I
<br />List Of Abbreviations
<br />A A/C AIR CONDITION E EL ELEVATION L LAV LAVATORY S SC SOLID CORE
<br />AB ANCHOR BOLT ELEC ELECTRICAL LBL LABEL SCHED SCHEDULE
<br />ACT ACOUSTICAL CEILING TILE ELEV ELEVATOR LBS POUNDS SCP SCUPPER
<br />AD ADJUSTABLE, ADJACENT EMER EMERGENCY LF LINEAR FEET SD SOAP DISPENSER
<br />AFF ABOVE REF FINISHED EQ EQUAL LT WT LIGHT WEIGHT SEAL SEALANT
<br />FLOOR (SLAB) EQUIP EQUIPMENT SECT SECTION
<br />AHU AIR HANDLER UNIT ESC ESCALATOR M MAS MASONRY SF SQUARE FEET
<br />ALT ALTERNATE EWC ELECTRIC MAX MAXIMUM SHT SHEET
<br />ALUM ALUMINUM WATER COOLER MECH MECHANICAL SIM SIMILAR
<br />ANOD ANODIZED EXIST EXISTING MFR MANUFACTURER SPEC SPECIFICATION
<br />APPROX APPROXIMATE EXP EXPANSION MH MANHOLE SS STAINLESS STEEL,
<br />ARCH ARCHITECT EXT EXTERIOR MIN MINIMUM SERVICE SINK
<br />AUTO AUTOMATIC MIN MINIMUM, MINUTE STD STANDARD
<br />F FACP FIRE ALARM MISC MISCELLANEOUS STL STEEL
<br />B B 0 BOTTOM OF CONTROL PANEL MLDG MOLDING STOR STORAGE
<br />BD BOARD FD FLOOR DRAIN MO MASONRY OPENING STRUC STRUCTURAL
<br />BLDG BUILDING FDN FOUNDATION MR MOISTURE RESISTANT SUSP SUSPENDED
<br />BM BEAM FIN FINISHED MTD MOUNTED SY SQUARE YARD
<br />BRG BEARING FLR FLOOR MTL METAL
<br />BTM BOTTOM FR FIRE RESISTANT MUL MULLION T T TREAD
<br />BUR BUILT UP ROOF FR-S FIRE -RETARDANT T&G TONGUE & GROOVE
<br />WOOD TREATMENT N NIC NOT IN CONTRACT TBL TABLE
<br />C CB CATCH BASIN FT FEET, FOOT NOM NOMINAL TELE TELEPHONE
<br />CG CORNER GUARD FTG FOOTING NTS NOT TO SCALE TEMP TEMPERED
<br />Cl CAST IRON FURR FURRING THK THICK
<br />CJ CONTROL JOINT FLIT FUTURE 0 OC ON CENTER TLT TOILET
<br />CL CENTER LINE OD OUTSIDE DIAMETER TO TOP OF
<br />CLG CEILING G GA GAUGE OPP OPPOSITE TPD TOILET PAPER
<br />CLO CLOSET GAL GALLON OVFL OVERFLOW DISPENSER
<br />CLR CLEAR GALV GALVANIZED TS TUBE STEEL
<br />CMU CONCRETE GB GRAB BAR P PL PLATE TV TELEVISION
<br />MASONRY UNIT GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TYP TYPICAL
<br />CO CLEAN OUT GYP GYPSUM PLAS PLASTER
<br />COL COLUMN PLBG PLUMBING U LION UNLESS OTHER-
<br />CONC CONCRETE H HB HOSE BIBB PLWD PLYWOOD WISE NOTED
<br />CONST CONSTRUCTION HC HOLLOW CORE PNL PANEL UTIL UTILITY
<br />CONT CONTINUOUS HDW HARDWARE PR PAIR
<br />CONTR CONTRACTOR HM HOLLOW METAL PREFAB PREFABRICATED V VB VINYL BASE
<br />CORR CORRIDOR HORIZ HORIZONTAL PT POINT VCT VINYL COMPOSITE TILE
<br />CT CERAMIC TILE HR HOUR PT PRESSURE TREATED VERT VERTICAL-.
