My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Elby Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
Elby Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:37:16 PM
Creation date
2/18/2025 4:52:41 PM
Metadata
Fields
Template:
Building Plans
Location
Elby Ln
Contractor
Starlight Homes
Description
Tyson 7 Plex
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lip <br />MiTek' <br />RE: TTH27-33 - <br />Site Information: <br />Customer Info: Starlight Homes <br />Lot/Block: 27-33 <br />Address: ., . <br />City: Zephyrhills <br />Lumber design values are in accordance with ANSI/TPI 1 section 6.3 <br />These truss designs rely on lumber values established by others. <br />Project Name: TTH27-33 Model: 7 Plex <br />Subdivision: Tyson <br />State: Florida <br />MiTek USA, Inc. <br />16023 Swingley Ridge Rd <br />Chesterfield, MO 63017 <br />Name Address and License # of Structural Engineer of Record, If there is one, for the building. <br />Name: License #: <br />Address: <br />City: State: <br />General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special <br />Loading Conditions): <br />Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.6 <br />Wind Code: ASCE 7-16 Wind Speed: 150 mph <br />Roof Load: 37.0 psf Floor Load: N/A psf <br />This package includes 32 individual, Truss Design Drawings and 0 Additional Drawings. <br />With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet <br />conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. <br />No. <br />Seal# <br />Truss Name <br />Date <br />No. <br />Seal# <br />Truss Name <br />Date <br />1 <br />T30850233 <br />C1A <br />6/20/23 <br />15 <br />T30850247 <br />T06A <br />6/20/23 <br />2 <br />T30850234 <br />C3A <br />6/20/23 <br />16 <br />T30850248 <br />T07 <br />6/20/23 <br />3 <br />T30850235 <br />CA <br />6/20/23 <br />17 <br />T30850249 <br />T07A <br />6/20/23 <br />4 <br />T30850236 <br />CJ3 <br />6/20/23 <br />18 <br />T30850250 <br />T09 <br />6/20/23 <br />5 <br />T30850237 <br />EJ5 <br />6/20/23 <br />19 <br />T30850251 <br />T10 <br />6/20/23 <br />6 <br />T30850238 <br />HJ5 <br />6/20/23 <br />20 <br />T30850252 <br />T10A <br />6/20/23 <br />7 <br />T30850239 <br />T01 <br />6/20/23 <br />21 <br />T30850253 <br />T11 <br />6/20/23 <br />8 <br />T30850240 <br />T02 <br />6/20/23 <br />22 <br />T30850254 <br />V01 <br />6/20/23 <br />9 <br />T30850241 <br />T03 <br />6/20/23 <br />23 <br />T30850255 <br />V02 <br />6/20/23 <br />10 <br />T30850242 <br />T04 <br />6/20/23 <br />24 <br />T30850256 <br />V03 <br />6/20/23 <br />11 <br />T30850243 <br />T04A <br />6/20/23 <br />25 <br />T30850257 <br />VO4 <br />6/20/23 <br />12 <br />T30850244 <br />T05 <br />6/20/23 <br />26 <br />T30850258 <br />V05 <br />6/20/23 <br />13 <br />T30850245 <br />T05A <br />6/20/23 <br />27 <br />T30850259 <br />V06 <br />6/20/23 <br />14 <br />T30850246 <br />T06 <br />6/20/23 <br />28 <br />T30850260 <br />V07 <br />6/20/23 <br />This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. <br />Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies <br />The truss drawing(s) referenced above have been prepared by <br />MiTek USA, Inc. under my direct supervision based on the parameters <br />provided by Builders FirstSource - Plant City. <br />Truss Design Engineer's Name: Velez, Joaquin <br />My license renewal date for the state of Florida is February 28, 2025. <br />IMPORTANT NOTE: The seal on these truss component designs is a certification <br />that the engineer named is licensed in the jurisdiction(s) identified and that the <br />designs comply with ANSI/TPI 1. These designs are based upon parameters <br />shown (e.g., loads, supports, dimensions, shapes and design codes), which were <br />given to MiTek or TRENCO. Any project specific information included is for MiTek's or <br />TRENCO's customers file reference purpose only, and was not taken into account in the <br />preparation of these designs. MiTek or TRENCO has not independently verified the <br />applicability of the design parameters or the designs for any particular building. Before use, <br />the building designer should verify applicability of design parameters and properly <br />incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. <br />`,1111 a 1111��� <br />PQU I N V ., <br />No 68182 <br />=-v: �x: <br />STATE OF 4J <br />sS�ONA\-e%%o• <br />�41►111111"t <br />Joaquin VcIc, PE 1o.68182 <br />MiTek Inc. DB.1 MiTek IS9 FL Cert 6634 <br />16023 Swingley Ridge Rd. Chesterfield. MO 63017 <br />Date: <br />June 20,2023 <br />Velez, Joaquin 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.