Laserfiche WebLink
SWIMMING POOL <br />EQUIPMENT AREA <br />(SEE DETAILS) <br />DECK NOTES: <br />1. DECK SHALL HAVE A SMOOTH, SLIP RESISTANT FINISH. <br />2. DECK SHALL HAVE NO PITTING OR CREVICES MORE <br />THAN 3/16" DEEP. <br />3. IF SETTLING OR WEATHERING OF THE DECK OCCURS <br />THAT WOULD CAUSE STANDING WATER, THE ORIGINAL <br />SLOPES SHALL BE RESTORED OR CORRECTIVE DRAINS <br />INSTALLED. <br />4. DECK AREAS SHALL UNIFORMLY SLOPE 2% AWAY FROM <br />POOL TOWARD DRAINS OR PERVIOUS AREA (EXCEPT AS <br />NOTED IN ZERO ENTRY AREAS, IF APPLICABLE). <br />5. IF A CURB IS PROVIDED, DECK MUST BE LESS THAN <br />10" FROM TOP OF CURB. <br />6. POOL DECK SHALL HAVE MINIMUM 4 FEET OF <br />UNOBSTRUCTED WIDTH AROUND PERIMETER OF POOL, <br />HANDRAIL AND LADDER ANCHORS, AND SLIDES. <br />7. TRAFFIC BARRIERS ARE REQUIRED TO PREVENT <br />OBSTRUCTION OF DECK BY VEHICLES (WHERE <br />APPLICABLE). <br />8. HOSE BIBB WITH VACUUM BREAKER SHALL BE PROVIDED <br />TO WASH DECK WITH POTABLE WATER. <br />9. THE VERTICAL CLEARANCE ABOVE THE POOL DECK <br />SHALL BE AT LEAST 7 FEET. <br />THIS PLAN REMAINS THE PROPERTY OF AQUATIC <br />CONSULTING ENGINEERS, INC. (ACE), AND IS NOT <br />TRANSFERABLE FROM ONE CONTRACTOR TO <br />ANOTHER WITHOUT WRITTEN PERMISSION OF ACE. <br />THE ENGINEER STRONGLY REQUIRES CONTRACTOR <br />BUILD FROM PLANS AS APPROVED BY "HE LOCAL <br />BUILDING DEPARTMENT AND THE FLORIDA <br />DEPARTMENT OF HEALTH. ACE IS NOT <br />RESPONSIBLE FOR CONSTRUCTION ERRORS OR <br />OMISSIONS RESULTING FROM FAILURE TO COMPLY <br />WITH THIS REQUIREMENT. <br />POOL WET DECKS SHALL BE <br />UNIFORMLY SLOPED 2% AWAY FROM <br />THE POOL(S) OR TO DECK DRAINS <br />TO PREVENT STANDING WATER. <br />(DECK DRAINS BY OTHERS) <br />TO POOL <br />ELECTRIC PANEL <br />W/ TIMER FORS <br />LIGHTS <br />(BY OTHERS) <br />J-BOX & <br />LOW VOLTAGE <br />TRANSFORMER <br />FOR LOW <br />VOLTAGE <br />POOL LIGHTS <br />SHOWER AND HOSE BIBB WITH <br />APPROVED BACKFLOW PREVENTER <br />INSTALL WITHIN <br />THE CONFINES OF APPROVED <br />POOL BARRIER <br />1" RIG!D PVC <br />CONDUIT W/ <br />PRE-WIREC POOL <br />LIGHT CORD <br />(BY OTHERS) <br />POOL SAFETY SWIMMING POOL RULES <br />EQUIPMENT <br />_ (MOUNT IN A SIGN W/SUNSHELF RULES <br />CONSPICUOUS AND (SEE REQUIREMENTS - <br />READILY BY OTHERS) <br />ACCESSIBLE <br />LOCATION ALONG <br />LONGER SIDES OF <br />PLANTER EACH POOL) 11' <br />(BY OTHERS) (TYPICAL OF 2) <br />7. <br />�e <br />.. <br />4'-2" j O <br />i <br />/ <br />4 • <br />I, <br />38'-7" I. PROPOSE <br />�. .� COMMERCI <br />SWIMMING F <br />DECK LEVEL <br />PLANTER (FLUSH) 4'-5" J <br />(TYP., BY OTHERS) <br />1" RIGID PVC CONDUIT <br />W/ PRE -WIRED POOL <br />LIGHT CORD (BY <br />OTHERS) <br />Tiff <br />PLANTER <br />(BY OTHERS) <br />13'-3" <br />OBSTRUCTED <br />POOL PERIMETER <br />PERMANENT <br />"NO ENTRY" <br />SIGNS OR <br />MARKERS <br />SHALL BE <br />INSTALLED <br />TO <br />DISCOURAGE <br />PATRON <br />? ACCESS <br />SWIMMING POOL RULES <br />SIGN W/SUNSHELF RULES <br />(SEE REQUIREMENTS - <br />BY OTHERS) <br />(VERIFY LOCATION IN FIELD) <br />NOTE: <br />EQUIPMENT AREA SHALL BE <br />ILLUMINATED WITH 30 FC MIN. <br />ILLUMINATION AT FLOOR LEVEL. <br />--_ --- m <br />i <br />ii <br />I <br />I <br />I <br />i <br />PLANTER m <br />(BY OTHERS) <br />i <br />I <br />l � � <br />I r 4'- 3 <br />m <br />© � m <br />I-T- <br />13'- 3" <br />OBSTRUCTED <br />POOL PERIMETER <br />F-4 , <br />DECK LEVEL <br />---PLANTER (FLUSH) <br />(TYP., BY OTHERS) , <br />ALL DOORS, <br />WINDOWS, AND GATES <br />AREA PLAN LEADING TO POOL <br />NORTH DECK SHALL MEET <br />SCALE: 3/32'p = 1 -0" FBC POOL BARRIER <br />REQUIREMENTS <br />LANDSCAPE IRRIGATION WATER REQUIREMENTS: NOTE: <br />FOOD OR DRINK SERVICE <br />LANDSCAPE IRRIGATION WATER THAT WETS THE WET DECK AREA OF THE POOL, THE POOL ITSELF, ENTERS FACILITIES SHALL NOT BE <br />THE COLLECTOR TANK, OR WETS AN INTERACTIVE WATER FEATURE MUST BE POTABLE WATER FROM A LOCATED WITHIN 12 FEET <br />PUBLIC WATER SYSTEM OR SHALL MEET THE BACTERIOLOGICAL QUALITY OF POTABLE WATER AS EVIDENCED (3,658 MM) OF THE <br />BY ANNUAL LABORATORY ANALYSIS SUBMITTED TO THE DEPARTMENT OF HEALTH. RECLAIMED WATER MAY WATER'S EDGE. <br />NOT BE USED IN THESE AREAS. IF RECLAIMED WATER IS USED IN THE VICINITY OF THE POOL (INSIDE OF <br />THE POOL FENCE WITHIN 100 FEET OF THE POOL WATER'S EDGE) IT MUST EMPLOY DRIP IRRIGATION OR <br />SOAKER HOSES. SIGNS SHALL BE POSTED NOTIFYING POOL PATRONS THAT RECLAIMED WATER IS IN USE, <br />AND IS NOT TO BE CONSUMED. <br />NOTE: NOTE: <br />PROVIDE CONTINUOUS 4 FEET WIDE EXCESS FILL SHALL <br />CLEAR WET DECK AROUND ENTIRE BE HAULED <br />SWIMMING POOL PERIMETER. OFFSITE. <br />NOTE: <br />(2) WP 125V, 15A OR 20A GFCI RECEPTACLE <br />ON A GENERAL PURPOSE CIRCUIT SHALL BE <br />LOCATED AT OPPOSITE ENDS OF EACH POOL, <br />BETWEEN 6' MIN. TO 20' MAX. FROM WATER <br />AND MOUNTED NOT LESS THAN 8" ABOVE <br />MAX. WATER LEVEL OR 4" ABOVE POOL DECK <br />(WHICHEVER IS GREATER) AND NOT MORE <br />THAN 6'-6" ABOVE POOL DECK TO <br />FACILITATE POOL MAINTENANCE (BY OTHERS) <br />THESE PLANS ARE RELEVANT TO THE <br />POOL & POOL EQUIPMENT ONLY. <br />RESTROOM INFORMATION IS SHOWN FOR <br />REFERENCE PURPOSES ONLY. <br />RESTROOM CONSTRUCTION IS BY <br />OTHERS UNDER SEPARATE PERMIT. <br />POOL DECK, FENCING, GATES & <br />LANDSCAPING IS BY OTHERS UNDER <br />SEPARATE PERMIT. <br />NOTE: <br />NO HIGH VOLTAGE