<br />CTR CENTER HT HEIGHT PTD PAPER TOWEL DISPENSER VEST VESTIBULE
<br />CU CONDENSING UNIT HTG HEATING PVC POLY VINYL CLORIDE VIF VERIFY IN FIELD
<br />CW COLD WATER HVAC HEATING, VENTILATING VTR VENT THRU ROOF
<br />& AIR CONDITIONING Q QT QUARRY TILE VWC VINYL WALL COVERING
<br />D DBL DOUBLE HW HOT WATER
<br />DEPT DEPARTMENT R R RADIUS, RISER, W W WIDTH
<br />DET DETAIL I ID INSIDE DIAMETER THERMAL RESISTANCE W/ WITH
<br />DF DRINKING FOUNTAIN IN INCH RD ROOF DRAIN WIO WITHOUT
<br />DIA DIAMETER INCL INCLUDING RECP RECEPTACLE WC WATER CLOSET
<br />DIM DIMENSION INSUL INSULATION REF REFERENCE WD WOOD
<br />DISP DISPENSER INT INTERIOR REFR REFRIGERATOR WH WATER HEATER
<br />DN DOWN INV INVERT REG REGLET WP WATERPROOF
<br />DS DOWNSPOUT REINF REINFORCEMENT WT WEIGHT
<br />DWG DRAWING J JAN JANITOR REQ REQUIRED WWF WELDED WIRE FABRIC
<br />JB JUNCTION BOX REV REVISION WWM WELDED WIRE METAL
<br />E EA EACH JT JOINT RM ROOM
<br />EB EXPANSION BOLT RND ROUND Y YD YARD
<br />EIFS EXTERIOR INSULATING L L LENGTH RO ROUGH OPENING
<br />FINISH SYSTEM LAM LAMINATE RTU ROOF TOP UNIT
<br />EJ EXPANSION JOINT
<br />Legend
<br />X -- GRID DESIGNATION _ . BUILDING SECTION
<br />A 1-2 A301-2
<br />102 ROOM NUMBER SHEET NUMBER SECTION NUMBER
<br />102A DOOR NUMBER _,. ..... WALL SECTION
<br />A302-3
<br />WINDOW TYPE SHEET NUMBER ' SECTION NUMBER
<br />2 STOREFRONT TYPE A501 6 0 SECTION DETAIL
<br />3- WALL TYPE SHEET NUMBER DETAIL NUMBER
<br />5 KEY NOTE A888-88 DETAIL REFERENCE
<br />A6 REVISION NUMBER SHEET NUMBER DETAIL NUMBER
<br />,�. T n SOn�ETNilur �
<br />- ELLvhi (OIL.7 Ir►va `i rzz
<br />�✓\I : `ivy tLL4Hi \%1V
<br />A201-2 o MARKERS
<br />T
<br />-�' SHEET NUMBER ELEVATION NUMBER
<br />SPOT ELEVATION TAG
<br />1
<br />4 < A401 ;> 2 INTERIOR ELEVATION
<br />MARKERS
<br />s NORTH ARROW
<br />SHEET NUMBER 3 ELEVATION NUMBER
<br />a
<br />BRICK CONCRETE
<br />PLYWOOD ..
<br />GYP SUM
<br />BOARD
<br />DRAINAGE
<br />G E
<br />FILL
<br />2G
<br />MASONRY 1 COMPACTED
<br />STEEL
<br />##
<br />RIGID
<br />INSULATION
<br />: ` ; :: ; ::::: MR
<br />BOARD
<br />N EARTH
<br />_• • . - - ..:::
<br />General Notes
<br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES
<br />7. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO
<br />RELATED TO THIS PROJECT.
<br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF
<br />THE FACILITY AS PLANNED.
<br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS,
<br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO VERIFY ALL DIMENSIONS
<br />8. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR
<br />AND CONDITIONS IN THE FIELD. IF ANY DISCREPANCY OCCURS, THE
<br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION.
<br />CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT IN WRITING BEFORE
<br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY.
<br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE
<br />SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED TO PROVIDE
<br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS
<br />FIRE PROTECTION FOR THE SPECIFIED TENANT SPACE(S). THE
<br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY.
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP
<br />DRAWINGS AND HYDRAULIC CALCULATIONS TO THE ARCHITECT
<br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND
<br />FOR REVIEW AS WELL AS LOCAL JURISDICTION FOR PERMITTING.
<br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING
<br />NO WORK ON THE FIRE PROTECTION SYSTEM SHALL TAKE PLACE
<br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION.
<br />UNTIL THE APPROPRIATE PERMITS ARE OBTAINED BY THE FIRE
<br />PROTECTION SUB CONTRACTOR.
<br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL
<br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID.
<br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENTS
<br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO.
<br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND
<br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT)
<br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT
<br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN
<br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION
<br />APPROVAL FROM THE ARCHITECT AND OWNER.
<br />Legal Description
<br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25
<br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT
<br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE
<br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
<br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC
<br />RECORDS OF PASCO COUNTY, FLORIDA.
<br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS.
