OWNER:
<br />Florida Cancer Specialists
<br />Contact: Susan Parker
<br />38010 Medical Center Avenue
<br />Zephyrhills, FL 33450
<br />Tel: (813) 783-1676
<br />Fax: (813) 783-1929
<br />ARCHITECT:
<br />SaltCo, LLC
<br />2650 Bahia Vista Street - Suite 302
<br />Sarasota, Florida 34239
<br />Tel: (941) 312-5523
<br />Fax: (941) 312-5529
<br /># AA-26001479
<br />MECHANICAL, ELECTRICAL , PLUMBING, &
<br />SMITH, SECKMAN, & REID, INC.
<br />301 North Cattlemen Road
<br />Suite 300
<br />Sarasota, Florida 34232
<br />Tel: (941) 907-7750
<br />Fax: (941) 907-7751
<br />GENERAL NOTES
<br />IT IS THE RESPONSIBILITY OF EACH SUBCONTRACTOR TO REVIEW ALL
<br />DRAWINGS, PROJECT MANUAL, ADDENDA, ETC. TO ASSURE
<br />COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO
<br />REVIEW ALL CONTRACT DOCUMENTS FOR APPLICABLE ITEMS OF WORK
<br />SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING ALL
<br />WORK REQUIRED
<br />1. EXISTING CONDITIONS - THE EXISTING CONDITIONS SHOWN ON
<br />THESE DRAWINGS ARE BASED ON INFORMATION PROVIDED TO
<br />THE ARCHITECT. THE CONTRACTOR SHALL VERIFY ALL
<br />EXISTING CONDITIONS ON THE JOB SITE, AND NOTIFY THE
<br />ARCHITECT OF DEVIATIONS FROM THESE DRAWINGS PRIOR TO
<br />FABRICATION AND INSTALLATION OF THE WORK.
<br />2. DRAWINGS - THESE DRAWINGS SHALL NOT BE SCALED. REFER TO
<br />DIMENSIONS INDICATED, ACTUAL SIZES OF CONSTRUCTION
<br />ITEMS OR OTHER METHOD OF LOCATING CONSTRUCTION. WHERE
<br />NO DIMENSION OR METHOD OF DETERMINING A LOCATION IS
<br />GIVEN, VERIFY CORRECT LOCATION WITH ARCHITECT PRIOR TO
<br />INSTALLATION.
<br />3. DIMENSIONS - DIMENSIONS ON PLANS ARE FROM COLUMN GRID
<br />LINES, FACE OF MASONRY, FACE OF EXISTING WALL OR FINISHED
<br />SURFACE OF FRAMED WALL, UNLESS NOTED OTHERWISE.
<br />DIMENSIONS INDICATED AS CLEAR SHALL BE A MINIMUM
<br />DIMENSION, FACE TO FACE OF FINISH MATERIALS.
<br />4. PRECAUTIONS - IF UNFORESEEN CONDITIONS ARE DISCOVERED
<br />WHICH COULD CAUSE ADVERSE EFFECTS UPON THE STRUCTURE
<br />OR ITS OCCUPANTS, REPORT ANY SUCH CONDITION
<br />IMMEDIATELY TO THE ARCHITECT. TAKE PRECAUTIONS TO
<br />PROPERLY SUPPORT THE STRUCTURE. THE CONTRACTOR SHALL
<br />REPORT ALL HAZARDOUS MATERIALS DISCOVERED TO OWNER,
<br />ARCHITECT AND AUTHORITIES HAVING JURISDICTION.
<br />5. PLUMBING, MECHANICAL, ELECTRICAL, FIRE PROTECT.,
<br />STRUCTURAL, CIVIL- BRING TO THE ATTENTION OF THE
<br />ARCHITECT ALL CONFLICTS WITHIN THE WORK.
<br />6. EXIT ACCESS - MAINTAIN FREE, SAFE, AND APPROVED MEANS OF
<br />EGRESS IN AND OUT OF PROJECT LOCATION IN ACCORDANCE
<br />WITH REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES.
<br />7. NEW / EXISTING - NEW WORK SHALL ALIGN WITH AND MATCH
<br />EXISTING WORK EXCEPT WHERE OTHERWISE DIMENSIONED OR
<br />DETAILED
<br />8. COORDINATION / ADJUSTMENT - CONTRACTOR SHALL
<br />COORDINATE ALL NEW WORK WITH EXISTING CONDITIONS AND
<br />ADJUST AS REQUIRED UPON ARCHITECT'S REVIEW.