ELECTRIC (>12V) <br />PERMITTED WITHIN 5' OF POOL WATER - <br />ELECTRIC OVER 12V AND LESS THAN 10' <br />FROM POOL (WHILE STILL AT LEAST 5' <br />FROM POOL WATER) MUST BE GFCI <br />PROTECTED <br />BARRIER NOTES: <br />1. FENCE AND GATES UNDER SEPARATE PERMIT BY OTHERS- ONLY SHOWN ON <br />PLANS FOR REFERENCE PURPOSES. <br />2. ACCESS THROUGH THE FENCE FROM DWELLING UNITS SHALL BE VIA MINIMUM <br />48" HIGH SELF -CLOSING, SELF -LATCHING LOCKABLE GATES. OPERABLE PARTS <br />USED FOR OPENING DOORS AT THESE ACCESS POINTS SHALL BE 45 INCHES <br />(1143 MM) MINIMUM TO 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH <br />FLOOR OR GROUND. <br />3. DOORED ACCESS FROM PUBLIC ROOMS NEED NOT BE THROUGH GATE, IF THE <br />DOORS MEET THE SAME SELF -CLOSING, SELF -LATCHING REQUIREMENTS AS A <br />GATE. <br />4. PERMANENT NATURAL OR MANMADE FEATURES SUCH AS BULKHEADS, CANALS, <br />LAKES, NAVIGABLE WATERWAYS, ETC. ADJACENT TO A POOL MAY BE PERMITTED <br />AS A BARRIER WHEN APPROVED. <br />5. A LATCHED, LOCKABLE GATE SHALL BE PLACED IN THE FENCE WITHIN 10 FEET <br />OF THE CLOSEST POINT BETWEEN THE POOL AND THE EQUIPMENT AREA FOR <br />SERVICE ACCESS. <br />NIGHT SWIMMING REQUIREMENTS: <br />THESE POOLS ARE NOT DESIGNED OR INTENDED FOR NIGHT SWIMMING. <br />IN ORDER FOR NIGHT SWIMMING TO BE AUTHORIZED, THE FOLLOWING MUST BE DONE: <br />1. OVERHEAD LIGHTING IN ACCORDANCE WITH FBC 454.1.4.2.1 MUST BE INSTALLED. <br />2. THE LIGHTING MUST BE CERTIFIED BY A FLORIDA REGISTERED ENGINEER. <br />3. HEALTH DEPARTMENT APPROVAL MUST BE OBTAINED. <br />NOTE: <br />ALL FINISHES SHOWN ON THESE DRAWINGS ARE GENERIC. ALL FINISH <br />MATERIALS (INCLUDING, BUT NOT LIMITED TO, ADHESIVES, GROUTS, <br />AND BONDING AGENTS) SHALL BE MANUFACTURER SPECIFIED AS <br />SUITABLE FOR USE IN POOL/SPA APPLICATIONS. <br />ALL MATERIAL INSTALLATIONS SHALL COMPLY WITH FBC, ALL <br />RELEVANT INDUSTRY STANDARDS, AND ALL MANUFACTURER <br />INSTRUCTIONS AND SPECIFICATIONS. <br />ALL MATERIALS AND FINISHES USED ON HORIZONTAL SURFACES <br />SHALL BE SLIP RESISTANT WHEN WET. <br />TE: <br />ESE PLANS DO NOT INCLUDE ALL TECHNICAL <br />ECIFICATIONS REQUIRED FOR CONSTRUCTION. LICENSED <br />NTRACTOR SHALL REFERENCE ALL MANUFACTURER <br />;TRUCTIONS AND SPECIFICATIONS. <br />m <br />0 0 <br />0 <br />TO POOL <br />ELECTRIC PANEL <br />W/ TIMER FOR <br />LIGHTS <br />(BY OTHERS) <br />J-BOX & <br />LOW VOLTAGE <br />TRANSFORMER <br />FOR LOW <br />VOLTAGE <br />POOL LIGHTS <br />. o ❑ ❑ <br />POOL SHALL BE ENCLOSED BY A <br />MIN. 48" HIGH FENCE AND THE <br />BUILDING WITH SELF -CLOSING, <br />SELF -LATCHING LOCKABLE GATES <br />OPENING AWAY FROM POOL. <br />GATE LATCHES SHALL BE 54" <br />ABOVE BOTTOM OF GATE OR <br />MINIMUM 3" BELOW THE TOP OF <br />GATE ON POOL SIDE. BARRIER <br />SHALL NOT ALLOW PASSAGE OF <br />4" DIAMETER SPHERE. LOCKS, IF <br />SELF-LOCKING, MAY BE 34" <br />MINIMUM AND 48" MAXIMUM <br />ABOVE THE FINISHED FLOOR OR <br />GROUND. <br />!FDoH POOL NOTES INDEX: <br />1. POOL LAYOUT NOTES - SEE SHEET 3 <br />2. RESTROOM NOTES - SEE SHEET 2 <br />3. EQUIPMENT ROOM/ENCLOSURE NOTES - SEE SHEET 6 <br />4. FOUNDATION NOTE - SEE SHEET 9 <br />5. CONCRETE & REINFORCEMENT NOTE - SEE SHEET 9 <br />6. MISCELLANEOUS NOTES - SEE SHEET 2 <br />7. DECK NOTES - SEE SHEET 1 <br />8. BARRIER NOTES - SEE SHEET 1 <br />9. LANDSCAPE IRRIGATION WATER NOTES - SEE SHEET 1 <br />10. NIGHT SWIMMING REQUIREMENTS - SEE SHEET 1 <br />10.1. NOTE: POOL NOT DESIGNED FOR NIGHT SWIMMING <br />11. POOL EQUIPMENT NOTES - SEE SHEETS 10 <br />12. AMERICANS W/ DISABILITIES ACT NOTE - SEE SHEET 2 <br />454.1.4.2 LIGHTING. <br />ARTIFICIAL LIGHTING SHALL BE PROVIDED AT ALL SWIMMING POOLS WHICH ARE TO BE USED AT NIGHT OR WHICH DO <br />NOT HAVE ADEQUATE NATURAL LIGHTING SO THAT ALL PORTIONS OF THE POOL, INCLUDING THE BOTTOM, MAY BE <br />READILY SEEN WITHOUT GLARE. <br />454.1.4.2.1 OUTDOOR POOL LIGHTING. <br />LIGHTING SHALL PROVIDE A MINIMUM OF 3 FOOTCANDLES (30 LUX) OF ILLUMINATION AT THE POOL WATER SURFACE <br />AND THE POOL WET DECK SURFACE. UNDERWATER LIGHTING SHALL BE A MINIMUM OF 1 /2 WATT INCANDESCENT <br />EQUIVALENT, OR 10 LUMENS, PER SQUARE FOOT OF POOL WATER SURFACE AREA. <br />454.1.4.2.3 UNDERWATER LIGHTING. <br />UNDERWATER LUMINAIRES SHALL COMPLY WITH CHAPTER 27 OF THE FLORIDA BUILDING CODE, BUILDING. THE LOCATION <br />OF THE UNDERWATER LUMINAIRES SHALL BE SUCH THAT THE UNDERWATER ILLUMINATION IS AS UNIFORM AS POSSIBLE. <br />UNDERWATER LIGHTING REQUIREMENTS CAN BE WAIVED WHEN THE OVERHEAD LIGHTING PROVIDES AT LEAST 15 <br />FOOTCANDLES (150 LUX) OF ILLUMINATION AT THE POOL WATER SURFACE AND POOL WET DECK SURFACE. <br />454.1.4.2.5VOLTAGE LIMITATION. <br />UNDERWATER LIGHTING, OR LIGHTING THAT MAY BE EXPOSED TO NOZZLEDIRECTED POOL WATER, SHALL NOT EXCEED 30 <br />VOLTS DC OR 15 VOLTS AC. SUCH LIGHTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS AND BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. <br />David <br />Faerman <br />PoE <br />Digitally signed -q <br />by <br />David � <br />Faerman, RE <br />Date: 2023.01.13 <br />16:23:44-05'00' <br />ALL WORK SHALL COMPLY WITH PREVAIL <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />IN -GROUND <br />AYB 2 <br />COMMERCIAL SWIMMING <br />POOL'ITYOF®ATE <br />�� ZEPN��WI <br />DESIGN DATA <br />FINER <br />NUMBER OF LIVING UNITS <br />252 <br />LODGING STATUS <br />NON -TRANSIENT <br />NOMINAL DIMENSIONS <br />go,-O" X 61'-9" <br />PERIMETER <br />260 L.F. <br />MINIMUM REQUIRED POOL AREA* <br />728 S.F. <br />DESIGN SURF/\CE AREA (SWIMMING POOL) <br />2,495 S.F. <br />DEPTH <br />0'-0" TO 5'-0" TO 3'-6- <br />VOLUME <br />56,685 GALLONS <br />DESIGN RECIRC. FLOW RATE <br />260 GPM <br />DESIGN TURNOVER TIME <br />3.6 HOURS <br />MINIMUM TOTAL FACILITY BATHING LOAD* <br />36 BATHERS <br />DESIGN DATH NG LOAD (SWIMMING POOL) <br />52 BATHERS <br />*MINIMUM WATER SURFACE AREA AND BATHING LOAD CAPACITY SUFFICIENT TO SUPPORT 252 NON -TRANSIENT LIVING <br />UNITS <br />NOTE: <br />TOTAL OBSTRUCTED PERIMETER = 26.5 L.F. (10.2%) <br />MAXIMUM INDIVIDUAL OBSTRUCTION LENGTH = 13.2 L.F. (5.1%) <br />UP TO TWENTY PERCENT CF THE DECK ALONG THE POOL PERIMETER MAY BE OBSTRUCTED AS LONG AS ANY ONE <br />OBSTRUCTION DOES NOT EXCEED 10 PERCENT OF THE POOL PERIMETER OR <br />20 FEET (6096 MM), WHICHEVER IS LESS, <br />IN ANY ONE AREA MERE WATER DEPTH IS 5 FEET (1524 MM) OR LESS. <br />OBSTRUCTIONS SHALL HAVI: A MIN. 4'-0" WIDE WET DECK AREA BEHIND OR THROUGH THEM, WITH THE NEAR EDGE <br />OF THE WALK WITHIN 15 F1=ET (4572 MM) OF THE WATER. <br />NOTE: <br />THE POOL, POOL DESK. AND POOL EQUIPMENT, AS ILLUSTRATED ON THESE <br />ENGINEERED PLANS, MEET THE <br />REQUIREMENTS OF FBC-B 454.1 (2020) AND NEC (2017). <br />U) <br />z <br />I <br />w� <br />0 <br />Q <br />z�op� <br />z <br />0 <br />c, 0 <br />� Ln U <br />w��z�=o <br />0 <br />V) <br />Q <br />ILL <br />uj <br />G <br />J uj <br />LLJ <br />Cn <br />N <br />{C3 <br />7 <br />N <br />N <br />N <br />OLL_ <br />l <br />Q1 <br />o <br />� <br />Q <br />c <br />o0 <br />Ld <br />w <br />crJ <br />a- <br />O <br />3: <br />y C <br />z <br />to <br />w <br />(DO J <br />LLJ <br />O w N <br />Q <br />Q'C <br />Ld Z �. Q <br />Ld <br />00 <br />cl- <br />< 00 w <br />W <br />c1f _w <br />Li.l a <br />LL <br />Uc <br />N w <br />00 _J <br />l <br />I <br />w <br />PROJECT NO. <br />22CO93 <br />Qo <br />0 <br />z0 Z U <br />Zw <br />= <br />�~ <br />(nU <br />�LLL <br />W Q <br />Q p <br />2 x< F <br />z Q Q <br />V) CL <br />W p Z <br />�.wJO <br />JQ0 <br />_j z <br />0Wuj <br />F-�00 <br />0�� <br />Caw " <br />(n0ll�w <br />w -o< <br />LL0w <br />wQwZ <br />m5�- <br />Owmw <br />cnLDccnC) <br />cnQZo� <br />wV)1� <br />_ U Q O <br />. <br />cc U <br />W w <br />m w <br />U - <br />w <br />F-� WwN <br />J Z 0 <br />H0�of <br />Fn Q~ <br />�Q C�w� <br />ZZZU <br />�cww�to <br />n <br />0 <br />-Ucnw <br />`���,•�`��� �� L F AE�'f <br />* ; No. 47646 <br />STATE OF r <br />r0OR fJ <br />'. <br />(V <br />S10NAI.E���``� <br />01 /13/2023 <br />DAVID I FAERMAN, P.E. <br />FL. LICENSE NO. 47646 <br />PERMIT SET <br />NO. DATE I DESCRIPTION <br />SHEET <br />1 OF 11 <br />