<br />Vicinity Map
<br />NTS
<br />Tenant Buildout for Space D3-D4
<br />Building D at Zephyr Commons
<br />7856 & 7860 Gall Blvd, Zephyrhills, FL
<br />SPACE D3-D4 (AREA OF INTERIOR WORK)
<br />Scope of Work
<br />1. THE SCOPE IS LIMITED TO TENANT SPACE D3-D4 IN BLDG D.
<br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES,
<br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES..
<br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER
<br />THAN BLDG D.
<br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE AEAS
<br />IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS.
<br />5. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE FINISHES, AWNINGS, STONE WORK, OR DECORATIVE
<br />TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS.
<br />6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE STOREFRONT SYSTEMS, DECORATIVE WINDOWS,
<br />FRONT STOREFRONT DOORS, OR REAR HOLLOW METAL DOORS ON ANY OF THE BUILDINGS.
<br />7. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS
<br />REQUIRED TO ADD AN EXHAUST FANS VENTS FOR THE NEW RESTROOMS. THE SCOPE DOES NOT
<br />7856 & 7860 GALL BLVD, ZEPHYRHILLS, FLORIDA
<br />INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS.
<br />8. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE
<br />NEW TENANT DEMISING WALLS. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED.
<br />9. THE SCOPE INCLUDES TWO NEW TENANT DEMISING WALLS.
<br />10. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING AND RIGID INSULATION ON THE INSIDE
<br />Code Information
<br />OF THE REAR MASONRY WALL INSIDE OF THE RESTROOM ONLY.
<br />11. THE SCOPE INCLUDES INSTALLING TWO NEW RESTROOMS PER ADA REQUIRMENTS.
<br />JURISDICTION AUTHORITY
<br />12. THE SCOPE INCLUDES INSTALLING NEW 2' x 4' ACT CEILINGS IN THE RESTROOMS AND THE MAIN ROOM OF
<br />THE TENANT SPACE.
<br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT
<br />5335 8TH STREET (813) 780-0020 - PHONE
<br />13. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF
<br />ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX
<br />DECK, OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE STRUCTURAL COMPONENTS OF
<br />THE MASONRY WALL. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK TO THE EXISTING LIGHT
<br />GAUGE FRAMING.
<br />ADOPTED CODES:
<br />14. THE SCOPE DOES NOT INCLUDE ANY SAW -CUTTING OF THE EXISTING FLOOR SLAB.
<br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS)
<br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS)
<br />15. THE SCOPE INCLUDES POURING A NEW SLAB IN THE AREA OF THE EXISTING SLAB LEAVEOUT AT THE
<br />(CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS)
<br />REAR OF TENANT SPACE D3-D4.
<br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS)
<br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009 AMENDMENTS)
<br />16. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE
<br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS)
<br />INCLUDES TURNING DOWN THE SPRINKLER HEADS AND MOVING THEM AS NEEDED TO FIT THE CEILING
<br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE)
<br />LAYOUT. THE SCOPE INCLUDES DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S
<br />FUEL/GAS: FLORIDA BUILDING CODE, FUEL/GAS - 2007 (W/ 2009 AMENDMENTS)
<br />SPECIALTY ENGINEER THROUGH HIS SHOP DRAWINGS.
<br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS)
<br />(CHAPTER 11- FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION).
<br />17. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE
<br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS)
<br />WATER SERVICE FOR THE RESTROOMS.
<br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION).
<br />18. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT
<br />IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY
<br />s.��� ni n��n rn��eT� rr+T�nw� T�
<br />QUA .... C ... .> _. _ . A _ . .. ..
<br />WORK TO ANY OF THE EXISTING CLEAN OUTS.
<br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE PIlease be advisedthis review of plans submitted is
<br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED cummy review to assist the contractor in compliance
<br />applicable fire e . This review is not intended
<br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) to be a final approval of the submitted plans. It is the
<br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES contractoes sole responsibility to ensure that the plans are in
<br />19. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF THE EXISTING ABOVE GROUND STUB IN
<br />FOR SPACE D3-D4.
<br />20. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO
<br />THE SANITARY OR VENT SYSTEMS.
<br />21. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE 2" COLD WATER MAIN, OR ANY OF
<br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE 1" COLD WATER BRANCH LINE OTHER
<br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER PIPING.
<br />22. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR
<br />FUTURE CONNECTION TO THE COLD WATER SYSTEM.
<br />23. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE.
<br />24. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE EXISTING 5 TON RTUS ABOVE SPACE D3-D4 OTHER
<br />THAN WHAT IS REQUIRED TO CONNECT NEW HVAC DUCTING. THE SCOPE DOES NOT INCLUDE ANY WORK
<br />FOR ANY OTHER RTUS OR ANY OF THE EXISTING CONDENSATE LINES.
<br />25. THE SCOPE INCLUDES PROVIDING FULL HVAC SYSTEM.
<br />26. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT,
<br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METER OR TENANT DISCONNECT.
<br />27. THE SCOPE INCLUDES PROVIDING A NEW 200 AMP TENANT PANEL CONNECTED TO THE EXISTING
<br />DISCONNECT VIA NEW WIRE PULLED THROUGH THE EXISTING EMPTY CONDUIT.
<br />28. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANEL.
<br />29. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOXES ON THE FRONT
<br />OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANEL.
<br />30. THE SCOPE INCLUDES WIRING THE EXISTING RTUS AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM
<br />TO THE TENANT PANEL.
<br />31. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE
<br />BUILDING OR THEIR WIRING.
<br />32. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURES ON
<br />THE REAR OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANEL VIA LIGHT SWITCHES.
<br />33. THE SCOPE INCLUDES NEW EXIT AND EMERGENCY LIGHTING THAT WILL BE WIRED TO THE NEW TENANT
<br />ELECTRICAL PANEL.
<br />34. THE SCOPE INCLUDES PROVIDING NEW 2' x 4' FLUORESCENT LIGHT FIXTURES WIRED TO THE TENANT
<br />ELECTRICAL PANEL.
<br />35. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING TELEPHONE STUB IN.
<br />36. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM AS
<br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE
<br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS.
<br />ACTUAL HEIGHT 35'-0" - ONE STORY Wnplete compliance Ah all applicable NFPA codes and lei.
<br />MAXIMUM AREA 12,500 SF local ortlinatIn the event that further examination or
<br />ACTUAL AREA 8,600 SF sile inspection revealsnon-compliance, it shall be
<br />the contrwWs sole responsibility, at their sole expense to
<br />�. r._.�.
<br />bring ftse areas
<br />in compliance. The City assumes no
<br />responsibility failure to be in compliance
<br />with all annhrat& A
<br />NOTE:
<br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00
<br />BLDG CATEGORY = II ENCLOSED. WIND EXPOSURE = B
<br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY
<br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS
<br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH
<br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA).
<br />Contact Information
<br />CLIENT:
<br />PRIMERICA GROUP ONE, INC.
<br />STRUCTURAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />3629 MADACA LANE
<br />ENGINEER:
<br />1925 PROSPECT AVE
<br />TAMPA, FL. 33618
<br />ORLANDO, FL 32814
<br />(813) 933-0629 PHONE
<br />(407) 661-9100 PHONE
<br />(813) 935-3420 FAX
<br />(407) 661-9101 FAX
<br />CONTACT: ADAM ROBINSON
<br />CONTACT: BRETT RYLANDS
<br />ARCHITECT:
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />MECHANICAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />1925 PROSPECT AVE
<br />ENGINEER:
<br />1925 PROSPECT AVE
<br />ORLANDO, FL 32814
<br />ORLANDO, FL 32814
<br />(407) 661-9100 PHONE
<br />(407) 661-9100 PHONE
<br />(407) 661-9101 FAX
<br />(407) 661-9101 FAX
<br />CONTACT: GABRIEL ROBERTSON
<br />CONTACT: JOE KEENE
<br />CIVIL
<br />AVID GROUP
<br />ELECTRICAL
<br />CUHACI & PETERSON, ARCHITECTS, LLC
<br />ENGINEER:
<br />8659 BAYPINE ROAD, STE 304
<br />ENGINEER:
<br />1925 PROSPECT AVE
<br />JACKSONVILLE, FLORIDA 32256
<br />ORLANDO, FL 32814
<br />(904) 737-4001 PHONE
<br />(407) 661-9100 PHONE
<br />(904) 252-7030 FAX
<br />(407) 661-9101 FAX
<br />CONTACT: BOB PIERRO
<br />CONTACT: TIM NASH
<br />SHEET NO. TITLE N SHEET PERMIT SET
<br />0 S 2009 08-13
<br />ARCHITECTURAL
<br />ALL WORI� SHALL COMPLY WITH ALA,
<br />PREVAILING CODES, FLORIDA BUILDIT^TO
<br />CODE, NATIONAL ELECTRIC CODE AN-)
<br />CITY OF ZEPI-I x'RHIL.LS ORDINANCES
<br />Drawing Index. ........... ........ ..... ... .....
<br />I�
<br />1
<br />^M
<br />v
<br />�
<br />J
<br />O
<br />O
<br />MM�
<br />�
<br />Cts
<br />I%t E
<br />�
<br />N8
<br />M
<br />U
<br />of
<br />z ,'
<br />o%
<br />o
<br />U o
<br />w
<br />a rn
<br />m�
<br />oCL
<br />� cp
<br />N
<br />p� T
<br />a.
<br />
|