My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35965 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35965 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:15:37 PM
Creation date
2/19/2025 10:47:22 AM
Metadata
Fields
Template:
Building Plans
Street #
35965
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20740
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:35�w <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1.1 FIRST FLOOR PLAN <br />1.2 SECOND FLOOR PLAN <br />2 INTERIOR ELEVATIONS <br />3.1 EXTERIOR ELEVATIONS <br />3.2 EXTERIOR ELEVATIONS <br />F1 FOAM DETAIL <br />4.1 FIRST FLOOR ELECTRICAL PLAN <br />4.2 SECOND FLOOR ELECTRICAL PLAN <br />5.1 ROOF PLAN <br />6.1 FOUNDATION PLAN <br />7.1 FLOOR FRAMING PLAN <br />ABBREVIATIONS 7.2 ROOF FRAMING PLAN <br />8 LINTEL DETAILS <br />AB or A, B. Anchor Bolt FIN FLR or FF or Fin. Fir. Finished Floor PWDR or Pwd. Powder Room <br />ABV or Abv. <br />Above FIX or FXD Fixed RA or R/A or R.A. Return Air SN STRUCTURAL NOTES <br />AC or A/C Air -Conditioner FLR or Fir. Floor RAG or Rag. Return Air Grill <br />SN1 DETAILS <br />ADJ or ADJ. Adjustable FLR SYS or Fir Sys Floor System RAD or Rad. Radius <br />AFF or A.F.F. <br />Above Finished Floor FOM or F. 0. M. Face Of Masonry REC or Rec. Recessed <br />S3M DETAILS <br />AH U or A. H. U. Air Handler Unit FP or F.P. Fireplace RECEIPT Receptacle <br />ALT or ALT. Alternate FR DR <br />French Door REF or Ref. Refrigerator F"� S4 DETAILS <br />BC Base Cabinet FRT Front REINF Reinforcing <br />BF Bifold Door FT or Ft Foot/ Feet REQD or Req'd. Required S5 DETAILS <br />BK SH or Bk Sh BookShelf FTG or Ftg. Footing RM or Rm. Room S6M DETAILS <br />BLKorBLK. Block GALV or GaIv. Galvanized RND or Rnd. Round ST DETAILS <br />BLW or BLW. Below GC or G.C. General Contractor RO or R.O. Rough Opening <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter RS or R/S or R&S Rod and Shelf SS RETROFIT DETAILS <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector <br />BP or B.P. Bypass(door) GYP BD or Gyp. Bd. Gypsum Board SQ FT or SF or S.F. Square Foot (feet) D 1 SECTIONS & DETAILS <br />BRG or BRG. Bearing HB Hose Bibb SGD Sliding Glass Door D2 SECTIONS & DETAILS <br />C Carpet HDR or Hdr. Header SH or Sh. Shelves <br />CAB Cabinet HGT or Hgt. Height SHWIR or Shwr. Shower VVP WATERPROOFING DETAILS <br />CIR or Cir. Circle HH or H.H. Hand Held (plumbing faucet) SHT Sheet PA1.0 PRODUCT APPROVAL NUMBERS <br />CJ or CIJ Control Joint HORIZ Horizontal SLorS.L. Side Lights <br />CLG or CIg. Ceiling HS Hard Surface (flooring) SPF or S.P,F. Spruce Pine Fir PA1. 1 PRODUCTAPPROVALNUMBERS <br />CMU Concrete Masonry Unit ILO In Lieu Of SPECS or SPECS. Specifications PA1.2 PRODUCTAPPROVALNUMBERS <br />COFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SQ or Sq. Square <br />COL or Col. Column INT or Int. Interior STO Storage PA1.3 PRODUCTAPPROVALNUMBERS <br />COMM or Comm. Community K/WALL or K/Wall Kneewall SW or S.W. Shear Wall <br />COMP or Comp. Compressor KS or K.S. Knee Space SYP or S.Y.P. Southern Yellow Pine <br />CONN or CONN. Connection LAUN or Laun. Laundry TB Towel Bar <br />CONT or Cont. Continuous LAV or Lay. Lavatory TEMP or Temp. Tempered <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. THIKN or Thik'n. Thicken <br />D or D. Dryer LL Lintel Length TOB or T.O.B. Top of Block <br />DB Door Bell LT Laundry Tub TOMorT.O.M. Top of Masonry <br />DBL or Dbl. Double MGT Management (room) TOP or T.O.P, Top of Plate <br />DCF Decorative Cementitious Finish MAS or Mas. Masonry TP Toilet Paper Holder <br />DEC or Dec. Decorative MAX or Max Maximum TR Towel Ring <br />DIED or Ded. Dedicated (outlet) Mc Medicine Cabinet TRANS WDW or Trans. Transom Window <br />TYP or Typ. Typical ] �F 1 -1 <br />DISP or Disp. Disposal MW or MICRO or Micro. Microwave LIC or u.c. Under Counter I T- I <br />DIA or Dia. Diameter MFR or Mfr. Manufacturer 1� I F= 11 MN <br />DIST or Dist. Distance MIN or Min Minimum UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish MIR or Mir. Mirror UNO or U.N.0, Unless Noted Otherwise <br />v, DS or D.S. Drawer Stack ML or M.L. Microlam V or v. Valve (shower or tub/shower) <br />-3r <br />7 DTL Detail MONO or Mono Monolithic VB Vanity Base <br />0 <br />-0 <br />5� DV or D.V. DryerVent NTS or N.T.S. Not