<br />BASIC CRITERIA
<br />CONSTRUCTION:
<br />OCCUPANCY:
<br />AREA MAP
<br />EOUIPMENT REPLACEMENT
<br />38010 MEDICAL CENTER AVENUETC
<br />ZEPHYRHILLS, FL 33450 SITE � a
<br />LOCATION
<br />AREA OF WORK
<br />r. . . . . . . . . . . E
<br />IV W
<br />F.
<br />Lei
<br />DRAWING SYMBOLS
<br />WALL SECTION DETAIL
<br />_4(X NUMBER
<br />AXXX WALL SECTION DRAWING
<br />NUMBER
<br />X DETAIL NUMBER
<br />/ 1 AXXX DRAWING NUMBER
<br />I
<br />A
<br />COLUMN GRID REFERENCE
<br />NUMBER/LETTER
<br />+
<br />1
<br />PARTITION SECTION
<br />X DETAIL NUMBER
<br />OIL LEVEL LINE ELEVATION
<br />XXX X'-X' REFERENCE POINT
<br />REVISION NUMBER
<br />AREA OF REVISION
<br />A 707 SHEET NUMBER
<br />3� DIRECTION OF VIEW
<br />INTERIOR ELEVATION
<br />NUMBER
<br />NFPA TYPE II (0,0,0), NON-SPRINKLERED
<br />F.B.C. TYPE II-B, NON-SPRINKLERED
<br />NFPA 101: CH. 39: EXISTING BUSINESS
<br />F.B.C.: BUSINESS - GROUP B
<br />BUILDING AREA TOTAL: f 41770 SF
<br />INTERIOR RENOVATED AREA TOTAL: ± 835 SF
<br />TOTAL NEW AREA: f 0 SF
<br />NO NEW AREA WILL BE ADDED AS A PART OF THIS PROJECT.
<br />APPLICABLE CODES:
<br />Florida Building Code, Building, 2014 Edition
<br />NFPA 1, The Florida Fire Prevention Code, Fifth Edition, 2012
<br />NFPA 101 Life Safety Code, 2012 Edition
<br />Florida Building Code, Plumbing, 2014 Edition
<br />Florida Building Code, Mechanical, 2014 Edition
<br />Florida Building Code, Fuel Gas, 2014 Edition
<br />Florida Building Code, Existing Building, 2014 Edition
<br />NFPA 70 - 2011 - National Electric Code (NEC)
<br />NFPA 72 - 2010 - National Fire Alarm Code
<br />NFPA 99 - 2012 - Standard for Health Care Facility
<br />Florida Accessibility Code, 2014 Edition
<br />Guidelines for Design and Construction of Health Care Facilities, 2010 Edition
<br />SALT 0, LLC
<br />COMMISSION N0. 71604
<br />DATE: JULY 1, 2016
<br />STANDARD ABBREVIATIONS
<br />A
<br />A
<br />A.B.
<br />AIR
<br />ANCHOR BOLT
<br />F
<br />F.A.
<br />F.A.C.
<br />FIRE ALARM
<br />FIRE APPARATUS CABINET
<br />P
<br />PART'N.
<br />PARTITION
<br />A/C
<br />AIR CONDITIONING
<br />F.B.
<br />FACE BRICK
<br />P.C.
<br />PRECAST CONCRETE
<br />ACCESS.
<br />ACCESSORIES
<br />F.D.
<br />FLOOR DRAIN
<br />P.C.F.
<br />PER CUBIC FOOT
<br />ADH
<br />ADHESIVE
<br />FDTN.
<br />FOUNDATION
<br />PERF.
<br />P.L.
<br />PERFORATED
<br />ADJ.
<br />ADJUSTABLE
<br />F.E.C.
<br />FIRE EXTINGUISHER CABINET
<br />PLAS.
<br />PROPERTY LINE
<br />PLASTER
<br />A.F.F.
<br />ABOVE FINISHED FLOOR
<br />F.F.L.
<br />FINISH FLOOR LINE
<br />P.L.F.
