Laserfiche WebLink
S1- <br />INDEX <br />LOT 72 - PULSAR 'NR' <br />(� la 1 <br />9_PLEX BUILDING - A <br />GENERAL NOTES: <br />1. <br />CONTRACTORS SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT SITE BEFORE CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE BUILDER FOR <br />FL 0.1.10 <br />FL 1.11 <br />SLAB PLAN •N• <br />FLOOR PLAN'M <br />A 0.1.1 SLAB PERIMETER PLAN &PLEX <br />A 0.1.2 SLAB PERIMETER PLAN 9.PLE% <br />JUSTIFICATION AND/OR CORRECTION BEFORE CONTINUING WITH WORK. CONTRACTORS SHALL ASSUME RESPONSIBILITY FOR ERRORS THAT ARE NOT REPORTED TO <br />FL 1.11.1 <br />FLOOR PLAN OPTIONS <br />A 1.1 FIRST FLOOR PLAN 9-PLEX <br />THE BUILDER. <br />FL 4.11 <br />SECTIONS <br />A 1.1.1 FIRST FLOOR PLAN 9-PLEX 2, <br />ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, REGULATIONS, AND FHA/VA MPS. <br />FL 5.11 <br />FL 5.13.10 <br />ELEVROOF PLAN *N' <br />ROOF PLAN'N' <br />A 2.1 SECOND FLOOR PLAN &PLEX 3. <br />A 2. 1.1 SECOND FLOOR PLAN &PLEX <br />ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED. <br />FL 6.11 <br />UTILITY PLANS'N' <br />A 5.1 ELEVATIONS 9-PLEX 4. <br />ALL FOOTINGS TO BE BELOW FROST LINE (SEE LOCAL CODE) AND MUST REST ON UNDISTURBED SOIL CAPABLE OF HANDLING THE BUILDING LOAD. CONSULT LOCAL <br />A 5.1.1 ELEVATIONS &-PLEX <br />ENGINEER FOR PROPER FOOTING AND REINFORCING SIZES. <br />LOT 73 PULSAR 'LR' <br />A 5.1.2 ELEVATIONS &PLEX 5. <br />A5,1 <br />5.1.3 ELEVATIONS 9PLE% <br />CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS. <br />FL0.1.8 <br />SLAB PLAN .1 <br />A5.1.4 ELEVATIONS&PLEX 6. <br />IF BACKFILL EXCEEDS 4' AGAINST ANY FOUNDATION WALL, REINFORCE AS PER CODE. <br />FL 1.9 <br />FLOOR PLAN •L' <br />A 5.1.5 ROOF PLAN &PLEX 7• <br />ALL WOOD, CONCRETE, AND STEEL STRUCTURAL MEMBERS SHALL BE OF A GOOD GRADE AND QUALITY AND MEET ALL NATIONAL, STATE, AND LOCAL BUILDING CODES <br />FL 1.9.1 <br />FLOOR PLAN OPTIONS <br />A 5A.6 ROOF PLAN &PLEX <br />WHERE APPLICABLE. <br />FL 4.9 <br />FL 5.9 <br />SECTIONS <br />ELEVATIONS <br />DETAIL SHEETS 8. <br />ALL FOUNDATION AND STRUCTURAL MEMBERS SHOULD BE VERIFIED AND STAMPED BY AN ENGINEER IN THE STATE WHERE CONSTRUCTION IS OCCURRING DUE TO A <br />FL 5.13.8 <br />ROOF PLAN •L• <br />WIDE VARIANCE IN LOCAL CODES, SOIL BEARING CONDITIONS, FROST LINE DEPTH, GEOLOGICAL AND WEATHER CONDITIONS, ETC. <br />FL 6.9 <br />UTILITY PLANS'L' <br />D-1 DETAILS 9, <br />THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTING AND VERIFYING ALL STRUCTURAL DETAILS AND CONDITIONS TO MEET ALL LOCAL CODES TO INSURE A QUALITY <br />LOT 74 PULSAR 'KR' <br />0�2 DETAILS <br />DDETAILS <br />AND SAFE E. <br />or 10. <br />EXTERIOR FINISHES: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. -7TH EDITION (2020) RESIDENTIAL AND <br />FL 0, 1.7 <br />SLAB PLAN •K <br />0-5 DETAILS <br />STM C 1063. ALL LATH AND RESISTANT MATERIAL, EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1/2 INCH 11 GAUGE NAILS HAVING A 7/16 INCH <br />FL 1.0 <br />FL 1.8.1 <br />FLOOR PLAN'M <br />FLOOR PLAN OPTIONS <br />/ / <br />HEAD, OR 7/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. THICKNESS OF TEXTURED FINISH OVER FRAME <br />FL 48 <br />FL5.8 <br />SECTIONS <br />ELEVATIONS'K <br />�/ <br />APPLICATION TO FLORIDA BUILDING CODE 7TH EDITION 2020 RESIDENTIAL AND ASTM C 926. WEEP SCREEDS SHALL BE A MINIMUM OF NO. 26 GALVANIZED SHEET <br />( ) <br />GAUGE CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED <br />FL 5.13.7 <br />FL 6.8 <br />ROOF PLANK' <br />UTIUTY PLANS•K <br />,/ <br />AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE <br />THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. STUCCO APPLICATION AND CURING PER <br />LOT 75 <br />- PULSAR '.I' <br />l(n <br />c <br />FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL OR IN ACCORDANCE WITH ASTM C 926. <br />?� 11. <br />CHAPTER AND SECTIONS REFER TO F.B.C.R. - 7TH EDITION (2020). NOTE: ANY DIMENSION AND/OR CALLOUTS WITHIN THIS SET OF DRAWINGS REFERENCING LUMBER <br />FL 0.1.6 <br />FL 1.7 <br />SLAB PLANT <br />FLOOR PLAN',r <br />/ <br />SIZES OR WALL THICKNESS ARE TO BE CONSIDERED "NOMINAL DIMENSIONS". ALL DIMENSIONS ARE TO ROUGH FRAMING UNLESS OTHERWISE NOTED. <br />THE TO THAT ELECTRICAL F.B.C.R. <br />FL 1.7.1 <br />FL 4.7 <br />FLOOR PLAN OPTIONS <br />SECTIONS <br />✓ 12. <br />IT IS RESPONSIBILITY OF THE LICENSED ELECTRICIAN ENSURE ALL WORK IS IN FULL COMPLIANCE WITH N.F.P.A. 70, N.E.C. 2017, - <br />7TH EDITION (2020), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. <br />FL 5.7 <br />ELEVATIONS'' <br />13. <br />EGRESS: EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS TO EXTERIOR THROUGH A DOOR THE WINDOW <br />FL 5.13.6 <br />ROOF PLAN'J' <br />MUST HAVE A MAXIMUM CLEAR OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR ROOM. <br />FL 6.7 <br />UTIUTY PLANS•J• <br />�• <br />14. <br />ASPHALT SHINGLES (IF APPLICABLE): <br />LOT 76 - PULSAR 'M' <br />WIND RESISTANCE OF ASPHALT SHINGLES - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905.2.6.1. <br />ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER FOR ROOF SLOPES FROM TWO <br />FL 0.1.9 <br />SLAB PLAN 'M' <br />'j <br />UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING <br />FL 1.1.10 <br />FL 10.1 <br />FLOOR PLAN' <br />FLOOR PLAN OPTIONS <br />(//� <br />WITH ASTM D 226, TYPE I OR TYPE II, ASTM D 4869, TYPE II OR TYPE IV OR ASTM D 6757 IS REQUIRED IN ACCORDANCE WITH SECTION R905.11. FOR ROOF SLOPES <br />FL 4.10 <br />sEcrlorvs <br />FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE II, ASTM D 4869, TYPE <br />FL5.10 <br />EIFVAT IONS•M' <br />IV OR ASTM D 6757 IS REQUIRED IN ACCORDANCE WITH SECTION R905.11. <br />FL 5.13.9 <br />ROOF PLAN •M' <br />15. <br />TERMITE TREATMENT WILL BE DONE USING SENTRICON TERMITE BAITING STATIONS AND AND SHALL BE IN ACCORDANCE WITH FBC(R), SECTION R318 AND ALL <br />FL 6.10 <br />UTILITY PLANS•M' <br />RELATED SUB SECTIONS. <br />LOT 77 - PULSAR 'AR' <br />16. <br />UTILITY EASEMENT: USE OF THE SUBDIVISION FOR UTILITIES INCLUDING BUT NOT LIMITED TO UTILITY EASEMENTS AS SHOWN ON PLAT SHALL BE IN ACCORDANCE <br />WITH THE APPLICABLE PROVISIONS OF THIS DECLARATION. THE DECLARANT AND ITS AFFILIATES AND ITS AND THEIR DESIGNEES SHALL HAVE A PERPETUAL <br />FL0.1 <br />SLABPLAN•A• <br />EASEMENT OVER, UPON AND UNDER THE LOTS (INCLUDING BUT NOT LIMITED TO THE UNITS) AND THE COMMON AREAS (EXCLUDING THE CONSERVATION AREAS) FOR <br />FL 1.1 <br />F11.1 <br />L , <br />FLOOR PLAN'OPTIONS <br />FLOOR PLAN O <br />THE INSTALLATION, OPERATION AND MAINTENANCE OF UTILITY IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO ELECTRIC LINES, WATER AND SEWER PIPES, <br />FL 4.1 <br />SECTIONS <br />TELEPHONE LINES, COMMUNITY AND / OR CABLE TELEVISION AND SECURITY AND OTHER COMMUNICATION LINES, EQUIPMENT AND MATERIALS AND OTHER SIMILAR <br />FL 5.1 <br />ELEVATIONS'A• <br />TELEVISION, RADIO AND SECURITY CABLES AND ALL FUTURE TECHNOLOGICAL ADVANCES NOT NOW KNOWN), FOR SERVICE TO THE LOTS AND OTHER PORTIONS <br />FL <br />ROOF PUN •A' <br />OF THE SUBDIVISION, PROVIDED THAT NO OWNER'S NORMAL RESIDENTIAL USE OF SUCH OWNER'S UNIT SHALL BE INTERFERED WITH IN ANY UNREASONABLE <br />6.13 <br />FL J <br />UTILITY PUNs'A' <br />MANNER. <br />LOT 78 - PULSAR 'M' <br />17. <br />EXTERIOR WALL ENVELOPE: BUILDER IS RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF SECTION 107.2.4 OF THE F.B.C. BUILDING BY PROVIDING <br />ALL DETAILS LISTED UNDER THIS SECTION INCLUDING BUT NOT LIMITED TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL SUPPORTING <br />FL 0'1.9 <br />SLAB PLAN'M' <br />DOCUMENTATION TO ENSURE THE WEATHER RESISTANCE OF THE EXTERIOR WALL ENVELOPE IS MAINTAINED. <br />FLI.10 <br />FL 1.10.1 <br />FLOOR PUN OPTIONS <br />FLOOR PLAN O <br />18. <br />STUCCO CONTROL JOINTS TO BE INSTALLED PER ASTM C 1063-06 7.11.4.1 THRU 7.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 S.F. AND <br />( <br />FL4.10 <br />SECTIONS <br />DELINEATE AREAS NOT MORE THAN 100 S.F. FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT. IN EITHER DIRECTION <br />FL5.10 <br />ELEVATIONS'M• <br />OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO 1. A CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE <br />FL .13.9 <br />ROOF PLAN'M• <br />EXPANSION JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS. <br />FL 6.10 <br />UTILITY PLANS'M' <br />19. <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR <br />LOT 79 - PULSAR 'BR' <br />DIRECTIONS, AND AROUND ROOF OPENINGS. <br />APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY <br />FL 0.1.1 <br />SUB PUN'B' <br />OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SH ALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FL 1.2.1 1.2 <br />FL <br />FLOOR PLAN O <br />IT <br />FLOOR PLAN OPTIONS <br />FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER R703.8. <br />FLa.z <br />sEcr^lo�Ny' <br />I SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION <br />ELEV , ,;WORK <br />SHALL COMPLY WITH PRE <br />ONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />FFL L 5.23.1 <br />FL 6.2 <br />u-T'O any FLORIDA BUILDING (BODE, 21. <br />ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT <br />w.