products _ - Roofing Underlayments _ _- TW Underlayment
<br />FL10674.1 Owens Corning Roofing Asphalt Shingles Fiberglass Reinforced
<br />FL13192.2 James Hardie Bldg. Products Panel Walls Exterior Siding Hardie Plank Cement Board
<br />FL15272 Alside Panel Walls Soffits - - Aluminum
<br />FL11473-R2 Simpson Strong -Tie Co. Structural Components Truss Anchors HETA20 Embedded Truss Anchor
<br />FL11473-R2 Simpson Strong -Tie Co. _ Structural Components_ Truss And
<br />hrns META Embedded Truss Anchor
<br />FL10456.2-R4 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors - H2,5
<br />FL10456.10-R4 I Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors SP1
<br />FL10456.10-R4 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors I S P2 -_
<br />FL11473-R2 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors _ LSTA12 Strap Ties
<br />FL11463.2 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors H1 Tie
<br />FL10860.1 Simpson Strong -Tie Co. Structural Components _ Wood Connectors Anchors ABA66 Post Base
<br />FL10860.2 _ Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors ABU66 Post Base
<br />FL10860.4 _ _ Simpson Strong -Tie Co. Structural_ Components Wood Connectors Anchors AC6 _ Post Cap
<br />FL10860.5 Simpson Strong -Tie Co. Structural Components Wood Connectors Anchors BC6 Post Cap
<br />FBCR 2017 - COMPONENTS AND CLADDING - EXP. "B"
<br />140 Ult - DESIGN WIND PRESSURE FOR WALLS, DOORS & WIND❑WS (N❑MINAL)
<br />COMPONENT
<br />ZONE
<br />EFFECTIVE WIND AREA
<br />WALL
<br />10 SQ. FT.
<br />20 SQ, FT.
<br />50 SQ, FT,
<br />100 SQ. FT.
<br />500 SQ, FT.
<br />WALL
<br />O
<br />+21.2 PSF / -22.0 PSF
<br />+20.2 PSF / -22.0 PSF
<br />+19.0 PSF / -20.0 PSF
<br />+18,0 PSF / -19.0 PSF
<br />+15.8 PSF / -17,0 PSF
<br />WALL
<br />l5)
<br />+21.2 PSF / -28.0 PSF
<br />+20.2 PSF / -26.0 PSF
<br />+19.0 PSF / -23.0 PSF
<br />+18.0 PSF / -22.0 PSF
<br />+15.8 PSF / -17.0 PSF
<br />N❑TE1
<br />ALL EXTERI❑R DOORS & WIND❑WS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2017. ALL C❑NNECTI❑NS TO BUILDING STRUCTURE
<br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE,
<br />3'-0" FROM THE BUILDING EDGE GOVERNS FOR ZONE 5,
<br />DESIGN ❑PENING PRESSURES
<br />ENCLOSED BUILDING EXPOSURE 'B'
<br />TAG
<br />D❑❑R/WIND❑W
<br />LISTED
<br />ZONE
<br />PRESSURE
<br />N❑MINAL SIZE
<br />A
<br />3068 DR.
<br />4
<br />20.2
<br />22
<br />B
<br />2868 DR,
<br />4
<br />21.2
<br />22
<br />C
<br />2868 DR.
<br />4
<br />212
<br />22
<br />D
<br />5068 FR. DR.
<br />4
<br />20.2
<br />22
<br />E
<br />16070 ❑HD
<br />4
<br />18.0
<br />19
<br />F
<br />37x63
<br />25 SH
<br />4
<br />202
<br />22
<br />G
<br />37x63
<br />25 SH
<br />5
<br />20.2
<br />28
<br />H
<br />37x38
<br />23 SH
<br />4
<br />21.2
<br />22
<br />J
<br />erg.
<br />u.-Ul-l-DINE OFf ICIA L_.