<br />PER LINEAR FOOT
<br />AHU
<br />AIR HANDLING UNIT
<br />F.H.C.
<br />FIRE HOSE CABINET
<br />PLT.
<br />PLATE
<br />ALT.
<br />ALTERNATE
<br />FIN.
<br />FINISH
<br />PLYWD.
<br />PLYWOOD
<br />ALUM.
<br />ALUMINUM
<br />FLASH.
<br />FLASHING
<br />P&M
<br />PATCH & MATCH
<br />ANOD.
<br />ANODIZED
<br />FLUOR.
<br />FLUORESCENT
<br />PREP.
<br />PREPARATION
<br />APPROX.
<br />APPROXIMATE
<br />FLR.
<br />FLOOR
<br />PT.
<br />POINT
<br />ARCH.
<br />ARCHITECT OR ARCHITECTURAL
<br />FLRG.
<br />FLOORING
<br />P.T.
<br />PRESSURE TREATED
<br />ASB
<br />ASBESTOS
<br />F.R.
<br />FLOOR RECEPTOR
<br />PTD.
<br />PAINTED
<br />ASPH.
<br />ASPHALT
<br />FT.
<br />FOOT OR FEET
<br />PVMT
<br />PAVEMENT
<br />AUTO
<br />AUTOMATIC
<br />FTG.
<br />FOOTING
<br />PUB.
<br />PUBLIC
<br />B
<br />BD.
<br />BOARD
<br />FURR.
<br />FURRING
<br />BET.
<br />BETWEEN
<br />FUT.
<br />FUTURE
<br />Q
<br />Q.T.
<br />QUARRY TILE
<br />BITUM.
<br />BITUMINOUS
<br />G
<br />G.
<br />GAS
<br />Q.T.B.
<br />QUARRY TILE BASE
<br />BLDG.
<br />BUILDING
<br />GA.
<br />GAUGE (GAGE)
<br />QTY•
<br />QUANTITY
<br />BILK.
<br />BLOCK
<br />G.C.
<br />GENERAL CONTRACTOR
<br />R
<br />R.
<br />RISERS
<br />BLKG.
<br />BLOCKING
<br />G. 1.
<br />GALVANIZED IRON
<br />R.A.
<br />RETURN AIR
<br />B.M.
<br />BENCHMARK
<br />GL.
<br />GLASS
<br />RAID.
<br />RADIUS
<br />BM.
<br />BEAM
<br />GR.
<br />GRADE
<br />R.D.
<br />ROOF DRAIN
<br />BOT.
<br />BOTTOM
<br />G.W.B.
<br />GYPSUM WALL BOARD
<br />BRG.
<br />BEARING
<br />RECEP.
<br />RECEPTOR
<br />BSMT.
<br />BASEMENT
<br />REF.
<br />REFERENCE
<br />B.W.
<br />BOTH WAYS
<br />REFR.
<br />REFRIGERATOR
<br />BNCH.
<br />BENCH
<br />H
<br />H.B.
<br />HOSE BIB
<br />REINF.
<br />REINFORCING
<br />H.BD.
<br />HARDBOARD
<br />REL.
<br />RELOCATED
<br />C
<br />C.A.
<br />COMPRESSED AIR
<br />H.C.
<br />HOLLOW CORE
<br />REQ'D.
<br />REQUIRED
<br />CAB
<br />CABINET
<br />H/C
<br />HANDICAPPED
<br />RESIL.
<br />RESILIENT
<br />CEM.
<br />CEMENT
<br />HDW.
<br />HARDWARE
<br />RET.
<br />RETURN
<br />C.F.I.
<br />CONTRACTOR FURNISHED AND INSTALLED
<br />HDWD.
<br />HARDWOOD
<br />REV.
<br />REVISE
<br />C.F.T.
<br />CERAMIC FLOOR TILE
<br />HGT.
<br />HEIGHT
<br />RFG.
<br />ROOFING
<br />C.G.
<br />CORNER GUARD
<br />H.M.
<br />HOLLOW METAL
<br />RGTR.
<br />REGISTER
<br />CHKD. PL.
<br />CHECKERED PLATE
<br />HORIZ.
<br />HORIZONTAL
<br />R.H.
<br />RIGHT HAND
<br />C.I.
<br />CAST IRON
<br />HR.
<br />HOUR
<br />R.L.
<br />RAIN LEADER
<br />C.I.P.
<br />CAST IN PLACE
<br />H.R.
<br />HANDRAIL
<br />RM.
<br />ROOM
<br />C.J.
<br />CONSTRUCTION JOINT
<br />H.W.
<br />HOT WATER
<br />R.O.
<br />ROUGH OPENING
<br />C.L.L.
<br />CONTRACT LIMIT LINES
<br />HVAC
<br />HEAT/VENTILATING/AIR CONDITIONING
<br />R.O.W.
<br />RIGHT OF WAY
<br />CLG.
<br />CEILING
<br />I
<br />ICIN.
<br />INCINERATOR
<br />RUB.
<br />RUBBER
<br />CLO
<br />CLOSET
<br />I.D.
<br />INSIDE DIAMETER
<br />CLR.
<br />CLEAR
<br />INS
<br />INSTRUMENT
<br />S
<br />S.
<br />SINK
<br />C.M.
<br />CONSTRUCTION MANAGER
<br />IN L.
<br />INSULATION
<br />S.C.
<br />SOLID CORE
<br />C.M.U.
<br />CONCRETE MASONRY UNIT
<br />INT.
<br />INTERIOR
<br />CNT.J.
<br />CONTROL JOINT
<br />.0
<br />I.
<br />INVERT
<br />S.D.
<br />STORM DRAIN
<br />CASED OPENING
<br />I.P.S.C.O.
<br />P.
<br />IRON PIPE SIZE
<br />SECT.
<br />SECTION
<br />COL.
<br />COLUMN
<br />SH.
<br />SHELF
<br />CONC.
<br />CONCRETE
<br />J
<br />J.C.
<br />JANITORS CLOSET
<br />SHLVG.
<br />SHELVING
<br />CONN.
<br />CONNECTION
<br />JST.
<br />JOIST
<br />SHTG.
<br />SHEATHING
<br />CONST.
<br />CONSTRUCTION
<br />JT.
<br />JOINT
<br />SHT.
<br />SHEET
<br />CONT.
<br />CONTINUOUS
<br />K
<br />SHWR.
<br />SHOWER
<br />CRS.
<br />COURSES (BRICK OR BLOCK)
<br />K. 0.
<br />KNOCK -OUT
<br />SIM.
<br />SIMILAR
<br />CSWK.
<br />CASEWORK
<br />K.O.P.
<br />KNOCK -OUT PANEL
<br />SPECS.
<br />SPECIFICATIONS
<br />C.T.
<br />CERAMIC TILE
<br />SPKR.
<br />SPEAKER
<br />C.T.B.
<br />CERAMIC TILE BASE
<br />L
<br />LAB.
<br />LABORATORY
<br />SQ.
<br />SQUARE
<br />C.W.
<br />COLD WATER
<br />LAM
<br />LAMINATE
<br />S.ST.
<br />STAINLESS STEEL
<br />C.W.G.
<br />CLEAR WIRE GLASS
<br />LAV.
<br />LAVATORY
<br />STA.
<br />STATION
<br />L.C.
<br />LAUNDRY CHUTE
<br />STD.
<br />STANDARD
<br />D
<br />D.A.
<br />DOUBLE ACTING
<br />L.H.
<br />LEFT HAND
<br />ST'L.
<br />STEEL
<br />D.BD.
<br />DRAIN BOARD
<br />LKRS.
<br />LOCKERS
<br />STOR.
<br />STORAGE
<br />DBL.
<br />DOUBLE
<br />L.L.
<br />LIVE LOAD
<br />STRUCT.
<br />STRUCTURAL
<br />DEPT.
<br />DEPARTMENT
<br />L. PT.
<br />LOW POINT
<br />SYS.
<br />SYSTEM
<br />DET.
<br />DETAIL
<br />DEM.
<br />DEMOLITION
<br />LVR.
<br />LOUVER
<br />T
<br />D.F.
<br />DRINKING FOUNTAIN
<br />L.V.W.
<br />LEAD VIEW WINDOW
<br />T.
<br />TREAD
<br />DIA.
<br />DIAMETER
<br />M
<br />TECH.
<br />TECHNICIANS
<br />DIAG.
<br />DIAGONAL
<br />M.
<br />METER
<br />TEL.
<br />TELEPHONE
<br />DIM.
<br />DIMENSION
<br />MAT'L.
<br />MATERIAL
<br />THK.
<br />THICK
<br />DN.
<br />DOWN
<br />MAX.
<br />MAXIMUM
<br />T&G
<br />TONGUE & GROOVE
<br />D.O.
<br />DOOR OPENING
<br />M
<br />MECH.
<br />MECHANICAL
<br />TK.BD.
<br />TACK BOARD
<br />D.S.
<br />DOWN SPOUT
<br />MED.
<br />MEDIUM
<br />TOIL.
<br />TOILET
<br />DWG.
<br />DRAWING
<br />MFG.
<br />MANUFACTURER
<br />T.O.S.
<br />TOP OF SLAB
<br />D.WT.
<br />DUMB WAITER
<br />M.H.
<br />MANHOLE
<br />T.O.W.
<br />TOP OF WALL
<br />MIN.
<br />MINIMUM
<br />T.P.
<br />TOILET PARTITION
<br />E
<br />E.
<br />EAST
<br />MISC.
<br />MISCELLANEOUS
<br />TYP.
<br />TYPICAL
<br />EA.
<br />EACH
<br />MLDG.
<br />MOULDING
<br />E.H.B.
<br />ELECTRIC HOLD BACK
<br />M.M.
<br />MILLIMETER
<br />U
<br />UNF.
<br />UNFINISHED
<br />EF
<br />EXHAUST FAN
<br />M.O.
<br />MASONRY OPENING
<br />U.O.N.
<br />UNLESS OTHERWISE NOTED
<br />ELEC.
<br />ELECTRICAL
<br />M.T.
<br />METAL THRESHOLD
<br />URIN.
<br />URINAL
<br />ELEV.
<br />ELEVATION
<br />MTD.
<br />MOUNTED
<br />UTIL.
<br />UTILITY
<br />EMERG.
<br />EMERGENCY
<br />MTL.
<br />METAL
<br />V
<br />E.P.
<br />ELECTRICAL PANEL BOARD
<br />MULL.
<br />MULLION
<br />V.
<br />VACUUM
<br />EQ.
<br />EQUAL
<br />MWK.
<br />MILLWORK
<br />VERT.
<br />VERTICAL
<br />EQUIP.
<br />EQUIPMENT
<br />VEST.
<br />VESTIBULE
<br />EXIST.
<br />EXISTING
<br />N
<br />N.
<br />N.A.
<br />NITROGEN OR NORTH
<br />NOT APPLICABLE
<br />V.I.F.
<br />VERIFY IN FIELD
<br />EXH.
<br />EXHAUST
<br />NAT.
<br />NATURAL
<br />EXP'D.
<br />EXPOSED
<br />NOM.
<br />NOMINAL
<br />W
<br />W.
<br />WEST
<br />EXP.JT.
<br />EXPANSION JOINT
<br />N.T.S.
<br />NOT TO SCALE
<br />W/
<br />WITH
<br />EXT.
<br />EXTERIOR
<br />O
<br />WD.
<br />WOOD
<br />E.T.R.
<br />EXISTING TO REMAIN
<br />0.
<br />OXYGEN
<br />W.G.
<br />WIRE GLASS
<br />O.A.
<br />OVERALL
<br />ON CENTER
<br />W.H.O.C.
<br />WALL HUNG
<br />O.D.
<br />OUTSIDE DIAMETER
<br />W. 1.
<br />WROUGHT IRON
<br />O.F.I.
<br />OWNER FURNISH & INSTALL
<br />W.M.
<br />WIRE MESH
<br />O.F.C.I.
<br />OWNER FURNISH, CONTRACTOR INSTALL
<br />W. P.
<br />WATERPROOFING
<br />O.F.V.I.
<br />OWNER FURNISH, VENDOR INSTALL
<br />W.S.
<br />WEATHER STRIP
<br />O.H.
<br />OVERHEAD
<br />W.W.F.
<br />WELDED WIRE FABRIC
<br />OPG.
<br />OPENING
<br />®� /
<br />SITE NORTH
<br />LOCATION
<br />DRAWING INDEXJ.
