Laserfiche WebLink
mm <br />W1 IV <br />MiTek' <br />RE: TTH126-132 MiTek USA, Inc. <br />16023 Swingley Ridge Rd <br />Chesterfield, MO 63017 <br />Site Information: <br />Customer: Starligght Homes Project Name: TTH126-132 <br />Lot/Block: 126-T32 Model: 7 Plex <br />Address: . Subdivision: Tyson <br />City: Zephyrhills State: Florida <br />General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special <br />Loading Conditions): <br />Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.6 <br />Wind Code: ASCE 7-16 Wind Speed: 150 mph <br />Roof Load: 37.0 psf Floor Load: N/A psf <br />This package includes 32 individual, dated Truss Design Drawings and 0 Additional Drawings. <br />With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet <br />conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. <br />No. <br />Seal# <br />Truss Name <br />Date <br />No. <br />Seal# <br />Truss Name <br />Date <br />1 <br />T30641470 <br />C 1 A <br />5/25/2023 <br />21 <br />T30641490 <br />T11 <br />5/25/2023 <br />2 <br />T30641471 <br />C3A <br />5/25/2023 <br />22 <br />T30641491 <br />Vol <br />5/25/2023 <br />3 <br />T30641472 <br />CJ 1 <br />5/25/2023 <br />23 <br />T30641492 <br />V02 <br />5/25/2023 <br />4 <br />T30641473 <br />CJ3 <br />5/25/2023 <br />24 <br />T30641493 <br />V03 <br />5/25/2023 <br />5 <br />T30641474 <br />EJ5 <br />5/25/2023 <br />25 <br />T30641494 <br />VO4 <br />5/25/2023 <br />6 <br />T30641475 <br />HJ5 <br />5/25/2023 <br />26 <br />T30641495 <br />V05 <br />5/25/2023 <br />7 <br />T30641476 <br />T01 <br />5/25/2023 <br />27 <br />T30641496 <br />V06 <br />5/25/2023 <br />8 <br />T30641477 <br />T02 <br />5/25/2023 <br />28 <br />T30641497 <br />V07 <br />5/25/2023 <br />9 <br />T30641478 <br />T03 <br />5/25/2023 <br />29 <br />T30641498 <br />V08 <br />5/25/2023 <br />10 <br />T30641479 <br />T04 <br />5/25/2023 <br />30 <br />T30641499 <br />V09 <br />5/25/2023 <br />11 <br />T30641480 <br />T04A <br />5/25/2023 <br />31 <br />T30641500 <br />V10 <br />5/25/2023 <br />12 <br />T30641481 <br />T05 <br />5/25/2023 <br />32 <br />T30641501 <br />V11 <br />5/25/2023 <br />13 <br />T30641482 <br />T05A <br />5/25/2023 <br />14 <br />T30641483 <br />T06 <br />5/25/2023 <br />15 <br />T30641484 <br />T06A <br />5/25/2023 <br />16 <br />T30641485 <br />T07 <br />5/25/2023 <br />17 <br />T30641486 <br />T07A <br />5/25/2023 <br />18 <br />T30641487 <br />T09 <br />5/25/2023 <br />19 <br />T30641488 <br />T10 <br />5/25/2023 <br />20 <br />T30641489 <br />T10A <br />5/25/2023 <br />This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. <br />Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies <br />The truss drawing(s) referenced above have been prepared by <br />MiTek USA, Inc under my direct supervision %%01 11 t r lli l l,,��� <br />based on the parameters provided by Builders FirstSource - Plant City. % op�CLOIN VF�� <br />Truss Design Engineer's Name: Velez, Joaquin�..���C E N <br />My license renewal date for the state of Florida is February 28, 2025. <br />Florida COA: 6634 No 68182 <br />IMPORTANT NOTE: The seal on these truss component designs is a certification <br />that the engineer named is licensed in the jurisdiction(s) identified and that the <br />designs comply with ANSI/TPI 1. These designs are based upon parameters <br />shown (e.g., loads, supports, dimensions, shapes and design codes), which were <br />given to MiTek. Any project specific information included is for MiTek <br />customers file reference purpose only, and was not taken into account in the preparation of <br />these designs. MiTek has not independently verified the applicability of the design <br />parameters or the designs for any particular building. Before use, the building designer <br />should verify applicability of design parameters and properly incorporate these designs <br />into the overall building design per ANSI/TPI 1, Chapter 2. <br />�-33 ' STATE OF .' 41/ <br />. <br />.0R� Cam. <br />1111111100 <br />Joaquin Velez PE No.68182 <br />3lrrek Inc. DHA MiTek USA FL Cert 6634 <br />16023 Swingle, Ridge Rd. Chesterfield, NIO 63017Dow May 25, 2023 <br />1 of 1 Velez, Joaquin <br />