My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36036 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
36036 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:35:34 AM
Creation date
2/19/2025 11:29:25 AM
Metadata
Fields
Template:
Building Plans
Street #
36036
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20427
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ff� � Woo Mmo' 00, pmr, I MO- - <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1.1 <br />FIRST FLOOR PLAN <br />EH_l LI, COMPLY WITH PREVAILING <br />ALLWa*'K <br />CODES FI,C)RIDA SUILIL.ING COODE, <br />1.2 <br />SECOND FLOOR PLAN <br />NATIONAL ELECTRIC, t, ODE, <br />AND THE Ct-rf. Or ZEPHYRHILLS <br />REVIEW DA7'1= � � �J, <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />ORDINANCES CITY <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAIL <br />4.1 <br />FIRST FLOOR ELECTRICAL PLAN <br />4.2 <br />SECOND FLOOR ELECTRICAL PLAN <br />5.1 <br />ROOF PLAN <br />6.1 <br />FOUNDATION PLAN <br />7.1 <br />FLOOR FRAMING PLAN <br />ABBREVIATIONS <br />7.2 <br />ROOF FRAMING PLAN <br />- <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />RA or R/A or R.A. Return Air <br />8 <br />LINTEL DETAILS <br />SN <br />STRUCTURAL NOTES <br />ABV orAbv. Above <br />FLR or Fir. Floor <br />RAG or Rag. Return Air Grill <br />AC or A/C Air -Conditioner <br />FLR SYS or Fir Sys Floor System <br />RAD or Rad. <br />Radius <br />ADJ or ADJ. Adjustable <br />FOM or F.O.M. Face Of Masonry <br />REC or Rec. <br />Recessed <br />SN 1 <br />DETAILS <br />S3M <br />DETAILS <br />AFF or A.F.F. Above Finished Floor <br />FP or F.P. Fireplace <br />RECEPT Receptacle <br />AHU or A.H.U. Air Handler Unit <br />FR DR French Door <br />REF or Ref. <br />Refrigerator <br />ALTorALT. Alternate <br />FRT Front <br />REINF <br />Reinforcing <br />S4 <br />DETAILS <br />BC Base Cabinet <br />BF Bifold Door <br />FT or Ft. Foot/ Feet <br />FTG or Ftg. Footing <br />REQD or Req'd. <br />RM or Rm. <br />Required <br />Room <br />S5 <br />DETAILS <br />S6M <br />DETAILS <br />BK SH or Bk Sh BookShelf <br />GALV or Galy. Galvanized <br />RND or Rnd. RoundMEN <br />E E <br />BLK or BLK. Block <br />GC or G.C. General Contractor <br />RO or R.O. <br />Rough Opening <br />ST <br />BLW or BLW. Below <br />GFI or G.F.I. Ground Fault Interrupter <br />RS or R/S or R&S <br />Rod and Shelf <br />DETAILS <br />SS <br />RETROFIT DETAILS <br />BM or Bm. Beam <br />GT or G.T. Girder Truss <br />SD or SD. Smoke Detector <br />BOT or Bot. Bottom <br />GYP BD or Gyp. Bd. Gypsum Board <br />SO FT or SF or S.F. <br />Square Foot (feet) <br />BP or B.P. Bypass (door) <br />HB Hose Bibb <br />SGD <br />Sliding Glass Door <br />D1 <br />SECTIONS &DETAILS <br />D2 <br />SECTIONS & DETAILS <br />BRG or BRG. Bearing <br />HDR or Hdr. Header <br />SH or Sh. Shelves <br />C Carpet <br />HGTorHgt. Height <br />SHWRorShwr. <br />Shower <br />WP <br />WATERPROOFING DETAILS <br />CAB Cabinet <br />HH or H.H. Hand Held (plumbing faucet) <br />SHT <br />Sheet <br />CIR or Cir. Circle <br />HORIZ Horizontal <br />SL or S.L. <br />Side Lights <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />CJ or C/J Control Joint <br />HS Hard Surface (flooring) <br />SPF or S.P.F. <br />Spruce Pine Fir <br />CLG or Clg. Ceiling <br />ILO In Lieu Of <br />SPECS or SPECS. <br />Specifications <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />CMU Concrete Masonry Unit <br />INSUL or Insul. Insulation <br />SQ or Sq. <br />Square <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />COFF or Coff. Coffered or Tray Ceiling <br />INT or Int. Interior <br />STO <br />Storage <br />PA1.3 <br />PRODUCTAPPROVAL NUMBERS <br />COL or Col. Column <br />KIWALLorK/Wall Kneewall <br />SW or S.W. Shear Wall <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />KS or K.S. Knee Space <br />LAUN or Laun. Laundry <br />SYP or S.Y.P. <br />TB <br />Southern Yellow Pine <br />Towel Bar <br />CONN or CONN. Connection <br />LAV or Lay. Lavatory <br />TEMP or Temp. <br />Tempered <br />CT or C.T. Ceramic Tile <br />D or D. Dryer <br />LF or L.F. Linear Ft. <br />LL Lintel Length <br />THIKN or Thik'n. <br />TOB or T.O.B. <br />Thicken <br />Top of Block <br />DB Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. Double <br />DCF Decorative Cementitious Finish <br />MGT Management (room) <br />MAS or Mas. Masonry <br />TOP or T.O.P. <br />TP <br />Top of Plate <br />Toilet Paper Holder <br />DEC or Dec. Decorative <br />MAX or Max Maximum <br />TR <br />Towel Ring <br />DED or Ded. Dedicated (outlet) <br />MC Medicine Cabinet <br />TRANS WDW or Trans. <br />Transom Window <br />DIA or Dia. Diameter <br />MFR or Mfr. Manufacturer <br />TYP or Typ. Typical <br />DISPorDisp. Disposal <br />MW or MICRO or Micro. Microwave <br />UCoru.c. <br />Under Counter <br />DIST or Dist. Distance <br />MIN or Min Minimum <br />UCL <br />Under Cabinet Lighting <br />DMF Decorative Masonry Finish <br />MIR or Mir. Mirror <br />UNO or U.N.O. Unless Noted Otherwise <br />DS or D.S. Drawer Stack <br />ML or M.L. Microlam <br />V or v. <br />Valve (shower or tub/shower) <br />DTL Detail <br />MONO or Mono Monolithic <br />VB <br />Vanity Base <br />DV or D.V. Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />o <br />DVP or D.V. P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL or V.L. <br />Versalam <br />in <br />DW or D.W. Dishwasher <br />OPNG or Opn'g. Opening <br />VTR Vent through Roof <br />�2 <br />EA or Ea. Each <br />OPT or Opt. Optional <br />W or w <br />Washer <br />o <br />EW or E.W. Each Way <br />PC Pull Chain <br />W/ or w/ <br />With <br />ELEC or Elec. Electrical <br />PED or Ped. Pedestal <br />WC or W/C or W.C. Water Closet (toilet) <br />N <br />ELEV or Elev. Elevation <br />PH Phone <br />WA or W.A. Wedge <br />Anchor <br />,N <br />EQ Equal <br />PKT or Pkt. Pocket (Door) <br />WD or Wd <br />Wood <br />EXT or Ext. Exterior <br />PL or P.L. Parallam <br />WDW HDR or WDW. HDR. Window Header <br />coEXP <br />or Exp. Expansion <br />PLF Pounds per linear foot <br />WH or W.H. <br />Water Heater <br />FBC Florida Building Code <br />PLT HT or Pit. Ht. Plate Height <br />WIC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />FXD GL Fixed Glass <br />PSF Pounds per square foot <br />WP <br />Water Proof(ing) <br />0° <br />FG Fiberglass (Shower Pan) <br />PT or P.T. Pressure Treated <br />WS Water Softener <br />FIN Finished <br />PW or P.W. Pre -wire <br />WWF <br />Welded Wire Fabric (Mesh) <br />o <br />FIN FLR or FF or Fin. Flr. Finished Floor <br />PWDR or Pwd. Powder Room <br />v <br />N <br />REVISIONS <br />CV <br />O <br />06-09-17 1.0 <br />NEW BASE PLAN <br />12-28-17 2.0 <br />2017 FBC CODE UPDATE <br />O <br />01-04-18 3,0 <br />ADDED HVAC IN LAUNDRY <br />N <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />o <br />02-21-18 4.0 <br />ADDED GRADE BEAM 150 MPH ENG. <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />0O <br />04-13-18 4.1 <br />REV. DOOR TO WC IN M. BATH <br />FOR 2 STORY HOMES <br />E <br />9 <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />g <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />LZ <br />OF CODE SECTIONS. SEE <br />o <br />FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />CC, <br />Notice to Builder & All Subcontractors <br />C <br />y <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />i <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />N <br />undetected and not reported to the Designer / Engineer prior to <br />o <br />construction. All construction MUST be in accordance to the <br />04 <br />information found in these documents. Any questions regarding <br />`D <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />w <br />Payments will be made in accordance to the terms of the <br />agreement. <br />C4 <br />M <br />Z 0 <br />—C) <br />z� <br />z <br />I� Z <br />Cn CO <br />w <br />r6 p <br />�V — <br />OLU <br />�V) <br />U <br />o0 <br />m N <br />w E <br />pp <br />N M <br />Cn M <br />M_ <br />S <br />aimU <br />-M <br />0.9 0 <br />L U_ 00 <br />00 <br />o <br />¢ m <br />U) ao <br />LL7 0 v <br />01 Q d <br />A IL <br />O V N <br />N <br />Z <br />MNIb W Z Z <br />H .2 i <br />LU 4f N <br />LU <br />Zn <br />T 24 o <br />..—w <br />Z o co 9, <br />IJ,1UM <br />O v U O <br />WWW.FDSEN 11 Li <br />�?,OWN <br />�s <br />rP <br />. <br />h 0q <br />F. <br />X <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENIMAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0Z <br />�Q <br />¢ce <br />wit <br />UEOO <br />5 U L) <br />Z uJ <br />a � J <br />uj m <br />ILIJ <br />8 <br />6 V 0 <br />LU <br />Z <br />}0 <br />f <br />z <br />Z <br />V <br />f <br />W <br />F <br />o <br />0 <br />o <br />; <br />U <br />J L1J <br />H <br />U0 <br />N <br />O Z <br />SRO <br />"..-< <br />Lu <br />U a <br />*k <br />N <br />�7 <br />Z¢Z¢ <br />W <br />Q <br />Lr) <br />o � <br />Z <br />fV <br />0 <br />� 36 � <br />lJJ <br />J <br />Lr)tj.j <br />rl <br />LJJ <br />< <br />Z <br />0 a z o <br />� F <br />g~WWo <br />go <br />Z <br />C Z <br />ao0 <br />0 <br />06 <br />Z <br />g <br />LU <br />J <br />t2 <br />U <br />o <br />SCALE : AS NOTED <br />DATE : 6/20/2018 <br />TECH: MJAM ES <br />VERSION NO. 4ol <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.