<br />GENERAL
<br />G001 COVER, NOTES, CODE SUMMARY, DRAWING INDEX & LOCATION MAP
<br />G101 LIFE SAFETY PLAN
<br />ARCHITECTURAL
<br />A001 GENERAL DEMOLITION NOTES, PARTITION TYPES, DETAILS, AND FINISH SCHEDULE
<br />A151 DEMOLITION PLANS, NOTES, AND DETAILS
<br />A201 PLANS, DOOR AND WINDOW ELEVATIONS, DOOR SCHEDULE, AND NOTES
<br />A201E PLANS, EQUIPMENT SCHEDULE, AND NOTES
<br />A600 FIRE RATED CONSTRUCTION DETAILS
<br />A800 INTERIOR ELEVATIONS AND CASEWORK DETAILS
<br />MECHANICAL
<br />M001 MECHANICAL NOTES, SCHEDULES, AND SHEET INDEX
<br />M002 MECHANICAL SPECIFICATIONS
<br />M003 MECHANICAL SPECIFICATIONS
<br />M300 MECHANICAL PARTIAL FLOOR PLAN - DEMOLITION AND NEW CONSTRUCTION
<br />M501 MECHANICAL DETAILS
<br />PLUMBING
<br />P001 PLUMBING NOTES AND SHEET INDEX
<br />P200 PLUMBING PARTIAL FLOOR PLAN - DEMOLITION AND NEW CONSTRUCTION
<br />ELECTRICAL
<br />E001 ELECTRICAL LEGEND, NOTES, SHEET INDEX
<br />E002 ELECTRICAL SPECIFICATIONS REVIEW DATE
<br />E003 ELECTRICAL SPECIFICATIONS CITY OF ZEPHYRHI LS
<br />E201 ELECTRICAL PARTIAL FLOOR PLAN - DEMOLITION PLAN EXAMINE
<br />E301 ELECTRICAL PARTIAL FLOOR PLAN - NEW CONSTRUCTION
<br />E402 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES
<br />E501 ELECTRICAL DETAILS
<br />'ILL WORK SHALL COMPLY WITH
<br />'REVAILING CODES
<br />=LORIDA BUILDING CODE,
<br />EQUIPMENT VENDOR DOCUMENTS - GQf6WthCaEeTRIC CODE, AND
<br />THE ATTACHED GE HEALTHCARE DOCUMENT P4CKAGE IS YRHILLS ORDINAN(
<br />PROVIDED FOR CONTRACTOR REFERENCE. CONTACT
<br />MANUFACTURER FOR ALL EQUIPMENT DESIGN, FUNCTION, AND
<br />OPERATION QUESTIONS OR CONCERNS
<br />C1 COVER SHEET, SITE READINESS, NOTES, AND DRAWING INDEX
<br />Al EQUIPMENT LAYOUT REVIEW DATE
<br />sl STRUCTURAL LAYOUT CITY OF ZEPHYRHILLS
<br />S2 STRUCTURAL DETAILS PLAN EXAMINER
<br />E1 ELECTRICAL LAYOUT _
<br />E2 ELECTRICAL SPECIFICATIONS
<br />E3 ELECTRICAL DETAILS
<br />D1 EQUIPMENT DETAILS
<br />D2 EQUIPMENT DETAILS
<br />SCOPE OF WORK
<br />SCOPE OF WORK CONSISTS OF THE FOLLOWING:
<br />INTERIOR RENOVATION TO AN EXISTING BUILDING - WORK WILL
<br />INCLUDE REMOVAL OF EXISTING PARTITIONS, DOORS,
<br />EQUIPMENT, AND CEILING. NEW WORK CONSISTS OF NEW
<br />INTERIOR PARTITIONS, INSTALLATION OF NEW DOORS/FRAMES/
<br />SIDELITES, NEW CASEWORK AND ASSOCIATED PLUMBING
<br />FIXTURES, NEW CEILING AND ASSOCIATED ELECTRICAL AND
<br />MECHANICAL FIXTURES, AS WELL AS NEW INTERIOR FINISHES.
<br />NO NEW AREA IS BEING ADDED AS A PART OF THIS PROJECT.
<br />SaltCo, LLC
<br />AA 26001479
<br />General Notes:
<br />DO NOT SCALE DRAWINGS.
<br />VENDOR PROVIDED EQUIPMENT SHOWN FOR REFERENCE ONLY —
<br />REFER TO OWNER PROVIDED VENDOR DOCUMENTS FOR
<br />ADDITIONAL INFORMATION. CONTACT EQUIPMENT MANUFACTURER
<br />FOR EQUIPMENT RELATED QUESTIONS OR CONCERNS.
<br />CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE
<br />DRAWINGS AND SPECIFICATIONS AND NOTIFY THE ARCHITECT OF ANY
<br />ERRORS OR INCONSISTENCIES PRIOR TO BEGINNING WORK.
<br />CONTRACTOR SHALL VERIFY AND COORDINATE CLEAR DIMENSIONS
<br />REQUIRED FOR OWNER/VENDOR FURNISHED EQUIPMENT AND
<br />NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS AND
<br />PROCEED ONLY UPON RESOLUTION.
<br />COLOR, STYLE, PATTERN AND MANUFACTURER OF INTERIOR
<br />FINISHES MAY VARY. SELECTIONS BY OWNER. VERIFY PRIOR TO
<br />INSTALLATION.
<br />MAINTAIN COMPLIANCE WITH OWNER —FURNISHED RADIATION SHIELDING
<br />REQUIREMENTS — IN ANY RENOVATED, AND NEW CONSTRUCTION.
<br />EXISTING EQUIPMENT REFERENCED AND/OR NOT SHOWN, IS REMOVED
<br />BY OTHERS — UNDER SEPARATE AGREEMENT WITH OWNER.
<br />REPAIR ANY PENETRATIONS/HOLES ON EXISTING FIRE OR SMOKE RATED,
<br />AND LEAD —LINED WALLS WITHIN THE SCOPE OF THE WORK, IN ORDER
<br />TO MAINTAIN THE INTEGRITY OF ALL REQUIRED FIRE / SMOKE RATINGS
<br />— INSTALL FIRESAFING AS REQUIRED FOR COMPLIANCE (SEE SHEET
<br />A600 FOR FURTHER CLARIFICATION), AND LEAD LINING
<br />REQUIREMENTS.
<br />MAKE NECESSARY ADJUSTMENTS TO GWB PARTITIONS, IN ORDER TO
<br />ACCOMMODATE NEW RECESSED CABLE DUCTS/CONDUITS. PATCH AND
<br />MATCH REMAINING ADJACENT SURFACES — RADIATION SHIELDING SHALL
<br />COMPLY WITH SHIELDING PLAN. SEE DETAIL C2/A201 E FOR FURTHER
<br />INFORMATION.
<br />WALLS SHOWN IN ALIGNMENT ARE TO ALIGN WITH FINISHED SURFACE.
<br />PROVIDE AND INSTALL FLORIDA BUILDING CODE APPROVED
<br />SUBTERRAINIAN TERMITICIDE AT ALL COMPACTED SOIL TO BE COVERED
<br />WITH CONCRETE FLOOR SLAB. RETREAT ALL AREAS DISTURBED BY PIPE
<br />AND CONDUIT INSTALLATION, OR OTHER CONSTRUCTION WORK, PRIOR TO
<br />NEW SLAB INSTALLATION. CONTRACTOR TO VERIFY TERMITICIDE
<br />INSTALLATION IS IN COMPLIANCE WITH FLORIDA BUILDING CODE SECTION
<br />1816, AND THAT WORK IS PERFORMED BY CERTIFIED PERSONNEL ONLY.
<br />ANCER_
<br />(S P E C I ,A L I S T
<br />Research Institute
<br />Key Plan
<br />MARK ISSUE DATE DESCRIPTION
<br />Issue Log
<br />JOHN P. SALT AR 92309
<br />FLORIDA CANCER SPECIALISTS
<br />EQUIPMENT REPLACEMENT
<br />38010 MEDICAL CENTER AVE.
<br />ZEPHYRHILLS, FL 33540
<br />Drawing Title
<br />COVER, NOTES, CODE SUMMARY,
<br />DRAWING INDEX, AND
<br />LOCATION MAP
<br />Commission No.
<br />71604
<br />Date Issued
<br />07/01/16
<br />Scale
<br />AS NOTED
<br />Sheet Number
<br />GOT
<br />Drawn By C2
<br />Approved By JPS
<br />—
<br />Filename 71506 0001
<br />Sa1tCo, LLC 2012
<br />
|