Laserfiche WebLink
List Of Abbreviations <br />A A/C <br />AIR CONDITION <br />E EL <br />ELEVATION <br />L <br />LAV <br />LAVATORY S <br />SC <br />SOLID CORE <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />LBL <br />LABEL <br />SCHED <br />SCHEDULE <br />ACT <br />ACOUSTICAL CEILING TILE ELEV <br />ELEVATOR <br />LBS <br />POUNDS <br />SCP <br />SCUPPER <br />AD <br />ADJUSTABLE, ADJACENT EMER <br />EMERGENCY <br />LF <br />LINEAR FEET <br />SD <br />SOAP DISPENSER <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />LT WT <br />LIGHT WEIGHT <br />SEAL <br />SEALANT <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />SECT <br />SECTION <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />M <br />MAS <br />MASONRY <br />SF <br />SQUARE FEET <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />MAX <br />MAXIMUM <br />SHT <br />SHEET <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />MECH <br />MECHANICAL <br />SIM <br />SIMILAR <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />MFR <br />MANUFACTURER <br />SPEC <br />SPECIFICATION <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />MH <br />MANHOLE <br />SS <br />STAINLESS STEEL, <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />MIN <br />MINIMUM <br />SERVICE SINK <br />AUTO <br />AUTOMATIC <br />MIN <br />MINIMUM, MINUTE <br />STD <br />STANDARD <br />F FACP <br />FIRE ALARM <br />MISC <br />MISCELLANEOUS <br />STL <br />STEEL <br />B B 0 <br />BOTTOM OF <br />CONTROL PANEL <br />MLDG <br />MOLDING <br />STOR <br />STORAGE <br />BD <br />BOARD <br />FD <br />FLOOR DRAIN <br />MO <br />MASONRY OPENING <br />STRUC <br />STRUCTURAL <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />MR <br />MOISTURE RESISTANT <br />SUSP <br />SUSPENDED <br />BM <br />BEAM <br />FIN <br />FINISHED <br />MTD <br />MOUNTED <br />SY <br />SQUARE YARD <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />MTL <br />METAL <br />BTM <br />BOTTOM <br />FR <br />FIRE RESISTANT <br />MUL <br />MULLION T <br />T <br />TREAD <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />T&G <br />TONGUE & GROOVE <br />WOOD TREATMENT <br />N <br />NIC <br />NOT IN CONTRACT <br />TBL <br />TABLE <br />C CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />NOM <br />NOMINAL <br />TELE <br />TELEPHONE <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />NTS <br />NOT TO SCALE <br />TEMP <br />TEMPERED <br />CI <br />CAST IRON <br />FURR <br />FURRING <br />THK <br />THICK <br />CJ <br />CONTROL JOINT <br />FLIT <br />FUTURE <br />0 <br />OC <br />ON CENTER <br />TILT <br />TOILET <br />CL <br />CENTER LINE <br />OD <br />OUTSIDE DIAMETER <br />TO <br />TOP OF <br />CLG <br />CEILING <br />G GA <br />GAUGE <br />OPP <br />OPPOSITE <br />TPD <br />TOILET PAPER <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />OVFL <br />OVERFLOW <br />DISPENSER <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />TS <br />TUBE STEEL <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />P <br />PL <br />PLATE <br />TV <br />TELEVISION <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />PLAM <br />PLASTIC LAMINATE <br />TYP <br />TYPICAL <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />PLAS <br />PLASTER <br />COL <br />COLUMN <br />PLBG <br />PLUMBING U <br />LION <br />UNLESS OTHER- <br />CONC <br />CONCRETE <br />H HB <br />HOSE BIBB <br />PLWD <br />PLYWOOD <br />WISE NOTED <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />PNL <br />PANEL <br />UTIL <br />UTILITY <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />PR <br />PAIR <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />PREFAB PREFABRICATED V <br />VB <br />VINYL BASE <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />PT <br />POINT <br />VCT <br />VINYL COMPOSITE TILE <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />PT <br />PRESSURE TREATED <br />VERT <br />VERTICAL <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />PTD <br />PAPER TOWEL DISPENSER <br />VEST <br />VESTIBULE <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />PVC <br />POLY VINYL CLORIDE <br />VIF <br />VERIFY IN FIELD <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />VTR <br />VENT THRU ROOF <br />& AIR CONDITIONING <br />Q <br />QT <br />QUARRY TILE <br />VWC <br />VINYL WALL COVERING <br />D DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />R <br />R <br />RADIUS, RISER, W <br />W <br />WIDTH <br />DET <br />DETAIL <br />I ID <br />INSIDE DIAMETER <br />THERMAL RESISTANCE <br />W/ <br />WITH <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />RD <br />ROOF DRAIN <br />W/0 <br />WITHOUT <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />RECP <br />RECEPTACLE <br />WC <br />WATER CLOSET <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />REF <br />REFERENCE <br />WD <br />WOOD <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />REFR <br />REFRIGERATOR <br />WH <br />WATER HEATER <br />DN <br />DOWN <br />INV <br />INVERT <br />REG <br />REGLET <br />WP <br />WATERPROOF <br />DS <br />DOWNSPOUT <br />REINF <br />REINFORCEMENT <br />WT <br />WEIGHT <br />DWG <br />DRAWING <br />J JAN <br />JANITOR <br />REO <br />REQUIRED <br />WWF <br />WELDED WIRE FABRIC <br />E <br />JB <br />JUNCTION BOX <br />REV <br />REVISION <br />WWM <br />WELDED WIRE METAL <br />EA <br />EACH <br />JT <br />JOINT <br />RM <br />ROOM <br />EB <br />EXPANSION BOLT <br />RND <br />ROUND Y <br />YD <br />YARD <br />EIFS <br />EXTERIOR INSULATING <br />L L <br />LENGTH <br />RO <br />ROUGH OPENING <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />RTU <br />ROOF TOP UNIT <br />EJ <br />EXPANSION JOINT <br />Legend <br />t�X <br />GRID DESIGNATION <br />BUILDING <br />SECTION <br />A301-2 A301-2 <br />102 <br />ROOM NUMBER <br />SHEET <br />NUMBER <br />-� - SECTION NUMBER <br />102A <br />DOOR NUMBER <br />WALL SECTION <br />A302-3 <br />NUMBER <br />40 <br />SHEET <br />SECTION NUMBER <br />WINDOW TYPE <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity Map <br />NTS <br />m <br />CD <br />CD <br />Riac k pia rd LA <br />lip <br />KOSSIK RD <br />Kass k Rd3a OijsAln Ad <br />. Tall Dr <br />n _I <br />S' PROJECT <br />Kyte4.rf <br />Dr 1�1 SITE <br />U Rd i 0111 <br />. s <br />Ptr+t fide t �r$s lei <br />„ Aj <br />n tv Jt a C? <br />T <br />prig ty POM Ltd . <br />Prk <br />(7-, r n A w <br />Ave TreI16 Ave RuAnn <br />Ave F , <br />Te��1p Aug �1 �-t Ave� 'A�eA <br />Rut d4re r <br />For, King Rd Amca.,._ " Ave `, ge. P <br />Of � � DAutjhtei v Pd <br />Ave <br />�I <br />� knwz Ave <br />C'I�n 'a r <br />7,1 ? untyLnVeILisAve <br />of <br />141d°Kt fi4 '8 <br />5+�var� <br />Orient Avg <br />a1:rc�# Ilvrc a °� yr Road. 4 4_ j <br />COUNT ; GOAD 54 <br />� „ ! s +4dv en .Ave � <br />4 irYit+t Ram Z <br />e t o Leo e1 ki Ave <br />�a .� pay r„�, � «� <br />7810, 7814, 7818 & 7822 GALL BLVD, ZEPHYRHILLS, FLORIDA <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS <br />5335 8TH STREET <br />ZEPHYRHILLS, FL 33542 <br />3 SIGNED & SEALED SETS FOR PERMIT <br />(813) 780-0020 - PHONE <br />(813) 780-0021 - FAX <br />ADOPTED CODES: <br />2 STOREFRONT TYPE A501-6 SECTION DETAIL <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (W/ 2009 AMENDMENTS) <br />- SHEET NUMBER DETAIL NUMBER (CHAPTER 36 - NFPA 1 & NFPA 101 W/ STATE FIRE MARSHAL AMENDMENTS) <br />-- WALL TYPE PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (W/ 2009 AMENDMENTS) <br />_ ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />`5 KEY NOTE A888-88 DETAIL REFERENCE (CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) <br />FUEL/GAS: FLORIDA BUILDING CODE, FUEL/GAS - 2007 (W/ 2009 AMENDMENTS) <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />SHEET NUMBER - DETAIL NUMBER (CHAPTER 11 - FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />%6-\ REVISION NUMBER ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />� TO SOMETHING �. <br />XX' XX" ELEVATIONS TAGS f� L ( EXTERIOR ELEVATION <br />A201-2 o > ' MARKERS <br />N ,F BUILDING AND CONSTRUCTION DATA <br />1 ap% <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE <br />+' SHEET NUMBER -ELEVATION NUMBER CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />SPOT ELEVATION TAG <br />• 1 MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES <br />,) ACTUAL HEIGHT 38'-6" - ONE STORY <br />INTERIOR ELEVATION MAXIMUM AREA 12,500 SF <br />�._ 4 A401 2 MARKERS ACTUAL AREA 9,300 SF <br />NORTH ARROW <br />SHEET NUMBER 3 - ELEVATION NUMBER <br />BRICK <br />+ , <br />G <br />CONCRETE <br />MASONRY <br />COMPACTED <br />������' <br />EARTH <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, <br />DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL <br />DIMENSIONS AND CONDITIONS. IF ANY DISCREPANCY OCCURS THE <br />CONTRACTOR SHALL NOTIFY THE ARC <br />HITECT CHITECT IN WRITING BEFORE <br />PROCEEDING WITH ANY WORK AFFECTED BY THE DISCREPANCY. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE A PROTECTION RE D S QUIRE DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID. <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. THE CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR <br />ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />GYPSUM <br />BOARD <br />RIGID <br />INSULATION <br />MR <br />BOARD <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED AND HAS <br />FLOW AND TAMPER FIRE ALARM MONITORING. THESE SYSTEMS <br />SHALL BE MODIFIED AS NEEDED TO PROVIDE FIRE PROTECTION <br />FOR THE SPECIFIED TENANT SPACES. THE CONTRACTOR SHALL <br />SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC <br />CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. NO <br />WORK ON THE FIRE PROTECTION SYSTEMS SHALL TAKE PLACE <br />UNTIL THE REQUIRED PERMITS ARE OBTAINED BY THE FIRE <br />PROTECTION SUB CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIRMENT S <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. SEE ENERGY CALCULATION ATTACHED TO THIS SUBMISSION <br />12. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />NOTE: <br />WIND ZONE = 110 MPH. IMPORTANCE FACTOR = 1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />ALL MODIFICATIONS TO THE EXTERIOR DOORS, THE EXTERIOR WINDOWS, <br />AND THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE <br />WITH THE APPLICABLE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />CLIENT: PRIMERICA GROUP ONE, INC. <br />3629 MADACA LANE <br />TAMPA, FL. 33618 <br />(813) 933-0629 PHONE <br />(813) 935-3420 FAX <br />CONTACT: ADAM ROBINSON <br />ARCHITECT: CUHACI & PETERSON, ARCHITECTS, LLC <br />1925 PROSPECT AVE <br />ORLANDO FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />CIVIL AVID GROUP <br />ENGINEER: 8659 BAYPINE ROAD, STE 304 <br />JACKSONVILLE, FLORIDA 32256 <br />(904) 737-4001 PHONE <br />(904) 252-7030 FAX <br />CONTACT: BOB PIERRO <br />CUHACI & PETERS <br />ON, ARCHITECTS,LL C <br />STRUCTURAL <br />ENGINEER: <br />19 <br />25 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: BRETT RYLANDS <br />MECHANICAL CUHACI <br />& PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECT AVE <br />ORLANDO,2 1 FL 3 8 4 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: JOE KEENE <br />ELECTRICAL CUHACI & PETERSON, ARCHITECTS, LLC <br />ENGINEER: 1925 PROSPECT AVE <br />ORLANDO, FL 32814 <br />(407) 661-9100 PHONE <br />(407) 661-9101 FAX <br />CONTACT: TIM NASH <br />Tenant Buildout for Spaces F I F3 & F4 <br />Building F at Zephyr Commons <br />78101781417818 & 7822 <br />Gall Blvd, Zephyrhills, FL <br />AREA OF INTERIOR WORK FOR F1-F3 <br />Scope of Work <br />1. THE SCOPE IS LIMITED TO TENANT SPACES F1-F3 & F4 IN BLDG F. <br />2. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE PARKING LOT, LANDSCAPING, SITE UTILITIES, <br />SITE DRAINAGE, SITE LIGHTING, OR ANY OTHER SITE FEATURES.. <br />3. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS IN THE SHOPPING CENTER OTHER <br />THAN BLDG F. <br />4. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE SIDEWALKS, HARDSCAPE AREAS, OR LANDSCAPE AEAS <br />IMMEDIATELY ADJACENT TO ANY OF THE BUILDINGS. <br />5. THE SCOPE INCLUDES REPLACING THE FABRIC ON THE TWO STRIPED AWNINGS TO MATCH THE TWO SOLID <br />AWNINGS, THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY OF THE OTHER FINISHES, STONE WORK, <br />OR DECORATIVE TRIM ON THE EXTERIOR ELEVATIONS OF ANY OF THE BUILDINGS. <br />6. THE SCOPE INCLUDES PROVIDING ONE NEW SINGLE STOREFRONT DOOR. IT INCLUDES REMOVING THREE <br />EXISTING SINGLE STOREFRONT DOORS AND REPLACING THEM WITH GLASS. IT INCLUDES REMOVING ONE <br />EXISTING SINGLE STOREFRONT DOOR AND REPLACING IT WITH A DOUBLE DOOR. THE SCOPE DOES NOT <br />INCLUDE ANY WORK TO ANY OF THE DECORATIVE WINDOWS. <br />7. THE SCOPE INCLUDES ADDING ONE HOLLOW METAL DOUBLE DOOR TO THE REAR OF THE BUILDING. IT <br />INCLUDES WELDING THREE OF THE EXISTING HOLLOW METAL DOORS SHUT. <br />8. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS <br />REQUIRED TO ADD EXHAUST FAN VENTS AND SANITARY VENTS FOR THE NEW RESTROOMS. THE SCOPE <br />DOES NOT INCLUDE ANY WORK ON THE SHINGLE ROOFS OR ON THE ROOF DRAINAGE SYSTEMS. <br />9. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE <br />NEW TENANT DEMISING WALLS. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED. <br />10. THE SCOPE INCLUDES ONE TENANT DEMISING WALL AND TWO STOCK ROOM WALLS. <br />11. THE SCOPE INCLUDES ADDING SHEATHING OVER METAL FURRING AND RIGID INSULATION ON THE INSIDE <br />OF SEVERAL OF THE MASONRY WALLS. <br />12. THE SCOPE INCLUDES INSTALLING THREE NEW RESTROOMS PER ADA REQUIRMENTS. <br />13. THE SCOPE INCLUDES INSTALLING ACT CEILINGS IN SPACE F4 AND IN THE RESTROOMS OF SPACE F1-F3. <br />THE REST OF SPACE F1-F3 WILL HAVE NO CEILING WITH THE STRUCTURE ABOVE PAINTED WHITE. <br />14. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF <br />DECK, OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK TO THE EXISTING LIGHT <br />GAUGE FRAMING. THE SCOPE INCLUDES PROVIDING A NEW MASONRY OPENING. <br />15. THE SCOPE DOES NOT INCLUDE ANY SAW -CUTTING OF THE EXISTING FLOOR SLAB. <br />16. THE SCOPE INCLUDES POURING A NEW SLAB IN THE AREA OF THE EXISTING SLAB LEAVEOUT. <br />17. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM WITH THE HEADS TURNED UP. THE SCOPE <br />INCLUDES MODIFYING THE SYSTEM AS NEEDED TO ACCOMODATE THE BUILD OUT. THE SCOPE INCLUDES <br />DESIGN AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S SPECIALTY ENGINEER THROUGH <br />HIS SHOP DRAWINGS. <br />18. THE SCOPE INCLUDES PROVIDING NEW SANITARY SERVICE, NEW VENT SYSTEM, AND NEW POTABLE <br />WATER SERVICE FOR THE RESTROOMS. <br />19. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY UNDERGROUND SANITARY LINES OTHER THAN WHAT <br />IS REQUIRED FOR CONNECTION OF THE NEW SANITARY LINES. THE SCOPE DOES NOT INCLUDE ANY <br />WORK TO ANY OF THE EXISTING CLEAN OUTS. <br />2 <br />C� <br />S bu t <br />14 <br />job <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUILDITI'G <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br />AREA OF INTERIOR WORK FOR F4 <br />L/D � <br />U <br />00 <br />N <br />M <br />� <br />� <br />o <br />0 <br />LL <br />� <br />Q <br />� <br />o <br />•U <br />C 7 <br />U <br />w <br />Cn <br />U _ <br />Cn <br />0 <br />Lo <br />CN <br />20. THE SCOPE INCLUDES REMOVAL OF ANY UNUSED PORTION OF EXISTING ABOVE GROUND STUB INS. <br />21. THE SCOPE DOES NOT INCLUDE ANY FLOOR DRAINS OR ANY STUB OUTS FOR FUTURE CONNECTION TO <br />THE SANITARY OR VENT SYSTEMS. <br />22. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE WATER METER, THE 1" COLD WATER MAIN, OR ANY OF <br />THE VALVES. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE 1" COLD WATER BRANCH LINES OTHER <br />THAN WHAT IS REQUIRED FOR CONNECTION OF THE NEW COLD WATER PIPING. <br />23. THE SCOPE INCLUDES INSTALLING SUB METERS PROVIDED BY THE OWNER. <br />24. THE SCOPE DOES NOT INCLUDE ANY PROVISIONS FOR HOT WATER OR ANY STUB OUTS OR VALVES FOR <br />FUTURE CONNECTION TO THE COLD WATER SYSTEM. <br />25. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS OR GREASE. <br />26. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE EXISTING RTUS OTHER THAN WHAT IS REQUIRED TO <br />CONNECT NEW HVAC DUCTING. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE CONDENSATE LINES. <br />27. THE SCOPE INCLUDES PROVIDING A FULL HVAC SYSTEM. <br />28. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER, SECONDARY CONDUIT, +G� z <br />SECONDARY WIRE, MAIN DISCONNECT, WIREWAY, TENANT METERS OR TENANT DISCONNECTS. > CD <br />m 6' <br />29. THE SCOPE INCLUDES PROVIDING ONE NEW 200 AMP TENANT PANEL AND ONE NEW 400 AMP TENANT 0� d Q <br />� <br />PANEL. THE NEW TENANT PANELS SHALL BE CONNECTED TO THE EXISTING DISCONNECTS VIA NEW WIRE z It <br />PULLED THROUGH THE EXISTING EMPTY CONDUITS. > U_ <br />Uj <br />30. THE SCOPE INCLUDES PROVIDING NEW POWER RECEPTACLES WIRED TO THE TENANT PANEL. "' <br />31. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING SIGN JUNCTION BOXES ON THE FRONT <br />OF THE BUILDING. THE SCOPE INCLUDES WIRING SEVERAL OF THESE JUNCTION BOXES TO THE TENANT <br />PANELS. <br />32. THE SCOPE INCLUDES WIRING THE EXISTING RTUS AND ALL OTHER COMPONENTS OF THE HVAC SYSTEM <br />TO THE TENANT PANELS. <br />33. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE SCONCE FIXTURES ON THE FRONT OF THE <br />BUILDING OR THEIR WIRING. p� <br />34. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING WALL MOUNTED LIGHT FIXTURES ON <br />THE REAR OF THE BUILDING OTHER THAN WIRING THEM TO THE TENANT PANELS VIA LIGHT SWITCHES. <br />I <br />35. THE SCOPE INCLUDES NEW EXIT AND EMERGENCY LIGHTING THAT WILL BE WIRED TO THE NEW TENANT �--� <br />ELECTRICAL PANELS. <br />36. THE SCOPE INCLUDES PROVIDING NEW FLUORESCENT LIGHT FIXTURES WIRED TO THE TENANT <br />ELECTRICAL PANELS. THE SCOPE INCLUDES LAY IN LIGHT FIXTURES IN AREAS WITH CEILINGS AND V 0 <br />SUSPENDED LIGHT FIXTURES IN AREAS WITHOUT CEILINGS. cC�i <br />37. THE SCOPE DOES NOT INCLUDE ANY CHANGES TO THE EXISTING TELEPHONE STUB INS THAT WILL <br />REMAIN FOR FUTURE TENANT USE. THE SCOPE DOES INCLUDE REMOVAL OF THE ABOVE GROUND O <br />PORTIONS OF THE CONDUITS THAT WILL NOT BE USED BY THE FUTURE TENANT. O <br />38. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM A <br />NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE FIRE <br />ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS. <br />04EVIEW DATE J/-S 0 X/ <br />91TY OF 2EPHYRHILL <br />� UAM1NER `�� <br />�C -G f ' L/✓'l�i i�-I ct <br />Drawing Index <br />PERMIT SET REVI <br />SHEET N0. TITLE ON SHEET 2009_10-30 2009 <br />) <br />�MM <br />3ION1 <br />_12-07 <br />----- <br />ARCHITECTURAL <br />A000 COVER SHEET X; i I - <br />A100 , PROJECT SITE PLAN _ _ X <br />A101- LIFE SAFETY PLAN_- T X X I ; <br />-- <br />A103 _._ REFLECTDNCEILING PLAN _ X X <br />�. rf <br />Al04 .__ DETAILS I X <br />A001-AO04 :. SPECIFICATIONS _ X <br />FIRE PROTECTION _ <br />I, <br />3 <br />I <br />FIRE PROTECTION NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED TO ACCOMODATE THE TENANT BUILD OUT. ALL MODIFICATIONS TO THE SYSTEM <br />SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED & SEALED SHOP DRAWINGS & HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING <br />P101 - PLUMBING GENERAL INFO, FLOOR PLAN & RISERS T X <br />MECHANICAL <br />M101 n MECHANICAL GENERAL INFORMATION & FLOOR PLAN X ®- <br />- <br />_.... ..._. i,.._. ,..-_.-......_...._.......,...,...-...._. € _..- ..gym,._... C 1...-..._.-._... <br />ELECTRICAL <br />W. EXX <br />( ` <br />I E101 ELECTRICAL POWER PLAN <br />E 201 ELECTRICAL LIGHTING PLAN E501 ELECTRICAL SPECIFICATIONS <br />S <br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED TO ACCOMODATE THE TENANT BUILD OUT. ALL MODIFICATIONS TO THE <br />FIRE ALARM SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />