Laserfiche WebLink
1 <br />I <br />r <br />i <br />® i <br />S <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1.1 <br />FIRST FLOOR PLAN <br />1.2 <br />SECOND FLOOR PLAN <br />2.1 <br />EXTERIOR ELEVATIONS <br />2.2 <br />EXTERIOR ELEVATIONS <br />3 <br />ELECTRICAL PLAN <br />_ _ <br />4 <br />ROOF PLAN <br />5 <br />FOUNDATION PLAN <br />6.1 <br />FIRST FRAMING PLAN <br />6.2 <br />SECOND ROOF FRAMING PLAN <br />7 <br />LINTEL PLAN AND DETAILS <br />SN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />SN1 <br />DETAILS <br />1 <br />S3 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />FIX or FXD Fixed <br />PWDR or Pwd. Powder Room <br />S4 <br />DETAILS <br />ABV or Abv. Above <br />FLR or Fir. Floor <br />RA or RIA or R.A. Return Air <br />AC or A/C <br />ADJ orADJ. <br />Air -Conditioner <br />Adjustable <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />RAD or Red. Radius <br />RAG or Rag. Return Air Grill <br />S5 <br />DETAILS <br />S6 <br />DETAILS <br />AFF or A.F.F. Above Finished Floor <br />FP or F.P. Fireplace <br />REC or Rec. Recessed <br />AHU orA.H.U. <br />Air Handler Unit <br />FR DR French Door <br />RECEPT Receptacle <br />ALT or ALT. <br />Alternate <br />FRT Front <br />REF or Ref. Refrigerator <br />ST <br />STAIR DETAILS <br />BC <br />BF <br />Base Cabinet <br />Bifold Door <br />FT or Ft. Foot/ Feet <br />FTG or Ftg, Footing <br />REINF Reinforcing <br />REQD or Req'd. Required <br />SS <br />RETROFIT DETAILS <br />---- <br />-------------- —-- <br />BK SH or Bk Sh <br />Bookshelf <br />FXD GL Fixed Glass <br />RM or Rm. Room <br />D1 <br />SECTIONS & DETAILS <br />BLK or BLK. <br />BLW or BLW. <br />Block <br />Below <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />RND or Rnd. Round <br />RO or R.O. Rough Opening <br />D2 <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />BM or sm. Beam <br />GFI or G.F.I. Ground Fault Interrupter <br />RS, RIS, R/SH or R&S Rod and Shelf <br />BOTorBot. <br />BP or B.P. <br />Bottom <br />Bypass (door) <br />GTorG.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />SD or SD. Smoke Detector <br />SGD Sliding Glass Door <br />PA1.0 <br />PRODUCTAPPROVALNUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />BRG or BRG. Bearing <br />HB Hose Bibb <br />SH or Sh. Shelves <br />C <br />CAB <br />Carpet <br />Cabinet <br />HDR or Hdr. Header <br />HGT or Hgt Height <br />SHT Sheet <br />SHWR or Shwr. Shower <br />pA1,2 <br />PRODUCT APPROVAL NUMBERS <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />CIR or Cir. Circle <br />HH or H.H. Hand Held (plumbing faucet) <br />SL or S.L. Side Lights <br />CJ orC/J <br />CLG or Clg. <br />Control Joint <br />Ceiling <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />SPECS or SPECS. Specifications <br />SPF or S.P.F. Spruce Pine Fir <br />SH1.0 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CMU <br />Concrete Masonry Unit <br />ILO In Lieu Of <br />SQ FT or SF or S.F. Square Foot (feet) <br />SH1.1 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COFForCoff. <br />COL or Col. <br />Coffered or Tray Ceiling <br />Column <br />INSULorinsul. Insulation <br />INT or Int. Interior <br />SQorSq. Square <br />STO Storage <br />SH1.2 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMM orComm. <br />Community <br />KIWALLorK/Wali Kneewall <br />SW or S.W. Shear Wall <br />SH1.3 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />COMP or Comp. <br />Compressor <br />KS or K.S. Knee Space <br />SYP or S.Y.P. Southern Yellow Pine <br />SH1.4 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />CONN or CONN. Connection <br />LAUN or Laun. Laundry <br />TB Towel Bar <br />CONT or Cont. <br />CT or C.T. <br />Continuous <br />Ceramic Tile <br />LAV or Lay. Lavatory <br />LForL.F. Linear Ft. <br />TEMP or Temp. Tempered <br />THIKNorTWO. Thicken <br />SH1.5 <br />HURRICANE SHUTTER PRODUCT APPROVAL <br />D or D. <br />Dryer <br />LL Lintel Length <br />TOB or T.Q.B. Top of Block <br />v — <br />DB <br />Door Bell <br />LT Laundry Tub <br />TOM or T.O.M. Top of Masonry <br />--------------------------- <br />— — — — — — — — — — — — — — — — — — <br />— <br />DBL or Dbl. Double <br />MAS or Mas. Masonry <br />TOP or T.O.P. Top of Plate <br />DCF <br />Decorative Cementitious Finish <br />MAX or Max Maximum <br />TP Toilet Paper Holder <br />J <br />DEC or Dec. <br />Decorative <br />MC Medicine Cabinet <br />TR Towel Ring <br />DED or Ded. Dedicated (outlet) <br />MFR or Mfr. Manufacturer <br />TRANS WDW or Trans. Transom Window <br />DIA or Dia. <br />Diameter <br />MGT Management (room) <br />TYP or Typ. Typical <br />DISP or Disp. <br />Disposal <br />MIN or Min Minimum <br />UC or u.c. Under Counter <br />DIST or Dist. Distance <br />MIR or Mir. Mirror <br />UCL Under Cabinet Lighting <br />DMF <br />Decorative Masonry Finish <br />ML or M.L. Microlam <br />UNO or U.N.O. Unless Noted Otherwise <br />DS or D.S. <br />DTL <br />DV or D.V. <br />Drawer Stack <br />Detail <br />Dryer Vent <br />MONO or Mono Monolithic <br />MW or MICRO or Micro, Microwave <br />NTS or N.T.S. Not to Scale <br />V or v. Valve (shower or tub/shower) <br />VB Vanity Base <br />VERT or Vert. Vertical <br />, 1M <br />��� <br />FE7:1 M 7E: 10 M M <br />. ❑ <br />MEAN ROOF 1 FT. HIGH TYPICAL <br />E 5 <br />FOR SINGLE STORY HOMES <br />DVPorD.V.P. <br />DWorD.W. <br />EA or Ea. <br />DiverferValve (plumbing) <br />(p g) <br />Dishwasher <br />Each <br />OE or O.E. Owners Ent ry <br />OPNGorOpn'g. Opening <br />OPT or Opt. Optional <br />VLorV.l. Versalam <br />VTR orVTE Vent through Roof/Exterior <br />W or w Washer <br />U <br />>J <br />F-1 El E�] [::IF—] El E] E] <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />ELECorElec. <br />ELEV or Elev. <br />EQ <br />Electrical <br />Elevation <br />Equal <br />PC Pull Chain <br />PED or Pad. Pedestal <br />PH Phone <br />wlorwl With <br />WA or W.A. Wedge Anchor <br />WC or W/C or W.C. Water Closet (toilet) <br />THIS DRAWING AND DESIGN IS VALID <br />EWorE.W. Each Way <br />PKTorPkt. Pocket (Door) <br />WDorWd Wood <br />DEI 1 ElE] 1 a <br />EXP or Exp. <br />EXTorExt. <br />FBC <br />FDN or Fdn. <br />Expansion <br />Exterior <br />Florida Building Code <br />Foundation <br />PL or P.L. Parailam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />PLT HT or Pit. Ht. Plate Height <br />WDWHDR orWDW. HDR. Window Header <br />WHorW.H. Water Heater <br />Walk-in Closet <br />WIC or W.I.C.S <br />WM or W.M. Wall Mounted (plumbing fixture) <br />a <br />FOR 12 MONTHS AFTER THE DATE IT <br />SIGNED AND SEALED OR WHILEC. <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />FG Fiberglass (Shower Pan) <br />PSF Pounds per square foot <br />WP WaterProof(ing) <br />FIN <br />FIN FLR or FF or Fin. Fir. <br />Finished <br />Finished Floor <br />PT or P.T. Pressure Treated <br />PWorP.W. Pre -wire <br />WS Water Softener <br />WWF Welded WireFabric (Mesh) <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />04/25/12 <br />1.0 <br />NEW BASE PLAN <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />06/25/ 1 2 <br />2.0 <br />GRADE BEAM FOUNDATION <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />08/11 /15 <br />3.0 <br />2015 NEW CODE UPDATE <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />�+ p <br />FBC 2017 CODE UPDATES & MODEL <br />03/06/18 4.0 <br />UPDATES <br />advanced notification and approval by the Designer/Engineer. <br />Payments <br />REVISED SGD, LANAI & WINDOWS <br />06/01/18 4.1 <br />AT REAR <br />06/07/ 18 4.2 REVISED DINING WINDOW TO 35-S H <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />12/ 19/20 <br />5.0 <br />FBC 2020 CODE <br />UPDATE <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />Ism <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />1763 <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />c <br />W <br />O <br />�ow�" <br />C ) eat <br />m <br />-W _Cb cc <br />3 ;6 <br />CV <br />N <br />O <br />CD <br />ins., <br />a! ' <br />� v <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only <br />for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W aE <br />0 N W N N_ onD <br />LQa O N O <br />°� <br />N �Q <br />0M) <br />Y. J <br />ui M V LL <br />� Lt. <br />CQ LPL, LL a <br />Z O3 ° <br />L r p o <br />W _ <br />W ��030' m w <br />a0 (j 1 <br />u1 Z <br />IL IL <br />ZN OU < <br />W El 17-1 <br />V M � <br />z n M <br />o � <br />z <br />z o <br />— <br />M <br />V I <br />V) z <br />C1 j C9 s <br />U- <br />fD w <br />U n <br />Cr <br />,,, <br />V) <br />C/I <br />co <br />w � <br />ryy <br />L <br />I <br />i?J <br />m <br />J?co <br />® 0 <br />¢ N m <br />o <br />W <br />M <br />� � <br />O <br />Z <br />LL <br />f? E <br />wo <br />wo <br />>�Y <br />n® <br />wx <br />!� @ <br />a <br />a` <br />00 <br />oZ <br />N � <br />4% L <br />az <br />wo <br />¢o <br />Wz <br />ra <br />CY <br />m0 <br />o <br />z`'` <br />Z <br />aw <br />a <br />H <br />w <br />1 <br />Ez <br />wW <br />� <br />Q <br />z <br />CO <br />�C <br />0 <br />`O <br />o <br />ui <br />cc <br />C) <br />N <br />� <br />M �, <br />r <br />` <br />U)'^ U <br />o <br />m <br />N <br />Z <br />LO <br />� <br />N <br />0 <br />C3) <br />(0 <br />O <br />lid <br />r <br />� <br />r <br />ui <br />C\V <br />Sri <br />d <br />z <br />ca <br />Z <br />E 7-- <br />m <br />a <br />Eo <br />U Q p <br />JOB <br />NO: 22-06455 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />