Laserfiche WebLink
� <br />� <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />CS <br />COVER SHEET <br />1.1 <br />FIRST FLOOR PLAN <br />1.2 <br />SECOND FLOOR PLAN <br />2 <br />EXTERIOR ELEVATIONS <br />ELECTRICAL PLAN <br />3 <br />4 <br />ROOF PLAN <br />FOUNDATION PLAN <br />5 <br />6.1 <br />FLOOR FRAMING PLAN <br />6.2 <br />ROOF FRAMING PLA <br />LINTEL PLAN & DETAILS <br />7 <br />SN <br />STRUCTURAL NOTES <br />DETAILS <br />SN1 <br />ABBREVIATIONS <br />S3 <br />DETAILS <br />DETAILS <br />S4 <br />AB or A B. <br />Anchor Bolt <br />FIX or FXD Fixed <br />PWDR or Pwd. <br />Powder Room <br />S5 <br />DETAILS <br />ABV or Abv- Above <br />FLR or Fir. Floor <br />RA or R/A or R.A. Return Air <br />AC or AIC <br />ADJ or ADJ. <br />Air -Conditioner <br />Adjustable <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />RAD or Rad. <br />RAG or Rag. <br />Radius <br />Return Air Grill <br />S6 <br />DETAILS <br />AFF or A F.F. <br />Above Finished Floor <br />FP or F.P. Fireplace <br />REC or Rec. <br />Recessed <br />ST <br />STAIR DETAILS <br />AHU orA.H.U. <br />ALT or ALT. <br />Air Handier Unit <br />Alternate <br />FR DR French Door <br />FRT Front <br />RECEPT <br />REF or Ref. <br />Receptacle <br />Refrigerator <br />SS <br />RETROFIT DETAILS <br />BC <br />Base Cabinet <br />FT or Ft Foot( Feet <br />REINIF <br />Reinforcing <br />D 1 <br />SECTIONS & DETAILS <br />D2 <br />SECTIONS & DETAILS <br />BK SH or Bk Sh BookShelf <br />FXD GL Fixed Glass <br />RM or Rm. Room <br />BLIK or BILK <br />Block <br />GALV or GaIv. Galvanized <br />RND or Rnd. <br />Round <br />WP <br />WATERPROOFING DETAILS <br />BLWorBLW. <br />Below <br />GC or G.C. General Contractor <br />RO or R.O. <br />Rough Opening <br />PA1.0 <br />PRODUCTAPPROVALNUMBERS <br />BM or Bm. Beam <br />GFI or G.F.I. Ground Fault Interrupter <br />IRS, R/S, R/SH or R&S Rod and Shelf <br />BOT or Bot. <br />BP or B.P. <br />Bottom <br />Bypass (door) <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />SD or SD. <br />SGD <br />Smoke Detector <br />Sliding Glass Door <br />PA1.1 <br />PRODUCTAPPROVALNUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />BRG or BRG. Bearing <br />HB Hose Bibb <br />SH or Sh. Shelves <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CIR or Cir. <br />CJ or C/J <br />Circle <br />Control Joint <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />SL or S.L. <br />SPECS or SPECS. <br />Side Lights <br />Specifications <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.2 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CLG or Cig. Ceiling <br />HS Hard Surface (flooring) <br />SPF or S.P.F. Spruce Pine Fir <br />CMU <br />COFF or Coff. <br />Concrete Masonry Unit <br />Coffered or Tray Ceiling <br />ILO In Lieu Of <br />INSUL or Insul. Insulation <br />SQ FT or SF or S.F. <br />SO or Sq. <br />Square Foot (feet) <br />Square <br />-T <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />SH1.4 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COL or Col. Column <br />INT or Int. Interior <br />STO Storage <br />COMM or Comm. <br />COMP or Comp. <br />Community <br />Compressor <br />KNVALL or K/Wall Kneewall <br />KS or K.S. Knee Space <br />SW or S.W. <br />SYP or SY.P. <br />Shear Wall <br />Southern Yellow Pine <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CONT or Cont. <br />CT or C.T. <br />Continuous <br />Ceramic Tile <br />LAV or Lay. Lavatory <br />LF or L.F. Linear Ft. <br />TEMP or Temp. <br />THIKN or Thik'n. <br />Tempered <br />Thicken <br />D or D. <br />Dryer <br />LL Lintel Length <br />TOB or T.O.B. <br />Top of Block <br />El El El El El El El <br />DB <br />Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBIL or Dbl. Double <br />MAS or Mas. Masonry <br />TOP or T.O.P. Top of Plate <br />DCF <br />Decorative Cementitious <br />Finish <br />MAX or Max Maximum <br />TP <br />Toilet Paper Holder <br />El [::]E:11::][:] [::][:::]L— <br />00 <br />DEC or Dec. <br />DIED or Ded. <br />Decorative <br />Dedicated (outlet) <br />MC Medicine Cabinet <br />MFR or Mfr. Manufacturer <br />TR <br />TRANS WDW or Trans. <br />Towel Ring <br />Transom Window <br />Diameter <br />MGT Management (room) <br />TYP or Typ. <br />Typical <br />— <br />DISP or Disp. <br />Disposal <br />MIN or Min Minimum <br />LIC or u.c. <br />Under Counter <br />DIST or Dist Distance <br />MIR or Mir. Mirror <br />UCL Under Cabinet Lighting <br />DMF <br />Decorative Masonry Finish <br />ML or M.L. Microlam <br />LINO or U.N.O. <br />Unless Noted Otherwise <br />DS or D.S. <br />Drawer Stack <br />MONO or Mono Monolithic <br />Vorv. <br />Valve (shower or tub/shower) <br />DTIL <br />Detail <br />MW or MICRO or Micro. Microwave <br />VB <br />Vanity Base <br />DV or D.V. <br />DryerVent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />DVP or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL or V.L. Versalarn <br />DW or D.W. <br />Dishwasher <br />OPNG or Opn'g. Opening <br />VTR or VTE <br />Vent through Roof / Exterior <br />FOR SINGLE STORY HOMES <br />EA or Ea. <br />Each <br />OPT or Opt. Optional <br />Worw <br />Washer <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />ELEC or Elec. Electrical <br />PC Pull Chain <br />Worw/ With <br />ELEV or Elev. <br />EQ <br />Elevation <br />Equal <br />PED or Ped. Pedestal <br />PH Phone <br />WA or W.A. <br />WC or W/C or W,C. <br />Wedge Anchor <br />Water Closet (toilet) <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />EW or E.W. Each Way <br />PKT or Pkt. Pocket (Door) <br />WD or Wd Wood <br />EXP or Exp. <br />EXT or Ext. <br />FBC <br />FDN or Fdn. <br />Expansion <br />Exterior <br />Florida Building Code <br />Foundation <br />PL or P.L. Parallarn <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />PLT HT or Pit Ht. Ptate Height <br />WDW HDR or WOW. HDR. <br />WH or W.H. <br />WIC or W.I.C. <br />WNI or W.M. <br />Window Header <br />Water Heater <br />Walk-in Closet <br />Wall Mounted (plumbing ftre) <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />FG Fiberoass (Shower Pan) <br />PSF Pounds per square foot <br />WP Water Proof(ing) <br />FIN <br />FIN FLR or FF or Fin. Fir. <br />Finished <br />Finished Floor <br />PT or P.T. Pressure Treated <br />PW or P.W. Pre -wire <br />WS <br />VWVF <br />Water Softener <br />Welded Wre Fabric (Mesh) <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />04/25/12 1.00 NEW BASE PLAN <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />06/25/12 2.00 GRADE BEAM FOUNDATION <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />08/26/15 3.00 2015 NEW CODE UPDATE <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />03/06/18 4.00 FBC 2017 CODE UPDATES & MODEL UPDATES <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Deasigner/Engineer. <br />05/30/19 <br />4.01 <br />MOVE KITCHEN DOWN, ADD 6" WALL AT REF. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />12/19/20 5.00 FBC 2020 CODE UPDATE <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />7M r1Q <br />JX F1 <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and EOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other per![ or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and EOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check winclows and doors for caulking, remove leaves and <br />1525 <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. I <br />Co <br />7Nllftfl <br />IV <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />Engineers signature and seal. <br />W Co <br />13 r-cacl 0 P 9 <br />L, <br />WC4GXO-i <br />M-J <br />ILr- <br />Z 2 Z W Ln <br />RL <br />a 04 Ci ( < <br />CL <br />U) <br />LU <br />Z <br />Z <br />CL <br />CD <br />mi <br />CD <br />od <br />CID <br />C14 <br />a) <br />04 <br />JOB <br />NO 22-02369 <br />sc4e�' <br />AS NOTED_ <br />SHEET NO. <br />C S <br />