Laserfiche WebLink
r <br />2 <br />12 <br />E <br />0 <br />r <br />!2 <br />15 <br />18 <br />Le <br />14 <br />0 <br />0 <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1.1 FIRST FLOOR PLAN <br />1.2 SECOND FLOOR PLAN <br />2.1 EXTERIOR ELEVATIONS - FRONT & LEFT <br />2.2 EXTERIOR ELEVATIONS - REAR & RIGHT <br />3 ELECTRICAL PLAN <br />4 ROOF PLAN <br />5 FOUNDATION PLAN <br />6.1 FLOOR FRAMING PLAN <br />6.2 ROOF FRAMING PLAN <br />ABBREVIATIONS 7 LINTEL PLAN & DETAILS <br />AB or A.B. Anchor Bolt FIX or FXD Fixed RA or R/A or R.A. Return Air SN STRUCTURAL NOTES <br />ABV or Abv. Above FLR or Fir. Floor RAD or Red. Radius SN1 DETAILS <br />AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAG or Rag. Return Air Grill S3 DETAILS <br />ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry REC or Rec. Recessed S4 DETAILS <br />AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace RECEPT Receptacle <br />AHU or A.H.U. Air Handler Unit FR DR French Door REF or Ref. Refrigerator S5 <br />DETAILS <br />ALT or ALT. Alternate FRT Front REINF Reinforcing <br />S6M DETAILS <br />BC Base Cabinet FT or Ft. Foot/ Feet REQD or Req'd. Required <br />BF Bifold Door FTG or Ftg. Footing RM or Rm. Room ST STAIR DETAILS <br />BK SH or Bk Sh BookShelf FXD GIL Fixed Glass RND or Rnd. Round <br />SS RETROFIT DETAILS <br />BILK or BILK. Block GALV or GaIv. Galvanized RO or R.O. Rough Opening <br />BLW or BLW. Below GC or G.C. General Contractor RS, R/S, R/SH or R&S Rod and Shed D 1 SECTIONS & DETAILS <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter SC Solid Core <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector ------ D2 SECTIONS & DETAILS <br />BP or B.P. Bypass(door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door WP WATERPROOFING DETAILS <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves <br />C Carpet HC Hollow Core SHT Sheet PA1.0 PRODUCT APPROVAL NUMBERS <br />CAB Cabinet HOR or Hdr. Header SHWR or Shwr. Shower PA1.1 PRODUCT APPROVAL NUMBERS <br />CIR or Cir. Circle HGT or Hgt. Height St. or S.L. Side Lights <br />CJ or C/J Control Joint HH or H.H. Hand Held (plumbing faucet) SPECS or SPECS. Specifications PA1.2 PRODUCT APPROVAL NUMBERS <br />CLG or CIg. Ceiling HORIZ Horizontal SPF or S.P.F. Spruce Pine Fir SH1.0 HURRICANE SHUTTER PRODUCT APPROVAL <br />CMU Concrete Masonry Unit HS Hard Surface (flooring) SQ FT or SF or S.F. Square Foot (feet) <br />COFF or Coff. Coffered or Tray Ceiling ILO In Lieu Of SQ or Sq. Square SH1.1 HURRICANE SHUTTER PRODUCT APPROVAL <br />COL or Col. Column INSUL or Insul. Insulation STO Storage HURRICANE SHUTTER PRODUCT APPROVAL <br />Community INT or Int. Interior SW or S.W. Shear Wall SH1.2 <br />COMM or Comm. <br />COMP or Comp. Compressor KNVALL or KIWall Kneewall SYP or S,Y.P. Southern Yellow Pine SH1.3 HURRICANE SHUTTER PRODUCT APPROVAL <br />CONN or CONN. Connection KS or K.S. Knee Space TB Towel Bar 0 0 <br />CONT or Cont. Continuous LAUN or Laun. Laundry TEMP or Temp. Tempered SH1.4 HURRICANE SHUTTER PRODUCT APPROVAL <br />— — — — — — — — — — --- <br />CSMT Casement LAV or Lev. Lavatory THIKN or Thik'n. Thicken SH1.5 HURRICANE SHUTTER PRODUCT APPROVAL <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. TOB or T.O.B. Top of Block <br />D or D. Dryer LL Lintel Length TOM or T.O.M. Top of Masonry <br />DB Door Bell LT Laundry Tub TOP or T.O.P. Top of Plate <br />DBIL or Dbl. Double MAS or Mas. Masonry TP Toilet Paper Holder FL ---- OM- =[]E1E1L] <br />DCF Decorative Cementitious Finish MAX or Max Maximum TR Towel Ring U <br />Typical — �] Ll <br />DEC or Dec. Decorative MC Medicine Cabinet TRANS VvDW or Trans. Transom Window <br />DIED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TYP or Typ. <br />DIA or Dia. Diameter MGT Management (room) LIC or u.c. Under Counter <br />DISP or Disp. Disposal MIN or Min Minimum UCL Under Cabinet Lighting FBI I L7— 71 L] L� L7 <br />DIST or Dist. Distance MIR or Mir. Mirror LINO or U.N.O. Unless Noted Otherwise <br />DMF Decorative Masonry Finish MIL or M.L. Microlam V or v. Valve (shower or tub/shower) <br />DS or D.S. Drawer Stack MONO or Mono Monolithic VB Vanity Base <br />DTL Detail MW or MICRO or Micro. Microwave VERT or Vert. Vertical <br />DV or D.V. DryerVent NTS or N.T.S. Not to Scale VL or V.L. Versalam <br />DVP or D.V.P, Diverter Valve (plumbing) OE or O.E. Owner's Entry VTR or VTE Vent through Roof / Exterior <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening Worw Washer MEAN ROOF 15 FT. HIGH TYPICAL <br />EA or Ea. Each OPT or Opt. Optional W/ or w/ With FOR SINGLE STORY HOMES <br />ELEC or Elec. Electrical PC Pull Chain WA or W.A. Wedge Anchor <br />ELEV or Elev. Elevation PIED or Ped. Pedestal WCorW/CorW.C. Water Closet (toilet) <br />EQ Equal PH Phone WD or Wd Wood MEAN ROOF 30 FT. HIGH TYPICAL <br />EW or E.W. Each Way PKT or Plit. Pocket (Door) WDVV HDR or WDW. HDR. Window Header FOR 2 STORY HOMES <br />EXP or Exp. Expansion PL or P.L. Parallam WH or W. H. Water Heater <br />EXT or Ext. Exterior PLF Pounds per linear foot WC or W.I.C. Walk-in Closet THIS DRAWING AND DESIGN IS VALID <br />FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf VN or W.M. Wall Mounted (plumbing fixture) FOR 12 MONTHS AFTER THE DATE IT <br />FDN or Fdn. Foundation PLT HT or Pit. Ht Plate Height WP Water Proof(ing) IS SIGNED AND SEALED OR WHILE <br />FFB Finsh Floor Break PSF Pounds per square foot WS Water Softener CURRENT CODE IS VALID <br />FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WWF Welded Wire Fabric (Mesh) CODE REFERENCES ARE SUMMARIES <br />FIN Finished PW or P.W. Pre -wire <br />FIN FLR or FF or Fin. Fir. Finished Floor PWDR or Pwd. Powder Room REV. 06.23.22 OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />PLAN REVISIONS COMPLETE CODE INFORMATION. <br />DATE VERSION DESCRIPTION Notice to Builder & All Subcontractors <br />F It is the intent of Designer/Engineer listed in the titleblock of these <br />08/23/12 1.00 NEW BASE PLAN documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />07/30/15 1.1 2015 NEW CODE UPDATE the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />05/09/18 2.0 FBC 2017 CODE UPDATES construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />12/19/20 3.0 FBC 2020 CODE UPDATES considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and EOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and EOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/tioi .,w r <br />are necessary for the future life of this home. Care nrit., en <br />to check windows and doors for caulking, remove le0v <br />debris off roofs, make sure that water flow is away fror 3, <br />house and have your home repainted every 3 - 5 yeArS P act <br />2074 the coatings. The designer and engineer of record ipre ;t <br />responsible for the upkeep of the home and will not t IP <br />liable for instances that may occur over the normal li* <br />p <br />home without proper maintenance. <br />C= <br />LL-) <br />cc C-1 C�4 <br />cm <br />LA- <br />C= <br />C14 <br />W <br />E <br />0 <br />tj <br />C-4 <br />CP <br />2W <br />C3 <br />W <br />CD <br />V/V 61" <br />(y? <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings oomply with the 2020 Florida Building Code - <br />Residential 7th Edition, Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />as <br />Cc> <br />0 L-L <br />- <br />C� U- u!J <br />C14 C, CL LU <br />C CL. - — (D <br />Z <br />a13 C') 'r <br />Z 0 <br />2 41 <br />W r— <br />T Z <br />co ui <br />Lr) L) <br />04 co <br />Z 0 (5 000 <br />c') V <br />C14 Cl) <br />OD <br />Go <br />< <br />E3 <br />(/)L/) 2f <br />(1) CD <br />4—J 11-1 u. <br />Fu LU C <br />C� A <br />L) --- I <br />0 6 <br />C3 <br />V) C14 <br />Ln <br />U <br />A� LL' <br />< '0 <br />LL- <br />cd E <br />C�. <br />Z <br /><� <br />Z 0 <br />E 8 <br />so <br />ZIS <br />E <br />'W <br />CA) <br />v <br />Wo <br />Z <br />0 <br />0, <br />—17 <br />cy) <br />M <br />CN <br />(0 Ul) <br />Ir— <br />:3 'r- <br />LO <br />00"'. <br />< <br />Cr C" <br />F- <br />L0 <br />0 <br />CQ <br />C) <br />M C5 <br />It) <br />LO N <br />S -- <br />< <br />7— <br />4i <br />E <br />ZI ce) CV) <br />E CN i?5 <br />0 <br />M <br />Z <br />E r— <br />M <br />CL <br />M <br />JOB <br />NO: 23-06107 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />