Laserfiche WebLink
City of Zephyrhills Review Comments/ Construction <br />Requirements <br />Compaction Tests will be required per 2004 Florida Building Code chapterl 8. <br />Separate permits and additional data will be required for installation of fuel gas <br />appliances, fire suppression systems, commercial hood systems, fire alarms and elevators <br />per 2004 Florida Building Code section 106. <br />Health Department review and approval will be required prior to the issuance of a <br />building permit. <br />Emergency egress windows required shall comply with 2004 Florida building Code <br />section 1025. <br />Balcony guardrails shall be 42"inches in height per 2004 Florida building Code section <br />1012. <br />Water heater installation shall comply with 2004 Florida Building/Plumbing Code <br />chapter 5 and also chapter 6 (thermal expansion). <br />Installation of kitchen fixtures and appliances shall comply with 2004 Florida <br />Building/Plumbing Code chapter 8. <br />Cable and conduit installation shall comply with 2005 National Electric Code article <br />#518. <br />All bedrooms outlets shall be arc fault protected per 2005 National Electric Code article <br />#210.12 <br />Smoke detectors in dwelling units shall comply with 2004 Florida Building Code # <br />907.2.10.1. <br />Field inspections may result in the imposition of codes and requirements not <br />specifically noted.. <br />REV IFW OATE:Aqjz�j_ <br />�;�T. �.. <br />