My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39906 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39906 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:13:00 AM
Creation date
2/19/2025 4:13:36 PM
Metadata
Fields
Template:
Building Plans
Street #
39906
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1755
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MA <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN MONO <br />7 <br />ROOF FRAMING PLAN <br />8 LINTEL PLAN AND DETAILS <br />SN STRUCTURAL NOTES <br />ABBREVIATIONS SN1 DETAILS <br />AB or A.B. Anchor Bolt FIX or FXD Fixed PWDR or Pwd. Powder Room <br />S31VI MONO DETAILS <br />ABV or Abv. Above FLR or Fir. Floor RA or R/A or R.A. Return Air S4 DETAILS <br />AC or A/C Air -Conditioner FLR SYS or Ar Sys Floor System RAO or Rad. Radius S5 DETAILS <br />ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry RAG or Rag. Return Air Grill, _ <br />AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace REC or Rec. Recessed r -r SS RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit FR DR French Door RECEPT Receptacle D1 SECTIONS &DETAILS <br />ALT or ALT. Alternate FRT Front REF or Ref. Refrigerator —__ <br />BC Base Cabinet FT or Ft. Foot/ Feet REINF Reinforcing -- -- — WP WATERPROOFING DETAILS <br />BF Bifold Door FTG or Fig. Footing REQD or Req'd. Required <br />BK SH or Bk Sh BookShelf FXD GL Fixed Glass RM or Rm. Room T� T T PA1.0 PRODUCT APPROVAL NUMBERS <br />BLK or BLK. Block GALV or Galy. Galvanized RND or Rnd. Round _ - PA1.1 PRODUCT APPROVAL NUMBERS <br />BLW or BLW. Below GC or G.C. General Contractor RO or R.O. Rough Opening _ T T_ � _L �L� — <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter RS, R/S, R/SH or R&S Rod and Shelf 1.2 PRODUCT APPROVAL NUMBERS <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SO. Smoke Detector <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves — -- -- -- _ — <br />C Carpet HDR or Hdr. Header SHT Sheet - _ _ _ — _ _ <br />CAB Cabinet HGT or Hgt. Height SHWR or Shwr. Shower <br />CIR or Cir. Circle HH or H.H. Hand Held (plumbing faucet) SL or S.L. Side Lights <br />CJ or or r Control Joint HHorizontal SPECS SPECS. Specifications [710[:1171 F <br />CLG Clg. Ceiling HS Hard Surface (flooring) SPF or S.. P.F. Spruce Pine Fir <br />CMU Concrete Masonry Unit ILO In Lieu Of SQ or SF or S.F. Square Foot (feet) 01:1EIME17 ElCOFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SQ or Sqq . Square <br />COL or Col. Column INT or Int. Interior STO Storage <br />COMM or Comm. Community KSor K.S.K/Wall Knee Sp SW or S.W. Shear Wall F11 � ICJ El D <br />COMP or Comp. Compressor KS or K.. Knee Space SYP or S.Y.P. Southern Yellow Pine <br />0 El <br />CONN or CONN. Connection LAUN or Laun. Laundry TB Towel Bar <br />CONT or Cont. Continuous LAV or Lay. Lavatory TEMP or Temp. Tempered ❑ ❑ ❑ FE7 <br />❑ [1:7:1 <br />M <br />❑ <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. THIKN or Thik'n. Thicken <br />D or D. Dryer LL Lintel Length TOB or T,O.B. Top of Block <br />DB Door Bell LT Laundry Tub TOM or T.O.M. Top of Masonry <br />DBL or Dbl. Double MAS or Mas. Masonry TOP or T.O.P. Top of Plate <br />DCF Decorative Cementitious Finish MAX or Max Maximum TP Toilet Paper Holder <br />DEC or Dec. Decorative MC Medicine Cabinet TR Towel Ring <br />DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TRANS WOW or Trans. Transom Window <br />DIA or Dia. Diameter MGT Management (room) TYP or Typ. Typical <br />DISP or Disp. Disposal MIN or Min Minimum UC or u.c. Under Counter <br />DIST or Dist. Distance MIR or Mir. Mirror UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish ML or M.L. Microlam UNO or U.N.O. Unless Noted Otherwise <br />DS or D.S. Drawer Stack MONO or Mono Monolithic V or v. Valve (shower or tub/shower) <br />DTL Detail MW or MICRO or Micro. Microwave VB Vanity Base <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VERT or Vert. Vertical <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VL or V.L. Versalam <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening VTR or VTE