<br />M51P�N & PLAN CH�CKI 15T M� FLRIPA PU PINCACOn� 6TH, �n1110N ( 2011)
<br />1,11�rPING t OOM5 HAVF Vb QUAT WIN12OW 51ZF ANn PLOPP, LOCAT10N FOF �5GPFF & IT5CUr (FPC-IT5112�NflK 1310)
<br />Z ONE BATH/ TOILFT VOOM WITH A 29'' MINIMUM CLAP ACC�55, ON T W LOM� FLOOf , (FPC-F�5112�NT1AL P,502)
<br />3, HAZAPt2OU5 GLA55 LOCAT10N5 INPICAtP. �08,4)
<br />4, AMC ACCr55 LOCAtP WITH 01`�NIN6 PIM51ON5, F501)
<br />5, PPOVIP� PPOTC110N FkOM IMPACT IN 6ARA6F5 FOP, PUCTNOPK ANb APPLIANa5,
<br />(FT3C-M51MN11AI, MI5W, W-ACCHANICAI, 603,15, FBC-FTL 6iA5 50M)
<br />6, 5TAII? CON5VUC110N Pff&5 INPICAT PrOp�p VFAW P&ATION511Ip, HANPPAIL LOCATION, HAN12ML/ GUAOXAIL
<br />WW5, ANn MAXIMUM OMN IZ& 5PACIN6 IWICAM9, (F13C-W51MNfl& 011,1, 012,1)
<br />I, FLA5HIN6 P�TIL5 AT �XT�MOI? WINnOW5/ POOP OPFNIN65, INT�P,5ECT10N5WIT1-I CHIMNFY/ MA50NPY/ FTC„ P�OJFCTING
<br />WOOn VIM, WERIOR MCK5/ FMCH�5/ 5T *5, WAI U ROOF INTEMCTI10N5,WWM, M. ( FPGBULL91NI6101,2.4,
<br />8, 5MOK� PFtCT01?5 ANb CAl DON MONOXIP� b�TCTO�5 (FPC4�5I12FNT1AL 314, P,�?15>
<br />9, POVIn� 1001` V�N11LA110N CALCUI,A110N5, I?806)
<br />10, PkOVInF 12FTAIL5 FOP PMWNG GAFAG� OFFNING ANn P�NFTp�AT10N PPOTCT10N, PP\OVIPF 12FTAIL5 FOV PV&LIN6-6APA61�
<br />FIM %FAPAT10N, (Fj3C-W51PeN% 00265, 0W.6)
<br />I I , I`POVIP� LOCATION OF ALL fWUIFb 61`1/ AEI ANn WATT PFOOF PFaPTACL�5, (FPC-PF511)�N11AI, ��90I, F 002)
<br />1Z FPZOVIP� MINIMUM 157- HIGH-FFFICI%CY LIGHTING, (F13C-%N P,6Y CON5FPVATION p404)
<br />REQUIRED ATTIC VENTILATION
<br />AREA OF ATTIC
<br />2511
<br />NET FREE VENTILATION AREA REQ'D.
<br />1/300
<br />REQ'D. VENTILATION ATTIC
<br />2511/300
<br />9.25
<br />VENTILATION AREA x SQ. INCHES PER FOOT (144)
<br />1332
<br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC
<br />666
<br />OFF RIDGE VENTILATION AREA 115
<br />SQ. INCH PER VENT
<br />666/115
<br />TOTAL # OF VENTS REQUIRED
<br />5.79
<br />TOTAL # OF VENTS PROVIDED
<br />6
<br />SOFFIT VENTILATION AREA 11.736
<br />SQ, INCH PER PER L.F.
<br />666/11.736
<br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED
<br />56.75
<br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE
<br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS
<br />INCLUDED)
<br />DRAWING PAGE INDEX
<br />BF-002-Al
<br />-
<br />ENGINEERING NOTES
<br />BF-002-A2
<br />- FLOOR PLAN
<br />BF-002-A3
<br />- ELEVATIONS
<br />BF-002-A4
<br />- FOUNDATION PLAN
<br />BF-002-A5
<br />- ROOF PLAN
<br />BF-002-A6
<br />- ELECTRICAL PLAN
<br />BF-002-A7
<br />- WALL SECTION & DETAILS
<br />BF-002-A8
<br />- ROOF NAILING
<br />BF-002-A9
<br />- GABLE
<br />TRUSS
<br />DETAILS
<br />I HEREBY CERTIFY THAT I HAVE REVIEWED
<br />THIS PLAN AND FOUND IT TO BE IN
<br />COMPLIANCE WITH ASCE 7-10, & FBC 2017
<br />(6TH. EDITION).
<br />�tX vy L'fill i i 40
<br />•��� J ••• E ••• «,�''o
<br />«
<br />No. 53608 r
<br />Alp
<br />!'gyp•'SyAlklF :• ��
<br />••IpR�OP.
<br />* 111111i,�®��
<br />PROFESSIONAL ENGINEER SEAL
<br />ENGINEER OF RECORD
<br />David W. Smith P.E.
<br />FLORIDA LICBNSB NUMBER: 53608
<br />Plans By:
<br />Larry deMontmollin
<br />90 Country Club Lane
<br />Mulberry, FL 33860
<br />Phone: (863)397-7525
<br />DATE: 02-08-19
<br />DRAWN BY: L.E.D.
<br />REVISION: I DATE:
<br />R01
<br />RO 2
<br />RO 3
<br />RO 4
<br />PROJECT ADDRESS:
<br />BUTTERFIELD INVESTMENTS, INC.
<br />501018th. STREET
<br />ZEPHYRHILLS, FL. 33542
<br />CONTRACTOR:
<br />le�� ulun
<br />HOUSE PLAN
<br />NOTES & SPECS.
<br />DWG, BF-002-Al REV, 0
<br />NOTE ZIP, FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS.
<br />
|