Laserfiche WebLink
MII� <br />MiTek' <br />RE: TTH34-37 - <br />Site Information: <br />Customer Info: Starlight Homes <br />Lot/Block: 34-37 <br />Address: ., . <br />City: Xephyrhills <br />Lumber design values are in accordance with ANSI/TPI 1 section 6.3 <br />These truss designs rely on lumber values established by others. <br />Project Name: TTH34-37 Model: 4 plex <br />Subdivision: Tyson <br />State: Florida <br />MiTek USA, Inc. <br />16023 Swingley Ridge Rd <br />Chesterfield, MO 63017 <br />Name Address and License # of Structural Engineer of Record, If there is one, for the building. <br />Name: License #: <br />Address: <br />City: State: <br />General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special <br />Loading Conditions): <br />Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.6 <br />Wind Code: ASCE 7-16 Wind Speed: 150 mph <br />Roof Load: 37.0 psf Floor Load: N/A psf <br />This package includes 25 individual, Truss Design Drawings and 0 Additional Drawings. <br />With my seal affixed to this sheet, I hereby certify that 1 am the Truss Design Engineer and this index sheet <br />conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. <br />No. Seal# Truss Name Date <br />1 <br />T30641891 <br />C1A <br />5/25/23 <br />2 <br />T30641892 <br />C3A <br />5/25/23 <br />3 <br />T30641893 <br />CA <br />5/25/23 <br />4 <br />T30641894 <br />CJ3 <br />5/25/23 <br />5 <br />T30641895 <br />EJ5 <br />5/25/23 <br />6 <br />T30641896 <br />HJ5 <br />5/25/23 <br />7 <br />T30641897 <br />T01 <br />5/25/23 <br />8 <br />T30641898 <br />T02 <br />5/25/23 <br />9 <br />T30641899 <br />T03 <br />5/25/23 <br />10 <br />T30641900 <br />T04 <br />5/25/23 <br />11 <br />T30641901 <br />T04A <br />5/25/23 <br />12 <br />T30641902 <br />T05 <br />5/25/23 <br />13 <br />T30641903 <br />T05A <br />5/25/23 <br />14 <br />T30641904 <br />T06 <br />5/25/23 <br />No. Seal# Truss Name Date <br />15 <br />T30641905 <br />T06A <br />5/25/23 <br />16 <br />T30641906 <br />T07 <br />5/25/23 <br />17 <br />T30641907 <br />T07A <br />5/25/23 <br />18 <br />T30641908 <br />T09 <br />5/25/23 <br />19 <br />T30641909 <br />T10 <br />5/25/23 <br />20 <br />T30641910 <br />T10A <br />5/25/23 <br />21 <br />T30641911 <br />V03 <br />5/25/23 <br />22 <br />T30641912 <br />VO4 <br />5/25/23 <br />23 <br />T30641913 <br />V05 <br />5/25/23 <br />24 <br />T30641914 <br />V06 <br />5/25/23 <br />25 <br />T30641915 <br />V11 <br />5/25/23 <br />This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. <br />Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies <br />The truss drawing(s) referenced above have been prepared by <br />MiTek USA, Inc. under my direct supervision based on the parameters <br />provided by Builders FirstSource - Plant City. <br />Truss Design Engineer's Name: Velez, Joaquin <br />My license renewal date for the state of Florida is February 28, 2025. <br />IMPORTANT NOTE: The seal on these truss component designs is a certification <br />that the engineer named is licensed in the jurisdiction(s) identified and that the <br />designs comply with ANSI/TPI 1. These designs are based upon parameters <br />shown (e.g., loads, supports, dimensions, shapes and design codes), which were <br />given to MiTek or TRENCO. Any project specific information included is for MiTek's or <br />TRENCO's customers file reference purpose only, and was not taken into account in the <br />preparation of these designs. MiTek or TRENCO has not independently verified the <br />applicability of the design parameters or the designs for any particular building. Before use, <br />the building designer should verify applicability of design parameters and properly <br />incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. <br />PQU I N VFW -* J* <br />i <br />,�� ,O . • GE'N, <br />No 68182 <br />3 STATE OF :�� <br />•�� <br />�''��S 0 N A� .���� <br />Joaquin Velez PE No.68182 <br />MiTek Inc. DBA MiTek USA FL Cert 6634 <br />16023 Swingley Ridge Rd Chesterfield, MO 63017 <br />Date: <br />May 25,2023 <br />Velez, Joaquin 1 of 1 <br />