My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37709 Dusty Saddle Ln
Zephyrhills
>
Building Department
>
Building Plans
>
37709 Dusty Saddle Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:25:07 PM
Creation date
2/19/2025 8:45:33 AM
Metadata
Fields
Template:
Building Plans
Street #
37709
Location
Dusty Saddle Ln
Contractor
AMH Development
Building Plans - Permit #
8076
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
370-Rooseveit Cmu <br />Garaize RiLyht - Elevation - I3 <br />SHEET MEX <br />NUMBER: <br />SHEET NAME: <br />NUMBER: <br />SHEET NAME: <br />CS <br />COVER SWEET <br />C5-3 <br />SQUARE FOOTAGE CALCULATIONS <br />A-32 <br />MI5C DETAILS <br />F-ID <br />FOUNDATION - SLAB PLAN <br />A-33 <br />MI5C DETAILS <br />A-3.4 <br />MIS- DETAILS <br />A -ID <br />FIRST FLOOR PLAN <br />A-2.0 <br />SECOND FLOOR PLAN <br />A-3.10 <br />FRONT/REAR ELEVATIONS I/ROOF PLAN <br />A-3.11 <br />SIDE ELEVATIONS I <br />A-4.0 <br />BUILDING SECTIONS <br />E-10 <br />ELECTRICAL PLANS - FIRST t SECOND FLOOR <br />P-0.1 <br />PLUMBING R15ER DIAGRAM <br />GENERAL NOTES <br />THE STANDARD GENERAL SPECIFICATIONS FOR AMERICAN HOMES 4 RENT d AMIH <br />DEVELCI—MENT SHALL GOVERN EXCEPT AS MODIFIED 4 SUPPLEMENTED BY THESE <br />PLANS. <br />THESE PLANS HAVE BEEN DESIGNED TO MEET THE REQUIREMENT5 OF: <br />2023 FLORIDA BUILDING CODE, RESIDENTIAL, SO, EDITION <br />OCCUPANCY: SINGLE FAMILY RESIDENTIAL <br />CEILING CONSTRUCTION: <br />I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA <br />Y T SS THAN 1/2 INCH (127 —) Y A APPLIED 1 THE A B NO LE GYPSUM BOARD LED O E GARAGE <br />SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL <br />HABITABLE ROOTS ABOVE BY NOT LESS THAN 5/B INCH (15.5 —) TYPE "X" GYPSUT•I <br />BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, <br />THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT <br />LESS THAN 1/2 INCH (R.1 —)GYPSUM BOARD OR EQUIVALENT. <br />EXTERIOR FINISHES: <br />THI004ES9 OF TEXTURED FINISH OVER FRAME APPLICATION SHALL BE PER THE <br />CURRENT APPROVED BUILDING CODE AND A57M CW&, INSTALLATION OF EXTERIOR <br />LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER THE CURRENT <br />APPROVED BUILDING CODE AND 45TM C 1063. <br />EGRE55: <br />I_ EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF <br />THERE IS NO ACCESS TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST HAVE A <br />MAXIMUM OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR <br />ROOT. <br />2. IN DWELLING UNITS WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED <br />MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE <br />LOWEST PART OF THE CLEAR OPENING OF THE WNDOW SHALL BE A MINIMUM OF 24 <br />INCHES ABOVE THE FINISHED FLOOR. OPERABLE SECTIONS OF WINDOWS SHALL NOT <br />PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4" SPHERE WHERE SUCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER THE CURRENT <br />APPROVED BUILDING CODE. <br />FLASHING: <br />I. FLASHING SHALL BE N57ALLED AT WALL AND ROOF INTERSECTIONS. DECK AND <br />WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION. <br />AND AROUND ROOF OPENINGS, <br />2. APPROVED CORRO5ICN-RESIS7ANT FLASHING SHALL BE APPLIED SHINGLE <br />FASHION IN SUCH A MANNER 49 TO PREVENT ENTRY OF WATER INTO THE WALL <br />CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING <br />COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR <br />WALL FINISH. APPROVED CORROSION-RE915TANT FLASHING SHALL BE INSTALLED AT <br />ALL REQUIRED LOCATIONS PER THE CURRENT APPROVED BUILDING CODE. <br />WINDOW INSTALLATION: <br />I, WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE <br />MIANUFACTURER5 WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION <br />INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW <br />FLOOD ZONE REQUIREMENTS: <br />I. PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION <br />L <br />ENERGY REQUIREMENT SCHEDULE <br />EXTERIOR WALLS (FRN'E) <br />R-l3 <br />EXTERIOR WALLS(BLOCK) <br />41 FOIL <br />ATTIC CEIL►A3 <br />R.3o <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. <br />�26 GAUGE (048 —) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL <br />HAVE NO OPENINGS INTO THE GARAGE. <br />A. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE <br />BATH AREAS: <br />INSTALLED ABOVE THE BASE FLOOD ELEVATION AND SHALL ALSO CO -FORM TO 7HE <br />I. R45TALL 2x4 BLOCKING AT TOILET PAPER AND TOWEL BAR LOCATIONS, SEE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />DETAILS. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDEN51NG APPLIANCES SHALL BE <br />KITCHENS: <br />PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE 70 ANY BUILDING <br />IeN . BTALL 2X& BLOCKING AT SIB" AFF. ON CENTER FOR UPPER CABINET <br />COMPONENT WILL OCCUR 45 A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN <br />INSTALLATION. <br />PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />APPLICABLE PROVISIONS OF SECTIONS 11I4113. <br />TUB AND OILER AREAS: <br />T CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD <br />ALLOWED) IN COMPLIANCE WITH AST" C12W, C1325, OR CIT15 AND INSTALLED WITH -5 <br />x 1-1/14' DAGGERZ PHILIPS WAFER HEAD CEMENT BOARD SELF DRILL SCREWS W/ <br />NG COATISHALL BE USED A5 BACKERS FOR WALL 71 LE IN TUB AND SHOWER AREAS, <br />AND WALL PANELS N SHOWER AREAS. <br />TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, <br />INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED <br />TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF <br />THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF <br />COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED <br />PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE <br />BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF <br />SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES." <br />MECHANICAL AND HVAG: <br />I, ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE <br />FURNISHED BY THE MECHANICAL ENGINEER AS AN ATTACHMENT TO THIS PLAN SET <br />47 THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCES SHALL BE ACCE5815LE FOR INSPECTION, SERVICE, <br />REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER <br />APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE <br />BEING INSPECTED, SERVICED. REPAIRED, OR REPLACED. A LEVEL WORKING SPACE <br />AT LEAST 30 INCHES (162 —) DEEP AND 30 INCHES (162 —) WIDE SHALL BE <br />PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. <br />EXHAUST FANS AND VENTING: <br />I. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST <br />SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED <br />N70 AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE <br />RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE <br />EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND <br />TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER <br />AREAS INSIDE THE BUILDING. <br />3. DUCT LENGTH. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE <br />DETERMINED BY ONE OF THE METHODS SPECIFIED IN SECTIONS M502 451 THROUGH <br />MI502.45.3. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET FROM <br />THE CONNECTION 70 THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET <br />TERMINAL. THE MAXIMUM LENGTH OF THE DUCT &HALL BE REDUCED 25 FEET (162 mm) <br />FOR EACH 45 DEGREE (0.15 WAD) BEND AND 5 FEET (B24 —) FOR EACH 90 <br />DEGREE NA, RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT <br />INCLUDE THE TRANSITION DUCT, EXCEPTION - WHERE A CLOTHES DRYER BOOSTER <br />FAN IS IN5TALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM <br />LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT. SHALL BE <br />PERMITTED 70 BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED <br />AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER 16 LOCATED. <br />A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE <br />EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THIS DRYER <br />EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." <br />4. PROVIDE BACK DRAFT DAMPERS AT INTAKE AND EXHAUST LOCATIONS A9 <br />REQUIRED BY THE CURRENT APPROVED BUILDING CODE. <br />ISSUED: 2/27/2024 <br />VERSION: 5.0 <br />SQUARE FOOTAGE <br />AIM AMBET MANAGEMBiT SM FT. <br />HEATED AREA <br />Sq. Ft <br />MAIN LEVEL <br />1102 <br />SECOND LEVEL <br />12T5 <br />TOTAL AHIR 8O. FT. (BYMCMQ <br />I 2V7 <br />METHODOLOGY: ANSI ZT615- 9 <br />The IoW area calculated hom ft-Midlio- olside 11 hrnq, inddiq opbo W fwahed bammnt opWm as <br />shown. This erae excludes stairwell at highest Iml abm grade, garage, covered pabo/porchm. <br />,HE = �. EC7.R1C <br />')POINAl\ICEc✓r or)Mi, r <br />r� <br />�cViEiN DATE <br />vri ~ <br />(-- r <br />P,A ZPHIN Arvijj y��� S <br />V <br />DO NTI NIGLE T4W DWACA <br />'BIFT 9"W. ONEVATICN On <br />CL?Mt*ZT R AV MIT RIM <br />culm COMTgCTm Tww <br />M&WA DO NOr QWM <br />bFECW WCRYtVH FOR ANr <br />Sm%cf A neon no BE <br />FROPU®m' sapm OF <br />WC,Ml YM Da00WAN-1 <br />OPO4 C 6 ORWATIW ETC) <br />eum TIM Da/1sm Ar0 TN <br />IMl CoIYECTED. TIE <br />CWMAVOR AMFE$ TIE <br />0"O"L" TO NETT ALL <br />OF LOCAL sa-G <br />W-Wo r TO COFLT YIN ST, <br />w> <br />A <br />LLI <br />� u <br />x <br />as <br />0 <br />y <br />z <br />n <br />O� <br />N <br />O <br />r� <br />L7 <br />R <br />v� <br />q <br />O <br />O <br />uC-)a <br />IL <br />W <br />y <br />8 <br />a <br />N <br />0 <br />� <br />cM <br />pApqq <br />E-1 <br />1 <br />L J <br />-!I 1! <br />VERSION: 5.0 <br />COVER SHEET <br />IIIIIIIIIIIIIIIa <br />C <br />
The URL can be used to link to this page
Your browser does not support the video tag.