Vent through Roof / Exterior <br />EA or Ea. Each OPT or Opt Optional W or w Washer <br />ELEC or Elec. Electrical PC Pull Chain W/ or w/ With <br />ELEV or Elev. Elevation PED or Ped. Pedestal WA or W.A. Wedge Anchor <br />EQ Equal PH Phone WC or WIC or W.C. Water Closet (toilet) <br />EW or E.W. Each Way PKT or Pkt. Pocket (Door) WD or Wd Wood <br />EXP or Exp. Expansion PL or P.L. Parallam WDW HDR or WOW. HDR. Window Header <br />EXT or Ext. Exterior PLF Pounds per linear foot WH or W.H. Water Heater <br />FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WIC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation PLT HT or Pit. Ht. Plate Height WM or W.M. Wall Mounted (plumbing fixture) <br />FG Fiberglass (Shower Pan) PSF Pounds per square foot WP WaterProof(ing) MEAN ROOF 15 FT. HIGH TYPICAL <br />FIN Finished PT or P.T. Pressure Treated WS Water Softener FOR SINGLE STORY HOMES <br />FIN FLR or FF or Fin. Fir. Finished Floor PW or P.W, Pre -wire WWF Welded Wire Fabric (Mesh) <br />REVISIONS <br />P A N MEAN ROOF 30 FT. HIGH TYPICAL <br />DATE VERSION DESCRIPTION FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />08-20-1 5 1.0 NEW BASE PLAN FOR 12 MONTHS AFTER THE DATE 1T <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT <br />12-8-15 2.0 FRAME —WALK REVISIONS - <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />1 2-27-1 7 3.0 2017 FBC UPDATES SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />05-20-19 3.1 ELEV. Al - REVISED BANDS BACK TO <br />Notice to Builder &All Subcontractors <br />ORIGINAL DESIGN It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />08-2 7-19 3.2 E N G . REVIEW FOR 150-C MPH Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />09-20-19 3.3 ADD 8'-8" ELEV. FOR T R EV E STA the commencement of any work. The DesignerEngineercrre not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />05-14-20 3.4 ELEV. B REV. ENTRY PER M.K. information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />12-15-20 3.5 OVERHANG OVER SGD REV. TO 3' PER C.M. considered for reimbursement by the Designer/Engineerwithout <br />advanced notification and approval by the Designer/Engineer. <br />Im IE Fq rq ri Payments will be made in accordance to the terms of the <br />agreement. <br />12-19-20 4.0 FBC 2020 CODE UPDATE <br />Control of Construction Site: <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />1 551 vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />CV <br />0 <br />CV <br />0 ��� o <br />c No PE78750 <br />w <br />a <br />-00 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />�E <br />AgaQ O S 3 <br />fi00 <br />r` <br />N # <br />� <br />� <br />ry <br />v '� l2') Oo N <br />* L. W <br />a <br />�r-1 <br />� �mv <br />w <br />LL a. <br />vi vYi <br />J U_LL <br />a U <br />0 <br />Z _�,� <br />X <br />O <br />N co <br />0 <br />0 <br />VJ U5 c� O) <br />¢ Q <br />N CO <br />IL <br />Of D 0 <br />0 U <br />U N <br />z <br />oa❑ <br />V M <br />I � o <br />z <br />J <br />N <br />try <br />ai <br />LL <br />Kn <br />♦� lL! two <br />V <br />Oru SJuMft <br />N � w <br />un <br />tiles, <br />1.3�r J <br />E <br />8 <br />� z w <br />(} o <br />cQ oe <br />401 <br />o <br />w <br />co <br />o <br />o <br />7d <br />E <br />z© <br />w° <br />a= <br />°� <br />co <br />Xo <br />U <br />¢F <br />uo <br />0 <br />OQ <br />Nao <br />wW <br />U <br />_ C <br />oY <br />b <br />~O� <br />z <br />IL <br />� <br />0) <br />co <br />< <br />Z <br />noo <br />N <br />of <br />LL <br />�w <br />o� <br />r3 <br />o <br />a <br />.0� <br />J <br />> <br />O <br />C <br />CD <br />m <br />0 <br />U <br />O <br />> <br />O <br />C) <br />CL <br />� <br />IL <br />C m <br />O <br />r <br />T_ <br />co O <br />Lo <br />2 N <br />j— <br />LO <br />CD 0 <br />r= <br />N rn N <br />r <br />p n' <br />E <br />3 N <br />Z <br />Z <br />N <br />E CO at <br />M <br />a <br />E _0 ai <br />U _J ¢ p <br />c <br />_J <br />JOB <br />NO: 21-2025 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />—1_T 1 d FF-, T_ I <br />
The URL can be used to link to this page
Your browser does not support the video tag.