+ <br />Fi <br />LOT 80 - &81Aii, M <br />^•s +� <br />ELECTRIC CODE, <br />THE TIME OF APPLICATION FOR PERMIT. <br />MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, <br />FL0.1.11 <br />SLAB P}�' �� ri t <br />% -'EP �IYRHILLS <br />OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL <br />FL 1.12 <br />FLOORi'Lt,111i7i TWE <br />b "y <br />WORKING SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. <br />FL 1.12.1 <br />FLOGr �,�Ly1�.. <br />GT,S ARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED A MIN. #26 <br />FL a.1z <br />secn�'`rh fl' <br />E <br />lJC3E ) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />FL5.12 <br />ELEVATIONS •o <br />F U DATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 MM) ABOVE THE FINISHED GRADE AND SHALL ALSO <br />FL 5. 13.11 <br />FL 6.12 <br />ROOF PLAN r' <br />LANS <br />UTILITY PLANS'O' <br />CONFORM TO THE MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />p L F'1 A"i <br />C)ATE <br />DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING <br />v �r`j\{ <br />REVIEW <br />� � ONENTWILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />'�L9 f !! 1 ICABLE PROVISIONS OF SECTIONS M1411.3. <br />ii <br />G I AA5 .e - <br />PLAN 1. M r:' � <br />THIS PROJECT MUST COMPLY WITH: 2020 FLORIDA BUILDING CODE RESID TIAL - 7TH EDITION, FLORIDA FIRE <br />PREVENTION CODE 7TH EDITION (THIS INCLUDES THE FLORIDA SPECIFIC EDITION OF 2018 NFPA 1 UNIFORM FIRE CODE, <br />AND 2018 NFPA 101 LIFE SAFETY CODE). NFPA 10, 2018 EDITION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS. NFPA <br />13D, 2016 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS IN ONE -AND TWO-FAMILY DWELLINGS <br />AND MANUFACTURED HOMES. NFPA 70, 2017 EDITION, NATIONAL ELECTRICAL CODE. NFPA 72, 2016 EDITION, NATIONAL <br />FIRE ALARM AND SIGNALING CODE. NFPA 90A, 2018 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING <br />AND VENTILATING SYSTEMS. 2020 FLORIDA BUILDING CODE ENERGY CONSERVATION, 7TH EDITION. 2020 FLORIDA <br />BUILDING CODE MECHANICAL, 7TH EDITION. 2020 FLORIDA BUIDLING CODE PLUMBING, 7TH EDITION. 2020 FLORIDA <br />BUILDING CODE FUEL GAS, 7TH EDITION. <br />OCCUPANCY: RESIDENTIAL - R3 <br />b 3 <br />bIV <br />b2u <br />TYSON <br />9-PLEX - <br />A LOTS 72-80 <br />PLAN 1386 PULSAR SF <br />TOTAL BUILDING SF <br />NAME <br />AREA <br />NAME <br />AREA <br />FIRST FLOOR <br />1588 SF <br />FIRST FLOOR <br />5469 SF <br />SECOND FLOOR <br />1798 SF <br />SECOND FLOOR <br />7343 SF <br />HEATED 1386 SF <br />HEATED 12812 SF <br />GARAGE <br />226 SF <br />GARAGE <br />1991 SF <br />PORCH <br />132 SF <br />PORCH <br />1281 SF <br />PATIO /GOV. PORCH <br />80 SF <br />PATIO /COV. PORCH <br />720 SF <br />UNHEATED 336 SF <br />UNHEATED 2992 SF <br />CMw <br />J F <br />O <br />Q <br />W <br />ISSUE DATE: <br />09.22.2023 FOR <br />REVIEW <br />REVISIONS: <br />These drawings are the <br />property of Starlight <br />Homes and are not to be <br />utilized for construction, or <br />copied in part or in whole <br />without permission from <br />the builder. 0 2023 <br />Starlight Homes <br />LAST REVISION <br />c Li <br />U <br />� <br />C <br />L <br />o <br />C <br />W <br />N <br />w <br />X <br />W ~ <br />U.1 <br />N <br />aCn <br />LLI <br />� O <br />U <br />Q <br />SHEET NO: <br />T-1 <br />Fr <br />O <br />U_ <br />