to Scale VERT or Vert. Vertical <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. <br />Owner's Entry VL or V. L. Versaiam <br />Cn <br />�:: DW or D.W. Dishwasher OPING or Opn'g. Opening VTR Vent through Roof <br />8 EA or Ea. Each OPT or Opt. Optional Worw Washer <br />EW or E.W. Each Way PC Pull Chain W/ or w/ With <br />LO ELEC or Elec. Electrical FED or Ped. Pedestal WC or W/C or W.C, Water Closet (toilet) <br />E LEV or Elev. Elevation PH Phone WA or W.A. Wedge Anchor <br />EQ Equal PKT or Pkt. Pocket (Door) WD or Wd Wood <br />C�4 <br />EXT or Ext. Exterior PIL or P.L. Parallarn VVDW HDR or WDW. HDR. Window Header <br />EXP or Exp. Expansion PLF Pounds per linear foot WH or W. H. Water Heater <br />00 <br />7, FBC Florida Building Code PLT HT or Pit. Ht Plate Height WC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation PUNT SHLF or Pit. Sh. Plant Shelf WMorW.M. Wall Mounted (plumbing fixture) <br />FXD GIL Fixed Glass PSF Pounds per square foot WIP Water Proof(ing) <br />FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WS Water Softener <br />Pi <br />0 FIN Finished PW or P.W. Pre -wire VVWF Welded Wre Fabric (Mesh) <br />E! <br />CD <br />REVISIONS <br />LO <br />C) <br />'5- 06-09-17 1.0 NEW BASE PLAN <br />c, 12-28-17 2.0 2017 FBC CODE UPDATE <br />'V <br />-1 01-04-18 3.0 ADDED HVAC IN LAUNDRY <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. FOR SINGLE STORY HOMES <br />�2 <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />04-13-18 4.1 REV. DOOR TO WC IN M. BATH FOR 2 STORY HOMES <br />CL <br />E <br />THIS DRAWING AND DESIGN IS VALID <br />E 08-18-18 4.2 ADD ATTIC ACCESS TO 1 ST FLR. FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />co CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />IP Aix COMPLETE CODE INFORMATION. <br />IL I I <br />0 <br />C-) Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer pirior to <br />C�. construction. All construction MUST be in accordance to the <br />Z� ALL WORK VAL Li W1*4 �SIIMWLINO information found in these documents. Any questions regarding <br />11300158 FLGROA i6c t W .9 JAN 2 4 2019 the information found in these plans should be directed to our <br />NATIONAL EM,Tr�i,"- ('ML'1 Office at (407) 880-2333 immediately. No backcharges will be <br />AN0 THE CITY OF 4�Piri VAHILLS 3246 considered for reimbursement by the Designer/Engineer without <br />Pill AW IWA444-letde4 /Z/Z advanced notification and approval by the Designer/Engineer. <br />%9iNANGES Payments will be made in accordance to the terms of the <br />agreement. <br />(D V <br />C'3 <br />c:1 <br />' <br />7-143 <br />__J <br />E3 <br />U) <br />V, (D <br />Q) <br />C-/J <br />(1) <br />4--J LU <br />(a <br />Z <br />0 LU <br />V) <br />ME <br />E <br />0 <br />0 <br />04 <br />LU <br />E <br />(D <br />'"-9 <br />aj <br />win <br />-0 C-) <br />"' c4 <br />o <br />= LL 00 <br />—5 , co <br />0 <br />C" <br />0 izz, <br />U) 0� C> <br />0 7;�' <br />< <br />A <br />C . S D - C <br />4't <br />Z Lu C5 :4, Z" <br />LU g.. g <br />LU r-L <br />U3 <br />Z 0 <br />A <br />is <br />E <br />Z <br />LL <br />UJ <br />DS <br />,)0 -kNPqQM '�'p <br />�kk-) y V P4 <br />S E <br />< <br />0 <br />'0' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and sea]. <br />L E 014' N A R <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 Z <br />0 <br />Z <br />UJ <br />U 80-) <br />U <br />=) Z Z <br />U Col Z' <br />0, �2 <br />8 Lu <br />(g) <br />Z <br />LLJ <br />0 <br />0 <br />U <br />= L <br />Z <br />Z <br />-0 <br />�%� <br />C/) <br />0 <br />Q) <br />mi;r <br />LLJ <br />5 <br />Z <br />< <br />�' w <br />U <br />r'J <br />0 <br />0 <br />9 g <br />9R6 <br />2<: OU <br />U, 0< <br />U <br />r'J <br />1P <br />Z <br />LU <Z <br />< <br />Ln <br />Z <br />Z <br />11714 <br />r-4 <br />CY2 �j <br />U-J <br />Ln <br />Lij <br />LZL' <br />< <br />< <br />wo <br />W Z <br />r-4 <br />110 <br />'I- <br />Z <br />tu <br />< 0 <br />U') 0 <br />Z <br />&2 <br />0 <br />�0 <br />06 <br />Z <br />:5 <br />LU <br />� U) <br />� Z <br />< ... <br />2: <br />rn <br />T--i <br />a_ <br />SCALE AS NOTED <br />DATE 10/2/2018 <br />TECH: MJAMES <br />VERSION NO '412 <br />SHEET NO. <br />C S <br />J <br />1.1 -7, -TT— lobIM 'III Ill "lal 11 1 <br />A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.